Literature DB >> 31881165

Endoscopic ultrasound guided fine needle aspiration for the diagnosis of intra-abdominal lymphadenopathy: a systematic review and meta-analysis.

Chenyu Li1,2, Yujun Shuai1,2, Xiaodong Zhou1.   

Abstract

Background: It is difficult to diagnose the cause of abdominal lymphadenopathy without determining the primary lesions. With the advent of curved ultrasound endoscopy, EUS-FNA can sample lymph nodes safely, accurately and conveniently. Due to the lack of formal quantitative and comprehensive literature review to determine the diagnostic value of EUS-FNA in the diagnosis of enlarged intra-abdominal lymph nodes of unknown origin, we conducted this study to systematically evaluate the diagnostic accuracy of EUS-FNA in the enlarged intra-abdominal lymph nodes.
Methods: We performed a systematic review and meta-analysis to evaluate the accuracy of EUS-FNA for the diagnosis of intra-abdominal lymphadenopathy. We searched PubMed, Embase, and Cochrane Library to collect related studies and diagnostic performance data. We used a random-effects model to estimate the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio (DOR). Heterogeneity was assessed by subgroup and meta-regression analysis.
Results: Twelve eligible studies involved 774 patients were identified. The pooled sensitivity and specificity of all studies is 94% (95% CI: 91% to 96%) and 98% (95% CI: 96% to 99%), respectively. The pooled positive and negative likelihood ratios are 17.44 (95% CI, 6.50 to 46.79) and 0.09 (95% CI: 0.06 to 0.14). The pooled DOR is 277.82 (95% CI, 97.65 to 790.46).Conclusions: EUS-FNA is a safe and feasible technique with high sensitivity and specificity for the diagnosis of abdominal lymph node enlargement. Considering the limitations and heterogeneity, high-quality studies are needed to further explore the diagnostic value of EUS-FNA.

Entities:  

Keywords:  Diagnosis; endoscopic ultrasound-guided fine needle aspiration; lymphadenopathy; meta-analysis

Mesh:

Year:  2019        PMID: 31881165     DOI: 10.1080/00365521.2019.1704052

Source DB:  PubMed          Journal:  Scand J Gastroenterol        ISSN: 0036-5521            Impact factor:   2.423


  3 in total

1.  High Diagnostic Accuracy and Safety of Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Malignant Lymph Nodes: A Systematic Review and Meta-Analysis.

Authors:  Linbin Chen; Yin Li; Xiaoyan Gao; Shiyong Lin; Longjun He; Guangyu Luo; Jianjun Li; Chunyu Huang; Guobao Wang; Qing Yang; Hongbo Shan
Journal:  Dig Dis Sci       Date:  2020-09-26       Impact factor: 3.199

2.  Role of endoscopic ultrasound guided fine needle aspiration/biopsy in the evaluation of intra-abdominal lymphadenopathy due to tuberculosis.

Authors:  Harshavardhan Rao B; Priya Nair; S Krishna Priya; Archana George Vallonthaiel; Dipu T Sathyapalan; Anoop K Koshy; Rama P Venu
Journal:  World J Gastrointest Endosc       Date:  2021-12-16

3.  Role of Endoscopic Ultrasound-Guided Fine-Needle Aspiration in the Evaluation of Abdominal Lymphadenopathy of Unknown Etiology.

Authors:  Nonthalee Pausawasdi; Kotchakon Maipang; Tassanee Sriprayoon; Phunchai Charatcharoenwitthaya
Journal:  Clin Endosc       Date:  2022-01-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.