Literature DB >> 31872249

Safety and outcome of very high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation.

Marc Kottmaier1, Miruna Popa1, Felix Bourier1, Tilko Reents1, Jairo Cifuentes1, Verena Semmler1, Martha Telishevska1, Ulamnemekh Otgonbayar1, Katharina Koch-Büttner1, Carsten Lennerz1, Marcin Bartkowiak1, Marielouise Kornmayer1, Elena Rousseva1, Amir Brkic1, Christian Grebmer1, Christoph Kolb1, Gabriele Hessling1, Isabel Deisenhofer1.   

Abstract

AIMS: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) in patients with paroxysmal atrial fibrillation (PAF) is effective but hampered by pulmonary vein reconnection due to insufficient ablation lesions. High-power delivery over a short period of time (HPSD) in RFA is stated to create more efficient lesions. The aim of this study was to compare intraprocedural safety and outcome of HPSD ablation to conventional power settings in patients undergoing PVI for PAF. METHODS AND
RESULTS: We included 197 patients with PAF that were scheduled for PVI. An ablation protocol with 70 W and a duration cut-off of 7 s at the anterior left atrium (LA) and 5 s at the posterior LA (HPSD group; n = 97) was compared to a conventional power protocol with 30-40 W for 20-40 s (standard group; n = 100) in terms of periprocedural complications and a 1-year outcome. The HPSD group showed significantly less arrhythmia recurrence during 1-year follow-up with 83.1% of patients free from atrial fibrillation compared to 65.1% in the standard group (P < 0.013). No pericardial tamponade, periprocedural thromboembolic complications, or atrio-oesophageal fistula occurred in either group. Mean radiofrequency time (12.4 ± 3.4 min vs. 35.6 ± 12.1 min) and procedural time (89.5 ± 23.9 min vs. 111.15 ± 27.9 min) were significantly shorter in the HPSD group compared to the standard group (both P < 0.001).
CONCLUSION: High-power short-duration ablation demonstrated a comparable safety profile to conventional ablation. High-power short-duration ablation using 70 W for 5-7 s leads to significantly less arrhythmia recurrences after 1 year. Radiofrequency and procedural time were significantly shortened. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author(s) 2019. For permissions, please email: journals.permissions@oup.com.

Entities:  

Keywords:  Atrial fibrillation ablation; High-power short-duration ablation; Pulmonary vein isolation; Radiofrequency ablation

Mesh:

Year:  2020        PMID: 31872249     DOI: 10.1093/europace/euz342

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  24 in total

1.  [Pulmonary vein isolation using radiofrequency ablation].

Authors:  Leon Iden; Sonia Busch; Daniel Steven; Roland R Tilz; Dong-In Shin; K R Julian Chun; Heidi Estner; Felix Bourier; David Duncker; Philipp Sommer; Andreas Metzner; Tilman Maurer; Nils-Christian Ewertsen; Henning Jansen; Andreas Rillig; Victoria Johnson; Till Althoff
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2021-07-26

Review 2.  [Catheter ablation : Developments and technique selection].

Authors:  L Yahsaly; J Siebermair; R Wakili
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2022-02-18

3.  Meta-analysis comparing outcomes of high-power short-duration and low-power long-duration radiofrequency ablation for atrial fibrillation.

Authors:  Dibbendhu Khanra; Abdul Hamid; Saurabh Deshpande; Anindya Mukherjee; Sanjiv Petkar; Mohammad Saeed; Indranill Basu-Ray
Journal:  Anatol J Cardiol       Date:  2022-01       Impact factor: 1.596

Review 4.  Prophylactic Cavotricuspid Isthmus Ablation in Atrial Fibrillation without Documented Typical Atrial Flutter: A Systematic Review and Meta-analysis.

Authors:  Yoga Waranugraha; Ardian Rizal; Mohammad Saifur Rohman; Chia-Ti Tsai; Fu-Chun Chiu
Journal:  Arrhythm Electrophysiol Rev       Date:  2022-04

Review 5.  Catheter ablation for atrial fibrillation: current indications and evolving technologies.

Authors:  Ramanathan Parameswaran; Ahmed M Al-Kaisey; Jonathan M Kalman
Journal:  Nat Rev Cardiol       Date:  2020-10-13       Impact factor: 32.419

Review 6.  Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial Fibrillation.

Authors:  Xuerong Sun; Jiang Lu; Jinxuan Lin; Tianjie Feng; Ni Suo; Lihui Zheng; Zhimin Liu; Gang Chen; Xiaohan Fan; Shu Zhang; Guodong Niu
Journal:  Cardiol Res Pract       Date:  2021-02-15       Impact factor: 1.866

7.  Very high-power short-duration temperature-controlled ablation versus conventional power-controlled ablation for pulmonary vein isolation: The fast and furious - AF study.

Authors:  Roland Richard Tilz; Makoto Sano; Julia Vogler; Thomas Fink; Roza Saraei; Vanessa Sciacca; Bettina Kirstein; Huong-Lan Phan; Sascha Hatahet; Lisbeth Delgado Lopez; Anna Traub; Charlotte Eitel; Michael Schlüter; Karl-Heinz Kuck; Christian-Hendrik Heeger
Journal:  Int J Cardiol Heart Vasc       Date:  2021-07-26

8.  Safety and Efficacy of High Power Shorter Duration Ablation Guided by Ablation Index or Lesion Size Index in Atrial Fibrillation Ablation: A Systematic Review and Meta-Analysis.

Authors:  Xing Liu; Chun Gui; Weiming Wen; Yan He; Weiran Dai; Guoqiang Zhong
Journal:  J Interv Cardiol       Date:  2021-06-02       Impact factor: 2.279

9.  Comparison of high-power and conventional-power radiofrequency energy deliveries in pulmonary vein isolation using unipolar signal modification as a local endpoint.

Authors:  Koichiro Ejima; Satoshi Higuchi; Kyoichiro Yazaki; Shohei Kataoka; Daigo Yagishita; Miwa Kanai; Morio Shoda; Nobuhisa Hagiwara
Journal:  J Cardiovasc Electrophysiol       Date:  2020-05-15

10.  Triple gastrointestinal prophylactic therapy following high-power short-duration posterior left atrial wall ablation.

Authors:  Basar Candemir; Emir Baskovski; Mammad Mammadov; Kerim Esenboga; Timucin Altin
Journal:  Indian Heart J       Date:  2020-07-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.