Pulse oximetry based on photoplethysmography imaging with red and green light : Calibratability and challenges.

Andreia Moço1, Wim Verkruysse2.   

Abstract

Remotely measuring the arterial blood oxygen saturation (SpO2) in visible light (Vis) involves different probing depths, which may compromise calibratibility. This paper assesses the feasibility of calibrating camera-based SpO2 (SpO2,cam) using red and green light. Camera-based photoplethysmographic (PPG) signals were measured at 46 healthy adults at center wavelengths of 580 nm (green), 675 nm (red), and 840 nm (near-infrared; NIR). Subjects had their faces recorded during normoxia and hypoxia and under gradual cooling. SpO2,cam estimates in Vis were based on the normalized ratio of camera-based PPG amplitudes in red over green light (RoG). SpO2,cam in Vis was validated against contact SpO2 (reference) and compared with SpO2,cam estimated using red-NIR wavelengths. An RoG-based calibration curve for SpO2 was determined based on data with a SpO2 range of 85-100%. We found an [Formula: see text] error of 2.9% (higher than the [Formula: see text] for SpO2,cam in red-NIR). Additional measurements on normoxic subjects under temperature cooling (from [Formula: see text] to [Formula: see text]) evidenced a significant bias of - 1.7, CI [- 2.7, - 0.7]%. It was also noted that SpO[Formula: see text] estimated at the cheeks was significantly biased (- 3.6, CI [- 5.7, - 1.5]%) with respect to forehead estimations. Under controlled conditions, SpO[Formula: see text] can be calibrated with red and green light but the accuracy is less than that of SpO[Formula: see text] estimated in the usual red-NIR window.

Entities:  

Keywords:  Calibration; PPG imaging; Pulse oximetry; Video-health monitoring

Year:  2020        PMID: 31893325     DOI: 10.1007/s10877-019-00449-y

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  4 in total

Review 1.  An Overview of the Sensors for Heart Rate Monitoring Used in Extramural Applications.

Authors:  Alessandra Galli; Roel J H Montree; Shuhao Que; Elisabetta Peri; Rik Vullings
Journal:  Sensors (Basel)       Date:  2022-05-26       Impact factor: 3.847

Review 2.  Skin Pigmentation Influence on Pulse Oximetry Accuracy: A Systematic Review and Bibliometric Analysis.

Authors:  Ana M Cabanas; Macarena Fuentes-Guajardo; Katina Latorre; Dayneri León; Pilar Martín-Escudero
Journal:  Sensors (Basel)       Date:  2022-04-29       Impact factor: 3.847

Review 3.  A review of wearable and unobtrusive sensing technologies for chronic disease management.

Authors:  Yao Guo; Xiangyu Liu; Shun Peng; Xinyu Jiang; Ke Xu; Chen Chen; Zeyu Wang; Chenyun Dai; Wei Chen
Journal:  Comput Biol Med       Date:  2020-12-13       Impact factor: 4.589

4.  Innovative measurement of routine physiological variables (heart rate, respiratory rate and oxygen saturation) using a remote photoplethysmography imaging system: a prospective comparative trial protocol.

Authors:  Edem Allado; Mathias Poussel; Anthony Moussu; Véronique Saunier; Yohann Bernard; Eliane Albuisson; Bruno Chenuel
Journal:  BMJ Open       Date:  2021-08-13       Impact factor: 2.692

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.