| Literature DB >> 31900130 |
Halley P Crissman1, Charisse Loder2,3, Carlo Pancaro4, Jason Bell2,3.
Abstract
BACKGROUND: Amniotic fluid embolism (AFE) is a rare, life threatening obstetric complication, often associated with severe coagulopathy. Induced abortions are extremely safe procedures however complications including AFE can occur. CASEEntities:
Keywords: Abortion; Amniotic fluid embolism; Case report; Coagulopathy; Thromboelastography; Viscoelastic point-of-care analysis
Mesh:
Year: 2020 PMID: 31900130 PMCID: PMC6942409 DOI: 10.1186/s12884-019-2680-1
Source DB: PubMed Journal: BMC Pregnancy Childbirth ISSN: 1471-2393 Impact factor: 3.007
Timeline of laboratory results, ROTEM® results, and interventions in order of time when intervention or testing was initiated
| Event or Intervention | Time Obtained | Processing Timea (minutes) | CBCb | aPTT (seconds) | INR | Fibrinogen (milligrams/deciliter)/FIBTEM A10 (mm) | EXTEM Clotting Time (CT) and A10 |
|---|---|---|---|---|---|---|---|
| Pre-Op | 12.1 134 | ||||||
| Event | Dilation and evacuation completed at 08:34. | ||||||
| Event | Ongoing vaginal bleeding, episode of hypotension, return to the OR at 10:28. | ||||||
| Lab 1 | 10:51 | 88 | 10.4 84 | 38.0 | 1.7 | ||
| Lab 2 | 13:08 | 132 | 10.6 93 | 38.5 | 2.0 | Fibrinogen < 25 | |
| ROTEM® 1 | 13:30 | Undetectable FIBTEM value | CT = 359 s, A10 = 16 mm | ||||
| Intervention | At time of ROTEM® 1 result, initiated 3 g concentrated fibrinogen, 1 unit FFP, 1 × 5-pack platelets. | ||||||
| Lab 3 | 14:21 | 72 | 9.5 53 | 34.4 | 1.4 | Fibrinogen 49 | |
| ROTEM® 2 | 14:21 | 2 mm FIBTEM (low amplitude) | Improvement in EXTEM. CT = 187 s, A10 = 20 mm | ||||
| Intervention | At time of ROTEM® 2 result, initiated 1 g concentrated fibrinogen, 2 units of cryoprecipitate, 3 units of FFP, 1 × 5-pack platelets, 2 g TXA. | ||||||
| Lab 4 | 15:47 | 57 | 6.2 81 | 22.4 | 1.0 | Fibrinogen 255 | |
| Intervention | 1 unit cryoprecipitate, 2 units red blood cells given between obtaining Lab 4 and receiving the results. | ||||||
| ROTEM® 3 | 16:44 | 13 mm FIBTEM (normal amplitude) | Normal EXTEM. CT = 60 s, A10 = 45 mm | ||||
| Lab 5 | 17:01 | 53 | 8.7 79 | 26.6 | 1.0 | Fibrinogen 243 | |
| Intervention | 2 × 5-pack platelets. | ||||||
| 22:21 | 34 | 8.8 141 | 25.3 | 1.0 | Fibrinogen 283 | ||
aProcessing time (minutes) reflects the time from lab collection to the full panel of labs resulting in the electronic medical record system
b Hgb Platelets
Complete blood count (CBC) with hemoglobin (Hgb) measured in grams/deciliter, platelets in unit × 103/μl. Activated partial thromboplastin time (aPTT), International Normalized Ratio (INR), clot amplitude at 10 min (A10), clotting time (CT), rotational thromboelastography (ROTEM®), fresh frozen plasma (FFP), tranexamic acid (TXA)
Fig. 1ROTEM® 1: ROTEM® results show very low amplitude fibrinogen; FIBTEM A10 is undetectable. EXTEM results show prolonged CT (359 s) and low clot A10 in the EXTEM (16 mm)
Fig. 2ROTEM® 2: ROTEM® results continue to show severe hypofibrinogemia; FIBTEM A10 value of 2 mm. EXTEM results suggest some improvement in CT (187 s) and A10 (20 mm)
Fig. 3ROTEM® 3: ROTEM® show normalization of fibrinogen levels; FIBTEM A10 of 13 mm. EXTEM results show normalization of CT (60 s), and A10 (45 mm)