Literature DB >> 31900969

Accuracy of dynamic preload variables for predicting fluid responsiveness in patients with pediatric liver cirrhosis: A prospective study.

Pin-Hsin Chen1, Kuang-Cheng Chan1, Min-Hsiu Liao1, Chun-Yu Wu1.   

Abstract

BACKGROUND: We have previously reported that dynamic preload variables predicted fluid responsiveness in adult patients with liver cirrhosis. However, pediatric patients with cirrhosis may present with unique hemodynamic characteristics, and therefore, the predictive accuracy of these variables in such patients must be clarified. AIMS: To investigate the accuracy of dynamic preload variables for predicting fluid responsiveness in pediatric patients with cirrhosis.
METHODS: A total of 27 pediatric patients with cirrhosis undergoing orthotopic liver transplantation were enrolled in this study. Patients' pulse pressure variation, stroke volume variation, stroke volume index, and central venous pressure were measured using the calibrated pulse contour cardiac output system. The plethysmographic variability index was measured using a Masimo Radical 7 co-oximeter. During the hepatic dissection phase of the surgery, repeated intraoperative fluid challenges with 10 mL kg-1 of crystalloid within 15 minutes were administered. Fluid responsiveness was defined as an increase in stroke volume index of ≥15% after fluid challenge.
RESULTS: A total of 61 fluid challenges were administered resulting in 15 fluid responders and 46 fluid nonresponders. Fluid challenge induced significant decreases in all three dynamic preload variables but not in the fluid nonresponders. However, the area under the receiver operating characteristic curves for pulse pressure variation, stroke volume variation, plethysmographic variability index, and central venous pressure for predicting fluid responsiveness were 0.67 (95% confidence interval: 0.52-0.82; P = .0255), 0.68 (95% confidence interval: 0.54-0.83; P = .0140), 0.56 (95% confidence interval: 0.40-0.71; P = .4724), and 0.57 (95% confidence interval: 0.40-0.74; P = .4192), respectively.
CONCLUSIONS: Dynamic preload variables do not predict fluid responsiveness in pediatric patients with liver cirrhosis.
© 2020 John Wiley & Sons Ltd.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 31900969     DOI: 10.1111/pan.13819

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.556


  2 in total

1.  [Comparison of pulse pressure variation, stroke volume variation, and plethysmographic variability index in pediatric patients undergoing craniotomy].

Authors:  Y F Liu; L L Song; M W Xing; L X Cai; D X Wang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2021-10-18

2.  Dynamic variables predict fluid responsiveness in pre-school and school children undergoing neurosurgery: a prospective observational study.

Authors:  Lin-Lin Song; Zhi-Yu Geng; Wei Ma; Ya-Fei Liu; Dong-Xin Wang
Journal:  Transl Pediatr       Date:  2021-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.