Literature DB >> 31912948

Accuracy of cone beam computed tomography in evaluation of palatal mucosa thickness.

Miho Ogawa1, Sayaka Katagiri1, Tatsuro Koyanagi1, Shogo Maekawa1, Takahiko Shiba1, Yujin Ohsugi1, Yasuo Takeuchi1, Takahiro Ikawa1, Shogo Takeuchi1, Takayuki Sekiuchi1, Yuki Arai2, Ryunosuke Kazama2, Noriyuki Wakabayashi2, Yuichi Izumi1,3, Takanori Iwata1.   

Abstract

AIM: The purpose of this study was to investigate the accuracy of the measurement of palatal mucosa thickness using cone beam computed tomography (CBCT) and to create a conversion formula to evaluate palatal mucosa thickness more accurately. We then evaluated the palatal mucosa thickness in a Japanese population using CBCT and the conversion formula.
MATERIALS AND METHODS: We evaluated palatal mucosa thickness in 10 healthy subjects at 15 sites using CBCT, digital impression, and K file. Multiple regression analysis was performed to create a conversion formula to measure thickness accurately. We then obtained CBCT data from 174 patients retrospectively, applied the conversion formula, and evaluated palatal mucosa thickness.
RESULTS: Sites of measurement affected measurement error. Measurement using CBCT was 0.34 ± 0.04 mm smaller than actual measurement; therefore, a conversion formula was created. Male, age ≥60 years, and probing pocket depth ≥4 mm had significant and positive associations with palatal mucosa thickness; however, no association was observed between bleeding on probing and palatal mucosa thickness.
CONCLUSION: CBCT is useful for the noninvasive and accurate measurement of palatal mucosa thickness.
© 2020 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  CBCT; diagnostic imaging; digital impression; palatal mucosa thickness

Mesh:

Year:  2020        PMID: 31912948     DOI: 10.1111/jcpe.13254

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  3 in total

1.  Digital evaluation of facial peri-implant mucosal thickness and its impact on dental implant aesthetics.

Authors:  Amr Khorshed; Javi Vilarrasa; Alberto Monje; Jose Nart; Gonzalo Blasi
Journal:  Clin Oral Investig       Date:  2022-10-19       Impact factor: 3.606

2.  Measurements of the gingival papillae architecture using cone-beam computed tomography in young Chinese adults.

Authors:  Gang Yang; Jie Cao; Wenjie Hu; Kwok-Hung Chung
Journal:  PeerJ       Date:  2020-09-23       Impact factor: 2.984

3.  Investigation of the palatal soft tissue volume: a 3D virtual analysis for digital workflows and presurgical planning.

Authors:  Anna Seidel; Christian Schmitt; Ragai Edward Matta; Mayte Buchbender; Manfred Wichmann; Lara Berger
Journal:  BMC Oral Health       Date:  2022-08-23       Impact factor: 3.747

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.