Literature DB >> 31903978

The effect of diameter, length and elastic modulus of a dental implant on stress and strain levels in peri-implant bone: A 3D finite element analysis.

Amanda Robau-Porrua1, Yoan Pérez-Rodríguez2, Laura M Soris-Rodríguez1, Osmel Pérez-Acosta2, Jesús E González3.   

Abstract

This study investigated the effect of three different parameters of a dental implant on stress and strain values in the peri-implant bone by finite element analysis. In this work, the effect of diameter, length and elastic modulus on the biomechanical behavior of a new dental implant was simulated using the finite element method. A three-dimensional model of a mandible segment corresponding to the premolar region and twelve dental implant models were obtained. Loads in three directions were distributed on the surface of the coronal area of the dental implants. The dental implant models were obtained in the FreeCAD 0.16 software and the simulations were made using the Abaqus/CAE software. In all cases, higher stress concentrations were obtained in the peri-implant cortical bone between 40.6 and 62.8 MPa, while the highest levels of strain were observed in the peri-implant trabecular bone between 0.002544 and 0.003873. In general, the highest von Mises equivalent stress values were observed in the peri-implant cortical bone. However, in this bone, both the maximum von Mises equivalent stress values and the von Mises strain are similar or inferior to those reported in different studies by finite element for other models of dental implants under immediate loading. Maximum von Mises strain values were observed in peri-implant trabecular bone. However, in this bone strains levels were obtained that maintain bone density or increase it. The effect of the three simulated variables (implant diameter, length, and elastic modulus) have a statistically significant influence on the von Mises equivalent stress and in von Mises strain values.

Entities:  

Keywords:  Dental implant; elastic modulus; finite element method; strain; stress

Mesh:

Substances:

Year:  2020        PMID: 31903978     DOI: 10.3233/BME-191073

Source DB:  PubMed          Journal:  Biomed Mater Eng        ISSN: 0959-2989            Impact factor:   1.300


  3 in total

1.  In Vivo and In Vitro Analyses of Titanium-Hydroxyapatite Functionally Graded Material for Dental Implants.

Authors:  Xinhua Wang; Chengpeng Wan; Xiaoxia Feng; Fuyan Zhao; Huiming Wang
Journal:  Biomed Res Int       Date:  2021-04-30       Impact factor: 3.411

2.  Comparison of stresses in monoblock tilted implants and conventional angled multiunit abutment-implant connection systems in the all-on-four procedure.

Authors:  Özge Özdal Zincir; Ateş Parlar
Journal:  BMC Oral Health       Date:  2021-12-16       Impact factor: 2.757

Review 3.  Bioengineering Tools Applied to Dentistry: Validation Methods for In Vitro and In Silico Analysis.

Authors:  Jefferson David Melo de Matos; Daher Antonio Queiroz; Leonardo Jiro Nomura Nakano; Valdir Cabral Andrade; Nathália de Carvalho Ramos Ribeiro; Alexandre Luiz Souto Borges; Marco Antonio Bottino; Guilherme da Rocha Scalzer Lopes
Journal:  Dent J (Basel)       Date:  2022-08-04
  3 in total