Unreliability of oxygen tension-based indices in reflecting intrapulmonary shunting in critically ill patients.

R D Cane1, B A Shapiro, R Templin, K Walther.   

Abstract

Measurement of intrapulmonary shunting (Qsp/Qt), a widely used method for monitoring disturbances of pulmonary oxygen transfer in critically ill patients, involves calculation of arterial and mixed venous oxygen contents. In circumstances where mixed venous blood samples are not readily available, oxygen tension-based indices such as the alveolar to arterial oxygen tension differences (P[A-a]O2), arterial oxygen tension to alveolar oxygen tension ratio (PaO2/PAO2), PaO2 to FIO2 ratio (PaO2/FIO2) and respiratory index (RI) are widely utilized to reflect Qsp/Qt. Oxygen content-based indices such as the estimated shunt are not as widely utilized as the oxygen tension indices. In 75 critically ill patients in whom a pulmonary artery catheter was being utilized to augment clinical care, comparisons were made between Qsp/Qt and P(A-a)O2, PaO2/PAO2, PaO2/FIO2, RI, and estimated shunt to determine which index best reflected Qsp/Qt. Correlations between Qsp/Qt and estimated shunt were good (r = .94) and poor for the P(A-a)O2 (r = .62), PaO2/PAO2 (r = .72), PaO2/FIO2 (r = .71), and RI (r = .74). We conclude that there are no real substitutes for venous oxygen contents in critically ill patients. When pulmonary artery blood is not available for analysis, oxygen tension-based indices are unreliable reflectors of Qsp/Qt while the estimated shunt, an oxygen content-based index, provides a more reliable reflection of Qsp/Qt.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3191742     DOI: 10.1097/00003246-198812000-00014

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  7 in total

Review 1.  Practical points in the application of oxygen transport principles.

Authors:  P Nightingale
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

2.  Computerized blood gas interpretation as tool for classroom and ICU.

Authors:  A Frutiger; J X Brunner
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

3.  Pulmonary oxygen transfer deficits of diabetic origin in patients undergoing coronary artery bypass grafting.

Authors:  S Seki; H Yoshida; O Ooba; S Teramoto; Y Komoto
Journal:  Surg Today       Date:  1993       Impact factor: 2.549

4.  Time-cycled inverse ratio ventilation does not improve gas exchange during anaesthesia.

Authors:  W A Tweed; T L Lee
Journal:  Can J Anaesth       Date:  1991-04       Impact factor: 5.063

5.  Large tidal volume ventilation improves pulmonary gas exchange during lower abdominal surgery in Trendelenburg's position.

Authors:  W A Tweed; W T Phua; K Y Chong; E Lim; T L Lee
Journal:  Can J Anaesth       Date:  1991-11       Impact factor: 5.063

6.  Predictive validity of a novel non-invasive estimation of effective shunt fraction in critically ill patients.

Authors:  Emma M Chang; Andrew Bretherick; Gordon B Drummond; J Kenneth Baillie
Journal:  Intensive Care Med Exp       Date:  2019-08-20

7.  Validation and application of a high-fidelity, computational model of acute respiratory distress syndrome to the examination of the indices of oxygenation at constant lung-state.

Authors:  R A McCahon; M O Columb; R P Mahajan; J G Hardman
Journal:  Br J Anaesth       Date:  2008-06-20       Impact factor: 11.719

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.