Literature DB >> 31888362

Polyethylene manufacturing characteristics have a major effect on the risk of revision surgery in cementless and hybrid total hip arthroplasties.

Edward T Davis1,2, Joseph Pagkalos1, Branko Kopjar3,4.   

Abstract

AIMS: The aim of this study was to identify the effect of the manufacturing characteristics of polyethylene acetabular liners on the survival of cementless and hybrid total hip arthroplasty (THA).
METHODS: Prospective cohort study using linked National Joint Registry (NJR) and manufacturer data. The primary endpoint was revision for aseptic loosening. Cox proportional hazard regression was the primary analytical approach. Manufacturing variables included resin type, crosslinking radiation dose, terminal sterilization method, terminal sterilization radiation dose, stabilization treatment, total radiation dose, packaging, and face asymmetry. Total radiation dose was further divided into G1 (no radiation), G2 (> 0 Mrad to < 5 Mrad), G3 (≥ 5 Mrad to < 10 Mrad), and G4 (≥ 10 Mrad).
RESULTS: A total of 5,329 THAs were revised, 1,290 of which were due to aseptic loosening. Total radiation dose, face asymmetry, and stabilization treatments were found to significantly affect implant survival. G1 had the highest revision risk for any reason and for aseptic loosening and G3 and G4 the lowest. Compared with G1, the adjusted hazard ratio for G2 was 0.74 (95% confidence interval (CI) 0.64 to 0.86), G3 was 0.36 (95% CI 0.30 to 0.43), and G4 was 0.38 (95% CI 0.31 to 0.47). The cumulative incidence of revision for aseptic loosening at 12 years was 0.52 and 0.54 per 100 THAs for G3 and G4, respectively, compared with 1.95 per 100 THAs in G1. Asymmetrical liners had a lower revision risk due to aseptic loosening and reasons other than aseptic loosening compared with symmetric (flat) liners. In G3 and G4, stabilization with vitamin E and heating above melting point performed best.
CONCLUSION: Polyethylene liners with a total radiation dose of ≥ 5 Mrad, an asymmetrical liner face, and stabilization with heating above the melting point demonstrate best survival. Cite this article: Bone Joint J 2020;102-B(1):90-101.

Entities:  

Keywords:  Acetabular liner; Arthroplasty; Cementation; Conventional polyethylene; Modified polyethylene; Polyethylene; Prosthesis design; Revision

Mesh:

Substances:

Year:  2020        PMID: 31888362     DOI: 10.1302/0301-620X.102B1.BJJ-2019-0779.R1

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  7 in total

1.  Highly Crosslinked Polyethylene Liners Have Negligible Wear at 10 Years: A Radiostereometric Analysis Study.

Authors:  David G Campbell; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2022-03-01       Impact factor: 4.755

2.  Effect of Bearing Surface on Survival of Cementless and Hybrid Total Hip Arthroplasty: Study of Data in the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man.

Authors:  Edward T Davis; Joseph Pagkalos; Branko Kopjar
Journal:  JB JS Open Access       Date:  2020-05-15

3.  A higher degree of polyethylene irradiation is associated with a reduced risk of revision for aseptic loosening in total hip arthroplasties using cemented acetabular components: an analysis of 290,770 cases from the National Joint Registry of England, Wales, Northern Island and the Isle of Man.

Authors:  Edward T Davis; Joseph Pagkalos; Branko Kopjar
Journal:  Bone Joint Res       Date:  2020-09-20       Impact factor: 5.853

4.  Implant survival of 2,723 vitamin E-infused highly crosslinked polyethylene liners in total hip arthroplasty: data from the Finnish Arthroplasty Register.

Authors:  Matias Hemmilä; Inari Laaksonen; Markus Matilainen; Antti Eskelinen; Jaason Haapakoski; Ari-Pekka Puhto; Jukka Kettunen; Konsta Pamilo; Keijo T Mäkelä
Journal:  Acta Orthop       Date:  2021-02-01       Impact factor: 3.717

5.  Long-term survival of hybrid total hip replacement for prior failed proximal femoral nail antirotation: a retrospective study with a median 10-year follow-up.

Authors:  Lin Wang; Minji Yu; Yaodong Zhang; Shuxin Wang; Mingdong Zhao; Mingliang Yu; Si Li; Songtao Gao; Min Xiong; Weiguang Yu
Journal:  BMC Musculoskelet Disord       Date:  2022-09-16       Impact factor: 2.562

6.  Long-term survival after cemented versus uncemented total hip arthroplasty for treatment of acute femoral neck fracture: a retrospective study with a mean 10-year follow-up.

Authors:  Chi Zhang; Meiji Chen; Weiguang Yu; Xiulan Han; Junxing Ye; Jintao Zhuang
Journal:  J Int Med Res       Date:  2020-09       Impact factor: 1.671

7.  Recent update on crosslinked polyethylene in total hip arthroplasty.

Authors:  Jean Langlois; Moussa Hamadouche
Journal:  SICOT J       Date:  2020-05-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.