Literature DB >> 31912523

Clinical and radiographic changes at tissue level implants with either a machined or a modified transmucosal neck surface: A 3-year multicentre randomized controlled proof-of-concept study.

Giovanni E Salvi1, Raphaël Moëne2, Beat Wallkamm1,3, Stefan P Hicklin4, Mark Bischof5, Rabah Nedir5, Andrea Mombelli2, Anton Sculean1.   

Abstract

BACKGROUND: Surface modification may yield enhanced soft tissue adhesion to transmucosal titanium implant necks. AIM: To evaluate and compare changes in soft tissues around implants with a modified hydrophilic sandblasted and acid-etched neck (mSLA; test) to those with a machined neck (M; control).
MATERIALS AND METHODS: Implants with a diameter of 4.1 mm and a neck height of 1.8 mm were randomly inserted in healed sites with pristine bone of the posterior maxilla or mandible. The modified Sulcus Bleeding Index (mSBI) (primary outcome) was assessed at baseline (BL) and 6, 12 and 36 months. Secondary outcomes included the assessment of pocket probing depth (PPD), mucosal recession (REC) and clinical attachment level (CAL). Standardized radiographs were taken at time of implant placement, at BL and after 12 and 36 months.
RESULTS: Of the 43 randomized subjects, 38 (19 test and 19 controls) completed the 36-month follow-up. Implant survival rates amounted to 95.5% (test) and 100% (control) (p > .05). At 36 months, 77.6% of test implants and 78.9% of control implants were without any bleeding sites (mSBI = 0; p > .05). The 36-month success rate was 86.4% in the test and 85.7% in the control group, respectively (p > .05). At 36 months, the mean radiographic bone level change from BL was 0.33 ± 0.69 mm at test implants and 0.12 ± 0.3 mm at control implants (p > .05).
CONCLUSION: Tissue level implants with a hydrophilic mSLA transmucosal neck failed to yield clinical and radiographic benefits compared with implants with a machined neck up to 3 years.
© 2020 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  dental implant; implant surface modification; soft tissue integration; titanium; transmucosal

Mesh:

Substances:

Year:  2020        PMID: 31912523     DOI: 10.1111/jcpe.13249

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  2 in total

1.  The Mechanical Behavior of a Screwless Morse Taper Implant-Abutment Connection: An In Vitro Study.

Authors:  Aimen Bagegni; Vincent Weihrauch; Kirstin Vach; Ralf Kohal
Journal:  Materials (Basel)       Date:  2022-05-08       Impact factor: 3.748

2.  Influence of Periodontitis, Implant, and Prosthesis Characteristics on the Peri-Implant Status: A Cross-Sectional Study.

Authors:  Ioanna Papalou; Panagiota Vagia; Ahmet Cakir; Henri Tenenbaum; Olivier Huck; Jean-Luc Davideau
Journal:  Int J Dent       Date:  2022-02-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.