Effect of repeated firing on the translucency of CAD-CAM monolithic glass-ceramics.

Farahnaz Nejatidanesh1, Kamran Azadbakht2, Omid Savabi3, Morteza Sharifi4, Mohammadjavad Shirani5.   

Abstract

STATEMENT OF PROBLEM: The effects of multiple firings on the translucency of newly introduced computer-aided design and computer-aided manufacturing (CAD-CAM) glass-ceramics have not been well evaluated.
PURPOSE: The purpose of this in vitro study was to assess the changes in the translucency of high-translucency (HT) and low-translucency (LT) lithium disilicate (LDS) and zirconia-reinforced lithium silicate (ZLS) glass-ceramics of 0.6 and 1 mm thickness during crystallization, correction, and glaze firing cycles.
MATERIAL AND METHODS: Eighty specimens in 8 groups (n=10) were sectioned and polished to obtain thicknesses of 0.6 and 1 mm. The specimens were then fired in 3 cycles, and the color coordinates were measured by using a spectrophotometer after each cycle. The translucency parameter (TP) and the contrast ratio (CR) were calculated to determine the translucency level. The data were analyzed by using a statistical software program. The TP and CR data after each firing cycle were compared within each group by using repeated-measures ANOVA. Pair-wise comparisons were made by using a multiple paired t test. Comparisons between the 2 thicknesses of different materials were made by using the independent t test (α=.05).
RESULTS: Repeated firings significantly increased the translucency of 0.6-mm LT-LDS and decreased the translucency of 0.6-mm HT-ZLS (P<.017). No significant changes were noted in the translucency of specimens of 1-mm thickness after repeated firings. Also, 0.6-mm-thick specimens of all materials had significantly higher translucency than 1-mm-thick specimens (P≤.001). The highest translucency was noted in HT-LDS, followed by HT-ZLS.
CONCLUSIONS: Repeated firings significantly affected the translucency of LDS and ZLS CAD-CAM glass-ceramics. The translucency increased with decreasing thickness.
Copyright © 2019 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2020        PMID: 31916977     DOI: 10.1016/j.prosdent.2019.10.028

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  2 in total

1.  Effect of stain brand and shade on color stability of stains applied on a CAD-CAM feldspathic ceramic.

Authors:  Rafat Sasany; Burak Yilmaz
Journal:  Odontology       Date:  2022-01-18       Impact factor: 2.885

2.  Fracture Resistance of Sintered Monolithic Zirconia Dioxide in Different Thermal Units.

Authors:  Andrea Ordoñez Balladares; Cristian Abad-Coronel; Joao Carlos Ramos; Benjamín José Martín Biedma
Journal:  Materials (Basel)       Date:  2022-03-27       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.