Literature DB >> 31912760

Wear and osteolysis outcomes for highly cross-linked polyethylene in primary total hip arthroplasty compared with conventional polyethylene: a 15- to 18-year single-centre follow-up study.

Nam Hoon Moon1, Won Chul Shin2, Min Uk Do2, Suk-Woong Kang2, Sang-Min Lee2, Kuen Tak Suh2.   

Abstract

BACKGROUND: Although highly positive results for wear reduction of highly cross-linked polyethylene (HXLPE) have been reported around the 10-year follow-up, the long-term result related to reoperation and wear-related survival is still an issue. Therefore, this study aimed to compare the follow-up results of a single manufacture's polyethylene liner for >15 years in terms of survival and wear rate.
METHODS: This retrospective cohort study included 134 primary total hip arthroplasties (THAs) who were followed up for at least 15 years. The mean age at the time of surgery was 50.7 years (conventional polyethylene [CPE] group = 22; HXLPE group = 112). Linear and volumetric wear rates of polyethylene were measured, and the reoperation rate and radiographic osteolysis were evaluated and Kaplan-Meier survival analysis was performed in both groups. Implant-related complications were also examined.
RESULTS: HXLPE group showed a significantly lower wear rate in both linear and volumetric wear. None of the hip radiographs showed evidence of loosening or osteolysis in the HXLPE group. The survival rates at 15- to 18-year follow-up were 90.9% and 95.5% in the CPE and HXLPE groups when all-cause reoperation was the endpoint, and 90.9% and 100.0% when the wear-related reoperation was the endpoint, respectively. Implant-related complications were not different between the 2 groups.
CONCLUSIONS: Wear reduction and osteolysis showed a great advantage in HXLPE after a 15-year follow-up. Although the CPE and HXLPE showed excellent survival, wear and osteolysis were more frequent in the CPE; therefore, the high risk of reoperation in the future should be considered.

Entities:  

Keywords:  Conventional polyethylene; highly cross-linked polyethylene; linear and volumetric wear; osteolysis; reoperation rate; total hip arthroplasty

Mesh:

Substances:

Year:  2020        PMID: 31912760     DOI: 10.1177/1120700019896970

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  5 in total

1.  Highly Crosslinked Polyethylene Liners Have Negligible Wear at 10 Years: A Radiostereometric Analysis Study.

Authors:  David G Campbell; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2022-03-01       Impact factor: 4.755

Review 2.  Ultra-high molecular weight polyethylene (UHMWPE) for hip and knee arthroplasty: The present and the future.

Authors:  Alessandro Bistolfi; Fortunato Giustra; Francesco Bosco; Luigi Sabatini; Alessandro Aprato; Pierangiola Bracco; Anuj Bellare
Journal:  J Orthop       Date:  2021-04-23

3.  Total Hip Arthroplasty With Subtrochanteric Osteotomy for Developmental Hip Dysplasia: A Long-term Follow-up Study.

Authors:  Brian T Palumbo; Kevin Salomon; Alex Sullivan; Peter Simon; Steven Lyons; Thomas L Bernasek
Journal:  Arthroplast Today       Date:  2022-08-22

4.  Recent update on crosslinked polyethylene in total hip arthroplasty.

Authors:  Jean Langlois; Moussa Hamadouche
Journal:  SICOT J       Date:  2020-05-15

5.  The use of acetabular screws in total hip arthroplasty and its influence on wear and periacetabular osteolysis in the long-term follow-up.

Authors:  Steffen Brodt; Kathleen Bischoff; Marcel Schulze; Dimitri Nowack; Andreas Roth; Georg Matziolis
Journal:  Int Orthop       Date:  2021-09-28       Impact factor: 3.075

  5 in total