Literature DB >> 31926489

Efficacy of a hydrogel spacer in three-dimensional conformal radiation therapy for prostate cancer.

Mami Ogita1, Hideomi Yamashita1, Subaru Sawayanagi1, Wataru Takahashi1, Keiichi Nakagawa1.   

Abstract

OBJECTIVES: We aimed to compare the dose constraints fulfillment rate of the three-dimensional conformal radiotherapy treatment plan before and after a hydrogel spacer insertion.
METHODS: The planning computed tomography scans of 39 patients who received stereotactic body radiotherapy for prostate cancer were used. All patients inserted a hydrogel spacer and underwent computed tomography scans before and after spacer insertion. The three-dimensional conformal radiotherapy plans according to NCCN classification, low-, intermediate- and high-risk, were made for each patient. Clinical target volume included prostate and seminal vesicle 2 cm for high risk, prostate and seminal vesicle 1 cm for intermediate risk and prostate only for low risk. Three-dimensional conformal radiotherapy including a seven-field conformal technique with 76 Gy in 38 fractions. Dose constraints for rectum and bladder were V70 Gy ≤ 15%, V65 Gy ≤ 30% and V40 Gy ≤ 60%.
RESULTS: Among 39 patients, 35 (90%), 19 (49%) and 13 (33%) and 38 (97%), 38 (97%) and 34 (87%) patients before and after the spacer insertion fulfilled rectum dose constraints for low-, intermediate- and high-risk plans, respectively. A hydrogel spacer significantly reduced rectum dose and improved the rectum dose constraints fulfillment rate in intermediate (P < 0.01) and high (P < 0.01), but no difference was found in low-risk plan (P = 0.25). On multivariate analysis, spacer use was associated with the higher rectum dose constraints fulfillment rate.
CONCLUSIONS: A hydrogel spacer reduced rectum dose and improved the dose constraints fulfillment rate in three-dimensional conformal radiotherapy plan. Although IMRT is the standard treatment, 3D-CRT using a hydrogel spacer may be a treatment option.
© The Author(s) 2020. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

Entities:  

Keywords:  3D conformal radiotherapy; hydrogel; prostate cancer; radiation therapy

Mesh:

Substances:

Year:  2020        PMID: 31926489     DOI: 10.1093/jjco/hyz171

Source DB:  PubMed          Journal:  Jpn J Clin Oncol        ISSN: 0368-2811            Impact factor:   3.019


  3 in total

1.  Preliminary analysis of prostate positional displacement using hydrogel spacer during the course of proton therapy for prostate cancer.

Authors:  Hiroki Sato; Takahiro Kato; Tomoaki Motoyanagi; Kimihiro Takemasa; Yuki Narita; Masato Kato; Takuya Matsumoto; Sho Oyama; Hisashi Yamaguchi; Hitoshi Wada; Masao Murakami
Journal:  J Radiat Res       Date:  2021-03-10       Impact factor: 2.724

Review 2.  Employing hydrogels in tissue engineering approaches to boost conventional cancer-based research and therapies.

Authors:  Javad Esmaeili; Abolfazl Barati; Jafar Ai; Vajihe Taghdiri Nooshabadi; Zeynab Mirzaei
Journal:  RSC Adv       Date:  2021-03-12       Impact factor: 3.361

3.  Quality of life after definitive linear accelerator-based stereotactic radiotherapy for prostate cancer: a longitudinal study.

Authors:  Hideomi Yamashita; Mami Ogita; Subaru Sawayanagi; Yuki Nozawa; Osamu Abe
Journal:  Radiat Oncol       Date:  2022-05-12       Impact factor: 3.481

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.