Literature DB >> 31873956

"Comparative intra- and inter-rater reliability of maximal voluntary contraction with unidigital and bidigital vaginal palpation and construct validity with Peritron manometer".

Jordana B da Silva1, Tatiana O Sato2, Ana P R Rocha1, Patricia Driusso1.   

Abstract

AIMS: Evaluate the intra- and inter-rater reliability of maximal voluntary contraction (MVC) of pelvic floor muscle (PFM) assessment by unidigital and bidigital vaginal palpation. As a secondary aim, evaluate the construct validity of vaginal palpation and a manometer.
METHODS: A total of 120 women were recruited and allocated into three groups according to age (group 1 [G1]: 18-35; G2: 36-59; G3: ≥60 years). Examiner A conducted an interview and examiners B and C performed evaluations of PFM function using both unidigital and bidigital vaginal palpation. Seven to 10 days later, examiner B repeated both types of vaginal palpation and measured the MVC pressure with a Peritron. Reliability was analyzed using Cohen's linear weighted Kappa (κw ). The construct validity was calculated using the Spearman's correlation (rs ).
RESULTS: Intra-rater reliability of unidigital and bidigital palpation was κw  = 0.75 and κw  = 0.58 in G1, κw  = 0.59 and κw  = 0.73 in G2, and κw  = 0.79 and κw  = 0.86 in G3, respectively. Inter-rater reliability of unidigital and bidigital palpation was κw  = 0.52 and κw  = 0.48 in G1, κw  = 0.47 and κw  = 0.52 in G2, and κw  = 0.50 and κw  = 0.64 in G3, respectively. Spearman's correlation coefficients were significant at rs  = 0.79 and rs  = 0.80 for unidigital and bidigital vaginal palpation, respectively.
CONCLUSIONS: Unidigital or bidigital vaginal palpation were indicated to evaluate G1 and G2 but bidigital palpation was more reliable in G3 when two examiners performed the evaluation. For the assessment conducted by one examiner, unidigital palpation was more reliable in G1 while bidigital palpation was more reliable in G2 and G3. Both unidigital and bidigital palpation have high measures of validity.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  manometry; outcome and process assessment; palpation; pelvic floor; reproducibility of results; strength

Mesh:

Year:  2019        PMID: 31873956     DOI: 10.1002/nau.24263

Source DB:  PubMed          Journal:  Neurourol Urodyn        ISSN: 0733-2467            Impact factor:   2.696


  3 in total

1.  Reliability of the PERFECT scheme assessed by unidigital and bidigital vaginal palpation.

Authors:  Jordana Barbosa da Silva; Jéssica Gabriela de Godoi Fernandes; Bruna Raquel Caracciolo; Sara Campana Zanello; Tatiana de Oliveira Sato; Patricia Driusso
Journal:  Int Urogynecol J       Date:  2021-01-08       Impact factor: 2.894

2.  Comparing the efficacy of the Knack maneuver on pelvic floor muscle function and urinary symptoms using different teaching methods: a prospective, nonrandomized study.

Authors:  Seda Yakıt Yeşilyurt; Nuriye Özengin; M Ata Topçuoğlu
Journal:  Int Urogynecol J       Date:  2022-05-02       Impact factor: 1.932

3.  Is there agreement between the preference of examiner and women for unidigital and bidigital vaginal palpation? A qualitative study.

Authors:  Jordana Barbosa da Silva; Ana Paula Rodrigues Rocha; Tatiana de Oliveira Sato; Patricia Driusso
Journal:  Int Urogynecol J       Date:  2021-07-30       Impact factor: 2.894

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.