Literature DB >> 31879485

Early locking plate removal following open reduction and internal fixation of proximal humeral fractures could prevent secondary implant-related complications.

Dimitris Dimitriou1, Soeren Waldmann1, Alexander Antoniadis1, Martin Liebhauser1, Naeder Helmy1, Ulf Riede1.   

Abstract

INTRODUCTION: Proximal humeral fracture is a common cause of morbidity in the elderly and poses a challenge for the orthopedic surgeon. Open reduction and internal fixation (ORIF) with a locking plate is associated with high rate of secondary implant-related complications (IRC). Early implant removal could potentially reduce the risk of IRC and further improve the outcome in relatively asymptomatic patients. The purpose of this study was to evaluate the clinical and radiologic outcomes following implant removal.
METHODS: A total of 56 patients with an average age of 63 ± 13 years and a mean follow-up of 29 months were evaluated retrospectively following removal of a locking plate in the proximal humerus. Postoperative functional outcomes were evaluated with the Constant-Score, Subjective shoulder value and Quick-DASH score.
RESULTS: Early implant removal resulted in high functional outcomes with 96% of the patients reporting an improvement of their shoulder function following implant removal. No intraoperative complications were reported. Avascular necrosis (AVN) of the humeral head occurred in 12.5% of the patients, but no secondary screw cut-out was reported.
CONCLUSION: Early implant removal might be a safe option to avoid secondary IRC with significant subjective functional improvement also in asymptomatic patients. Although early implant removal cannot reverse the process of AVN, it could potentially prevent secondary IRC and subsequent glenohumeral cartilage destruction.
© 2019 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Avascular necrosis (AVN); Clinical outcomes; Implant removal; Locking plate; Proximal humeral fracture

Year:  2019        PMID: 31879485      PMCID: PMC6919395          DOI: 10.1016/j.jor.2019.06.011

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  23 in total

Review 1.  Epidemiology of adult fractures: A review.

Authors:  Charles M Court-Brown; Ben Caesar
Journal:  Injury       Date:  2006-06-30       Impact factor: 2.586

2.  Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand) [corrected]. The Upper Extremity Collaborative Group (UECG)

Authors:  P L Hudak; P C Amadio; C Bombardier
Journal:  Am J Ind Med       Date:  1996-06       Impact factor: 2.214

Review 3.  Surgical management of complex proximal humerus fractures-a systematic review of 92 studies including 4500 patients.

Authors:  Anil K Gupta; Joshua D Harris; Brandon J Erickson; Geoffrey D Abrams; Benjamin Bruce; Frank McCormick; Gregory P Nicholson; Anthony A Romeo
Journal:  J Orthop Trauma       Date:  2015-01       Impact factor: 2.512

4.  What is the hardware removal rate after anteroinferior plating of the clavicle? A retrospective cohort study.

Authors:  Thomas P A Baltes; Johanna C E Donders; Peter Kloen
Journal:  J Shoulder Elbow Surg       Date:  2017-05-03       Impact factor: 3.019

5.  Proximal humeral internal locking system (PHILOS) for the treatment of proximal humeral fractures.

Authors:  C P Charalambous; I Siddique; K Valluripalli; M Kovacevic; P Panose; M Srinivasan; H Marynissen
Journal:  Arch Orthop Trauma Surg       Date:  2006-12-22       Impact factor: 3.067

Review 6.  Operative versus nonoperative treatment of proximal humeral fractures: a systematic review, meta-analysis, and comparison of observational studies and randomized controlled trials.

Authors:  Reinier B Beks; Yassine Ochen; Herman Frima; Diederik P J Smeeing; Olivier van der Meijden; Tim K Timmers; Detlef van der Velde; Mark van Heijl; Luke P H Leenen; Rolf H H Groenwold; R Marijn Houwert
Journal:  J Shoulder Elbow Surg       Date:  2018-05-04       Impact factor: 3.019

7.  Epidemiology of proximal humerus fractures.

Authors:  Antti P Launonen; Vesa Lepola; Aino Saranko; Tapio Flinkkilä; Minna Laitinen; Ville M Mattila
Journal:  Arch Osteoporos       Date:  2015-02-13       Impact factor: 2.617

8.  Indications for implant removal after fracture healing: a review of the literature.

Authors:  D I Vos; M H J Verhofstad
Journal:  Eur J Trauma Emerg Surg       Date:  2013-04-12       Impact factor: 3.693

9.  Elective implant removal in symptomatic patients after internal fixation of proximal humerus fractures improves clinical outcome.

Authors:  Yves P Acklin; Christian Michelitsch; Christoph Sommer
Journal:  BMC Musculoskelet Disord       Date:  2016-03-10       Impact factor: 2.362

10.  Outcome analysis following removal of locking plate fixation of the proximal humerus.

Authors:  Chlodwig Kirchhoff; Volker Braunstein; Sonja Kirchhoff; Christoph M Sprecher; Ben Ockert; Florian Fischer; Bernd A Leidel; Peter Biberthaler
Journal:  BMC Musculoskelet Disord       Date:  2008-10-12       Impact factor: 2.362

View more
  4 in total

1.  Proximal humeral fracture-dislocation: Outcome analysis in osteosynthesis and arthroplasties.

Authors:  Samuel Haupt; Sabrina Weber; Herman Frima; René Hutter; Holger Grehn; Christoph Sommer
Journal:  Eur J Orthop Surg Traumatol       Date:  2022-01-15

2.  Functional outcomes before and after implant removal in patients with posttraumatic shoulder stiffness and healed proximal humerus fractures: does implant material (PEEK vs. titanium) have an impact? - a pilot study.

Authors:  E Fleischhacker; C M Sprecher; S Milz; M M Saller; J Gleich; G Siebenbürger; T Helfen; W Böcker; B Ockert
Journal:  BMC Musculoskelet Disord       Date:  2022-01-27       Impact factor: 2.362

Review 3.  Elective removal vs. retaining of hardware after osteosynthesis in asymptomatic patients-a scoping review.

Authors:  Barbara Prediger; Tim Mathes; Christian Probst; Dawid Pieper
Journal:  Syst Rev       Date:  2020-10-02

4.  Is Device Removal Necessary after Fixed-Angle Locking Plate Osteosynthesis of Proximal Humerus Fractures?

Authors:  Beom-Soo Kim; Du-Han Kim; Jung-Hoon Choi; Byung-Chan Choi; Chul-Hyun Cho
Journal:  Medicina (Kaunas)       Date:  2022-03-04       Impact factor: 2.430

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.