Physicochemical changes and protein denaturation were evaluated for pork longissimus dorsi muscle subjected to different thawing methods. Fresh pork longissimus dorsi muscle served as a control. Microwave (MT), microwave combined with ultrasonic (MUT), microwave combined with 35 °C water immersion (MIT), microwave combined with 4 °C refrigeration (MRT), microwave combined with air convection (MAT), and microwave combined with running water (MWT) were applied. All microwave-based methods excepted for MT avoided localized overheating. The changes in the water holding capacity (WHC), color, TBARS, and protein solubility were lowest with MAT. Differential scanning calorimetry (DSC) and dynamic rheological property measurements indicated, that the MAT samples changed only slightly and presented with complete peaks and high G' values compared with the other treatments. Thus, MAT may reduce protein denaturation associated with meat thawing. The results of this study indicated that MAT effectively shortens thawing time, preserves meat quality and uniformity, and could benefit the meat industry and those who consume its products.Entities:
Keywords: differential scanning calorimetry; dynamic rheological property; physicochemical properties; pork longissimus dorsi muscle; thawing
Year: 2019 PMID: 31881759 PMCID: PMC7023265 DOI: 10.3390/foods9010026
Source DB: PubMed Journal: Foods ISSN: 2304-8158
Figure 1Localized overheating in pork samples thawed by microwave. Core temperatures were −4 °C, −3 °C, −2 °C, and −1 °C.
Figure 2Temperature changes in frozen pork samples under six different thawing conditions. MT: Microwave thawing (100 W); MUT: Microwave combined with ultrasonic thawing; MIT: Microwave combined with 35 °C water immersion thawing; MRT: Microwave combined with 4 °C refrigeration thawing; MAT: Microwave combined with air convection thawing; MWT: Microwave combined with running water thawing.
Changes in water holding capacity of pork samples under six different thawing conditions.
| Parameter | Thawing Ways | ||||||
|---|---|---|---|---|---|---|---|
| Control | MT | MUT | MIT | MRT | MAT | MWT | |
| Thawing loss (%) | - | 2.26 ± 0.15 c | 3.05 ± 0.27 b | 3.27 ± 0.20 b | 5.34 ± 0.09 a | 2.50 ± 0.19 c | 1.74 ± 0.12 d |
| Centrifugation loss (%) | 20.69 ± 0.44 c | 23.09 ± 0.22 a | 23.31 ± 0.37 a | 23.59 ± 1.11 a | 21.93 ± 0.49 b | 20.84 ± 0.16 c | 21.93 ± 0.35 b |
| Cooking loss (%) | 21.77 ± 0.20 de | 22.46 ± 0.54 bcd | 22.36 ± 0.73 cd | 22.82 ± 0.19 abc | 23.38 ± 0.66 ab | 21.23 ± 0.39 e | 23.48 ± 0.59 a |
| Drip loss (%) | 4.50 ± 0.16 d | 6.53 ± 0.11 a | 5.96 ± 0.40 bc | 5.66 ± 0.28 c | 6.32 ± 0.38 ab | 4.76 ± 0.11 d | 5.68 ± 0.17 c |
| Total loss (%) | - | 54.35 ± 0.85 b | 54.68 ± 0.69 b | 55.35 ± 0.84 b | 56.97 ± 0.97 a | 49.34 ± 0.71 d | 52.80 ± 0.96 c |
| Shear force (N) | 31.08 ± 0.96 bc | 28.77 ± 1.01 de | 29.43 ± 1.20 cd | 27.56 ± 0.98 de | 27.34 ± 0.83 e | 31.71 ± 1.34 b | 35.98 ± 1.00 a |
MT: Microwave thawing (100 W); MUT: Microwave combined with ultrasonic thawing; MIT: Microwave combined with 35 °C water immersion thawing; MRT: Microwave combined with 4 °C refrigeration thawing; MAT: Microwave combined with air convection thawing; MWT: Microwave combined with running water thawing. Data are means ± SE. a–d values in the same row followed by different letters are significantly different according to Duncan’s multiple range test (p < 0.05).
Changes in color and thiobarbituric acid-reactive substances (TBARS) values of pork samples under six different thawing conditions.
| Parameter | Thawing Ways | ||||||
|---|---|---|---|---|---|---|---|
| Control | MT | MUT | MIT | MRT | MAT | MWT | |
| L* | 50.18 ± 1.99 ab | 51.94 ± 2.22 a | 48.56 ± 0.68 bc | 52.70 ± 0.82 a | 47.01 ± 0.19 c | 51.22 ± 1.97 ab | 52.92 ± 1.07 a |
| a* | 6.27 ± 0.09 a | 5.99 ± 0.01 b | 5.78 ± 0.21 bc | 5.98 ± 0.14 b | 5.57 ± 0.17 c | 6.21 ± 0.03 a | 5.56 ± 0.08 c |
| b* | 4.82 ± 0.36 ab | 5.24 ± 0. 29 a | 4.65 ± 0.05 b | 5.11 ± 0.29 ab | 4.74 ± 0.18 b | 4.93 ± 0.23 ab | 4.90 ± 0.18 ab |
| ∆E | - | 1.92 ± 0.12 c | 2.09 ± 0.24 c | 2.64 ± 0.37 bc | 3.41 ± 0.23 a | 1.18 ± 0.39 d | 2.90 ± 0.77 ab |
| 0.16 ± 0.01 d | 0.17 ± 0.01 cd | 0.26 ± 0.02 c | 0.23 ± 0.01 b | 0.18 ± 0.01 c | 0.16 ± 0.01 d | 0.27 ± 0.02 a | |
MT: Microwave thawing (100 W); MUT: Microwave combined with ultrasonic thawing; MIT: Microwave combined with 35 °C water immersion thawing; MRT: Microwave combined with 4 °C refrigeration thawing; MAT: Microwave combined with air convection thawing; MWT: Microwave combined with running water thawing. Data are means ± SE. a–d values in the same row followed by different letters are significantly different according to Duncan’s multiple range test (p < 0.05).
