| Literature DB >> 31881971 |
Hanan Mostafa1, Mohamed Shaban1, Ahmed Hasanin2,3, Hassan Mohamed1, Shymaa Fathy1, Hossam M Abdelreheem1, Ahmed Lotfy1, Ayman Abougabal1, Ahmed Mukhtar1, Akram El-Adawy1.
Abstract
BACKGROUND: Intradialytic hypotension is a serious complication during renal replacement therapy in critically ill patients. Early prediction of intradialytic hypotension could allow adequate prophylactic measures. In this study we evaluated the ability of peripheral perfusion index (PPI) and heart rate variability (HRV) to predict intradialytic hypotension.Entities:
Keywords: Heart rate variability; Intradialytic hypotension; Peripheral perfusion index
Mesh:
Year: 2019 PMID: 31881971 PMCID: PMC6935124 DOI: 10.1186/s12871-019-0917-1
Source DB: PubMed Journal: BMC Anesthesiol ISSN: 1471-2253 Impact factor: 2.217
Demographic data and patient characteristics. Data are presented as mean ± standard deviation, median (quartiles), and frequency (%)
| Hypotensive group | Stable Group | ||
|---|---|---|---|
| Age (years) | 49 ± 13 | 55 ± 9 | 0.15 |
| Male gender | 20 (87%) | 8 (62%) | 0.1 |
| APACHE II | 26 ± 6 | 21 ± 6 | 0.02 |
| Diabetes | 12(52%) | 10(77%) | 0.18 |
| Chronic hypertension | 16(70%) | 10(77%) | 0.72 |
| Ischemic heart disease | 3(13%) | 3(23%) | 0.4 |
| Chronic liver disease | 2(9%) | 3(23%) | 0.3 |
| Pulmonary edema | 1(4%) | 5(39%) | 0.02 |
| Fluid removed during session | 1615 ± 650 | 1543 ± 562 | 0.73 |
| Baseline SBP (mmHg) | 120(113,127) | 148(122,155) | 0.001 |
| Baseline heart rate (bpm) | 96 ± 18 | 92 ± 15 | 0.51 |
| Baseline CVP (cmH2O) | 16 ± 6 | 15 ± 5 | 0.55 |
| Baseline cardiac output (L/minute) | 9.3 ± 3 | 9.7 ± 2.4 | 0.67 |
| Baseline systemic vascular resistance ( | 806(686,1252) | 729(631,980) | 0.149 |
APACHE Acute physiology and chronic health evaluation, CVP central venous pressure, SBP systolic blood pressure
Predictive properties for perfusion index and electrical cardiometry measures for hypotension
| AUROC | 95% CI | Sensitivity | Specificity | PPV | NPV | Cut-off value | |
|---|---|---|---|---|---|---|---|
| PPI | 0.721 | 0.547–0.857 | 100% | 56% | 80% | 100% | ≤1.8 |
| HRV | 0.761 | 0.59–0.887 | 61% | 91% | 92% | 56% | ≤24 |
HRV heart rate variability, PPI peripheral perfusion index
Fig. 1Receiver operating characteristic curves for different variables to detect intradialytic hypotension. HRV: heart rate variability, PPI: peripheral perfusion index