Literature DB >> 319107

Reduction of variation in results of rheumatoid factor tests by use of a serum reference preparation.

R N Taylor, K M Fulford, W L Jones.   

Abstract

Standaridizing test results for rheumatoid factor by comparing results obtained for an unknown with results obtained for a serum reference preparation decreased variance between laboratories, as measured in the Center for Disease Control proficiency testing program, by 77%. The amount of improvement was also estimated by the type of test and by the manufacturer's product. Standardization resulted in an increase in the number of reported results that were within a twofold dilution of the median value. The percentage increased from 50.3 to 93.7% for the slide tests and from 78.1 to 91.2% fro the tube tests. Decrease in variance by manufacturer's product ranged from 94 to 27%. The study demonstrated that adopting a reference serum standard could substantially improve the comparability of rheumatoid factor test results and that proficiency testing programs can be used to estimate improvement which could be expected as a result of standardization.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 319107      PMCID: PMC274529          DOI: 10.1128/jcm.5.1.42-45.1977

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  3 in total

1.  A study of rheumatoid arthritis latex kits.

Authors:  W L Jones; G L Wiggins
Journal:  Am J Clin Pathol       Date:  1973-11       Impact factor: 2.493

2.  Evaluation of tests for infectious mononucleosis through proficiency testing.

Authors:  R N Taylor; H B Ehrhard; S Marcus
Journal:  Health Lab Sci       Date:  1976-01

3.  International reference preparation of rheumatoid arthritis serum.

Authors:  S G Anderson; M W Bentzon; V Houba; P Krag
Journal:  Bull World Health Organ       Date:  1970       Impact factor: 9.408

  3 in total
  6 in total

1.  Center for Disease Control Diagnostic Immunology Proficiency Testing Program results for 1977.

Authors:  R N Taylor; K M Fulford; V A Przybyszewski; V Pope
Journal:  J Clin Microbiol       Date:  1978-10       Impact factor: 5.948

2.  Center for disease control diagnostic immunology proficiency testing program results for 1976.

Authors:  R N Taylor; K M Fulford; A Przybyszewski; V Pope
Journal:  J Clin Microbiol       Date:  1977-09       Impact factor: 5.948

3.  Center for Disease Control Diagnostic Immunology Proficiency Testing Program results for 1978.

Authors:  R N Taylor; K M Fulford; V A Przybyszewski; V Pope
Journal:  J Clin Microbiol       Date:  1979-12       Impact factor: 5.948

4.  Assessment of laboratory improvement by the Center for Disease Control Diagnostic Immunology Proficiency Testing Program.

Authors:  R N Taylor; K M Fulford
Journal:  J Clin Microbiol       Date:  1981-02       Impact factor: 5.948

5.  Evaluation of a charcoal particle test for rheumatoid factor.

Authors:  R W Stevens; K E Hechemy; J H Miller
Journal:  J Clin Microbiol       Date:  1981-05       Impact factor: 5.948

6.  Reference preparation to standardize results of serological tests for rheumatoid factor.

Authors:  K M Fulford; R N Taylor; V A Przybyszewski
Journal:  J Clin Microbiol       Date:  1978-05       Impact factor: 5.948

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.