Yoshinobu Onuma1, Yasuhiro Honda2, Taku Asano3, Hiroki Shiomi4, Ken Kozuma5, Yukio Ozaki6, Atsuo Namiki7, Satoshi Yasuda8, Takafumi Ueno9, Kenji Ando10, Jungo Furuya11, Keiichi Igarashi Hanaoka11, Kengo Tanabe12, Kozo Okada2, Hideki Kitahara2, Masafumi Ono3, Hajime Kusano13, Richard Rapoza13, Charles Simonton13, Jeffrey J Popma14, Gregg W Stone15, Peter J Fitzgerald2, Patrick W Serruys16, Takeshi Kimura17. 1. Thoraxcenter, Erasmus MC, Rotterdam, the Netherlands; Cardialysis, Rotterdam, the Netherlands. 2. Stanford Cardiovascular Institute, Stanford, California. 3. Cardialysis, Rotterdam, the Netherlands; Academic Medical Center, Amsterdam, the Netherlands. 4. Kyoto University Hospital, Kyoto, Japan. 5. Teikyo University Hospital, Tokyo, Japan. 6. Fujita Health University Hospital, Toyoake, Japan. 7. Kanto Rosai Hospital, Kawasaki, Japan. 8. National Cerebral and Cardiovascular Center, Osaka, Japan. 9. Kurume University School of Medicine, Kurume, Japan. 10. Division of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan. 11. Hanaoka Seishu Memorial Cardiovascular Clinic, Hokkaido, Japan. 12. Mitsui Memorial Hospital, Tokyo, Japan. 13. Abbott Vascular, Santa Clara, California. 14. Beth Israel Deaconess Medical Center, Boston, Massachusetts. 15. Columbia University Medical Center, NewYork-Presbyterian Hospital, and the Cardiovascular Research Foundation, New York, New York. 16. International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London, London, United Kingdom. 17. Kyoto University Hospital, Kyoto, Japan. Electronic address: taketaka@kuhp.kyoto-u.ac.jp.
Abstract
OBJECTIVES: The aim of this study was to investigate the vascular responses and fates of the scaffold after bioresorbable vascular scaffold (BVS) implantation using multimodality imaging. BACKGROUND: Serial comprehensive image assessments after BVS implantation in the context of a randomized trial have not yet been reported. METHODS: In the ABSORB Japan trial, 400 patients were randomized to a BVS (n = 266) or a cobalt-chromium everolimus-eluting stent (n = 134). Through 3 years, patients underwent serial angiography and intravascular ultrasound or optical coherence tomography (OCT). RESULTS:Luminal dimension at 3 years was consistently smaller with the BVS than with the cobalt-chromium everolimus-eluting stent (mean angiographic minimal luminal diameter 2.04 ± 0.63 mm vs. 2.40 ± 0.56 mm, mean difference -0.37 mm [95% confidence interval: -0.50 to -0.24 mm]; p < 0.001), mainly because of smaller device area (6.13 ± 2.03 mm2 vs. 7.15 ± 2.16 mm2, mean difference -1.04 mm2 [95% confidence interval: -1.66 to -0.42 mm2]; p < 0.001), and larger neointimal area (2.10 ± 0.61 mm2 vs. 1.86 ± 0.64 mm2, mean difference 0.24 mm2 [95% confidence interval: 0.06 to 0.43 mm2]; p = 0.01) by OCT. BVS-treated vessels did not show previously reported favorable vessel responses, such as positive vessel remodeling, late luminal enlargement, and restoration of vasomotion, although the OCT-based healing score was on average zero (interquartile range: 0.00 to 0.00). At 3 years, intraluminal scaffold dismantling (ISD) was observed in 14% of BVS. On serial OCT, ISD was observed in 6 lesions at 2 years, where the struts had been fully apposed at post-procedure, while ISD was observed in 12 lesions at 3 years, where 8 lesions were free from ISD on 2-year OCT. In 5 cases of very late scaffold thrombosis, strut discontinuities were detected in all 4 cases with available OCT immediately before reintervention. CONCLUSIONS: In this multimodality serial imaging study, luminal dimension at 3 years was smaller with the BVS than with the cobalt-chromium everolimus-eluting stent. ISD, suspected to be one of the mechanisms of very late BVS thrombosis, was observed in a substantial proportion of cases at 3 years, which developed between post-procedure and 2 years and even beyond 2 years. (AVJ-301 Clinical Trial: A Clinical Evaluation of AVJ-301 [Absorb™ BVS] in Japanese Population [ABSORB JAPAN]; NCT01844284).
RCT Entities:
OBJECTIVES: The aim of this study was to investigate the vascular responses and fates of the scaffold after bioresorbable vascular scaffold (BVS) implantation using multimodality imaging. BACKGROUND: Serial comprehensive image assessments after BVS implantation in the context of a randomized trial have not yet been reported. METHODS: In the ABSORB Japan trial, 400 patients were randomized to a BVS (n = 266) or a cobalt-chromium everolimus-eluting stent (n = 134). Through 3 years, patients underwent serial angiography and intravascular ultrasound or optical coherence tomography (OCT). RESULTS: Luminal dimension at 3 years was consistently smaller with the BVS than with the cobalt-chromium everolimus-eluting stent (mean angiographic minimal luminal diameter 2.04 ± 0.63 mm vs. 2.40 ± 0.56 mm, mean difference -0.37 mm [95% confidence interval: -0.50 to -0.24 mm]; p < 0.001), mainly because of smaller device area (6.13 ± 2.03 mm2 vs. 7.15 ± 2.16 mm2, mean difference -1.04 mm2 [95% confidence interval: -1.66 to -0.42 mm2]; p < 0.001), and larger neointimal area (2.10 ± 0.61 mm2 vs. 1.86 ± 0.64 mm2, mean difference 0.24 mm2 [95% confidence interval: 0.06 to 0.43 mm2]; p = 0.01) by OCT. BVS-treated vessels did not show previously reported favorable vessel responses, such as positive vessel remodeling, late luminal enlargement, and restoration of vasomotion, although the OCT-based healing score was on average zero (interquartile range: 0.00 to 0.00). At 3 years, intraluminal scaffold dismantling (ISD) was observed in 14% of BVS. On serial OCT, ISD was observed in 6 lesions at 2 years, where the struts had been fully apposed at post-procedure, while ISD was observed in 12 lesions at 3 years, where 8 lesions were free from ISD on 2-year OCT. In 5 cases of very late scaffold thrombosis, strut discontinuities were detected in all 4 cases with available OCT immediately before reintervention. CONCLUSIONS: In this multimodality serial imaging study, luminal dimension at 3 years was smaller with the BVS than with the cobalt-chromium everolimus-eluting stent. ISD, suspected to be one of the mechanisms of very late BVS thrombosis, was observed in a substantial proportion of cases at 3 years, which developed between post-procedure and 2 years and even beyond 2 years. (AVJ-301 Clinical Trial: A Clinical Evaluation of AVJ-301 [Absorb™ BVS] in Japanese Population [ABSORB JAPAN]; NCT01844284).