Literature DB >> 31901838

Clinical radiotherapy application of N-vinylpyrrolidone-containing 3D polymer gel dosimeters with remote external MR-reading.

Marek Kozicki1, Andreas Berg2, Piotr Maras3, Malwina Jaszczak4, Mariusz Dudek5.   

Abstract

PURPOSE: Advanced 3D dosimetry is required for verifications of complex dose distributions in modern radiotherapy. Two 3D polymer gel dosimeters, coupled with magnetic resonance (MR) imaging (3 T MRI) readout and data processing with polyGeVero® software, were tested for the verification of calculated 3D dose distributions by a treatment planning system (TPS) and ArcCHECK®-3DVH®, related to eradication of a lung tumour.
METHODS: N-vinylpyrrolidone-containing 3D polymer gel dosimeters were used: VIC (containing ascorbic acid and copper sulfate pentahydrate) and VIC-T (containing tetrakis(hydroxymethyl)phosphonium chloride). Three remote centers were involved in the dosimeters preparation and irradiation (Poland), and MRI (Austria). Cross beam calibration of the dosimeters and verification of a 3D dose distribution calculated with an Eclipse External Beam TPS and ArcCHECK®-3DVH® were performed. The 3D-to-3D comparisons of the VIC and VIC-T with TPS and ArcCHECK®-3DVH® along with ArcCHECK®-3DVH® versus TPS dose matrixes were performed with the aid of the polyGeVero® by analyzing dose profiles, isodoses lines, gamma index, gamma angle, dose difference, and related histograms.
RESULTS: The measured MR-relaxation rate (R2 = 1/T2) for the dosimeters relates to the dose, as follows: R2 = 0.0928 ± 0.0008 [Gy-1 s-1] × D [Gy] + 2.985 ± 0.012 [s-1] (VIC) and 0.1839 ± 0.0044 [Gy-1 s-1] × D [Gy] + 2.519 ± 0.053 [s-1] (VIC-T). The 3D-to-3D comparisons revealed a good agreement between the measured and calculated 3D dose distributions.
CONCLUSIONS: VIC and VIC-T with 3T MRI readout and polyGeVero® showed potential for verifications of calculated irradiation plans. The results obtained suggest the implementation of the irradiation plan for eradication of the lung tumour.
Copyright © 2019 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  3D radiotherapy dosimetry; 3T MRI; ArcCHECK–3DVH verification; TPS verification; VIC; VIC-T; polyGeVero software

Mesh:

Substances:

Year:  2020        PMID: 31901838     DOI: 10.1016/j.ejmp.2019.11.014

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  4 in total

1.  Improved Dose Response of N-(hydroxymethyl)acrylamide Gel Dosimeter with Calcium Chloride for Radiotherapy.

Authors:  Khalid A Rabaeh; Rawan E Al-Tarawneh; Molham M Eyadeh; Issra' M E Hammoudeh; Moneeb T M Shatnawi
Journal:  Gels       Date:  2022-01-26

2.  Features of PABIGnx 3D Polymer Gel as an Ionising Radiation Dosimeter.

Authors:  Marek Kozicki; Malwina Jaszczak; Piotr Maras
Journal:  Materials (Basel)       Date:  2022-03-31       Impact factor: 3.623

Review 3.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

4.  Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy.

Authors:  Piotr Maras; Marek Kozicki
Journal:  Materials (Basel)       Date:  2022-09-30       Impact factor: 3.748

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.