Figure 3Changes in pH (a), total volatile base nitrogen (TVB-N, (b)), electrical conductivity, (c) and total viable counts (d) of pork samples under six different thawing conditions. MT: Microwave thawing (100 W); MUT: Microwave combined with ultrasonic thawing; MIT: Microwave combined with 35 °C water immersion thawing; MRT: Microwave combined with 4 °C refrigeration thawing; MAT: Microwave combined with air convection thawing; MWT: Microwave combined with running water thawing. a–d values in the same series followed by different letters are significantly different according to Duncan’s multiple range test (p < 0.05).
Figure 4Changes in pork protein solubility under six different thawing conditions. MT: Microwave thawing (100 W); MUT: Microwave combined with ultrasonic thawing; MIT: Microwave combined with 35 °C water immersion thawing; MRT: Microwave combined with 4 °C refrigeration thawing; MAT: Microwave combined with air convection thawing; MWT: Microwave combined with running water thawing. a–d values in the same series followed by different letters are significantly different according to Duncan’s multiple range test (p < 0.05).
Figure 5Typical differential scanning calorimetry (DSC) scans of the muscle proteins in pork under six different thawing conditions. MT: Microwave thawing (100 W); MUT: Microwave combined with ultrasonic thawing; MIT: Microwave combined with 35 °C water immersion thawing; MRT: Microwave combined with 4 °C refrigeration thawing; MAT: Microwave combined with air convection thawing; MWT: Microwave combined with running water thawing.
Denaturation temperature Tm (°C) and enthalpy △H (J g−1) for the muscle proteins in pork samples under six different thawing conditions (analyzed by differential scanning calorimetry (DSC)).
| Thawing Ways | Peak 1 | Peak 2 | Peak 3 | |||
|---|---|---|---|---|---|---|
| Tm (°C) | △H (J g−1) | Tm (°C) | △H (J g−1) | Tm (°C) | △H (J g−1) | |
| Control | 55.76 ± 1.34 a | 0.31 ± 0.01 a | 66.26 ± 2.02 a | 0.20 ± 0.02 a | 74.26 ± 1.10 cd | 0.19 ± 0.03 ab |
| MT | 55.29 ± 0.94 a | 0.28 ± 0.02 bc | 66.80 ± 2.00 a | 0.16 ± 0.03 b | 76.30 ± 0.55 ab | 0.17 ± 0.01 bc |
| MUT | 55.10 ± 0.62 a | 0.25 ± 0.02 d | 65.10 ± 1.23 a | 0.17 ± 0.02 ab | 77.60 ± 0.83 a | 0.20 ± 0.01 ab |
| MIT | 54.62 ± 0.87 a | 0.31 ± 0.01 a | 65.62 ± 2.04 a | 0.11 ± 0.01 c | 73.12 ± 0.77 d | 0.16 ± 0.02 c |
| MRT | 55.02 ± 0.93 a | 0.26 ± 0.01 cd | 65.02 ± 2.05 a | 0.19 ± 0.01 ab | 75.52 ± 0.63 bc | 0.22 ± 0.02 a |
| MAT | 56.19 ± 0.77 a | 0.29 ± 0.01 ab | 64.19 ± 1.47 a | 0.18 ± 0.01 ab | 73.19 ± 0.90 d | 0.20 ± 0.01 ab |
| MWT | 55.65 ± 0.92 a | 0.26 ± 0.01 cd | 64.65 ± 1.79 a | 0.17 ± 0.01 ab | 76.65 ± 1.10 ab | 0.22 ± 0.02 a |
MT: Microwave thawing (100 W); MUT: Microwave combined with ultrasonic thawing; MIT: Microwave combined with 35 °C water immersion thawing; MRT: Microwave combined with 4 °C refrigeration thawing; MAT: Microwave combined with air convection thawing; MWT: Microwave combined with running water thawing. Data are means ± SE. a–d values in the same row followed by different letters are significantly different according to Duncan’s multiple range test (p < 0.05).
Figure 6Changes in dynamic storage modulus (G’ Pa) of pork samples under six different thawing conditions. MT: Microwave thawing (100 W); MUT: Microwave combined with ultrasonic thawing; MIT: Microwave combined with 35 °C water immersion thawing; MRT: Microwave combined with 4 °C refrigeration thawing; MAT: Microwave combined with air convection thawing; MWT: Microwave combined with running water thawing.