| Literature DB >> 31871962 |
C Boschmann Käthler1, U M Angst1, A M Aguilar1, B Elsener1,2.
Abstract
A living data collection providing critical chloride contents for steel corrosion in concrete (Ccrit) is presented. The Ccrit values were measured on samples taken from engineering structures. This approach allows to overcome the well-known limitations of testing laboratory samples. The data are available in a public data repository. Currently, 46 Ccrit are reported (measured on four different structures). The database will continuously be updated. The database includes information about the structure, material properties, and local condition of the steel-concrete interface. For possible applications of this database and discussion refer to the related research article in Corrosion Science.Entities:
Keywords: Carbon steel; Concrete; Critical chloride content; Pitting corrosion; Steel reinforced concrete
Year: 2019 PMID: 31871962 PMCID: PMC6915792 DOI: 10.1016/j.dib.2019.104675
Source DB: PubMed Journal: Data Brief ISSN: 2352-3409
Summary of information reported in the data file. For further explanation, see Chapter 2.2 to 2.5
| Reported information | Remarks | |
|---|---|---|
| Sample identification number | Each tested sample has an identification number to permit unambiguous assignments ( | |
| Engineering structure information | Year of construction | based on documents about structure |
| Location | Geographic location of the structure | |
| Meters above sea level (m a.s.l.) | according to geographic location | |
| Type of structure | e.g. tunnel, bridge, etc. | |
| Element | The type of structural member from which the samples were taken (e.g. tunnel wall, tunnel ceiling, abutment wall, bridge deck/slab, etc.) (compare | |
| Exposure class | According to EN Standard EN 206-1 | |
| Area of sampling (m2) | Size of area (in m2 of concrete surface), within which drilling cores were taken. This area applies to each sample series within an element (compare | |
| Concrete information | Cover depth (mm) | Cover depth measured on the drilling cores immediately after sampling from the structure |
| Cement type | based on available documentation or characterization of obtained samples | |
| w/b-ratio | based on available documentation or characterization of obtained samples | |
| aggregates | based on available documentation or characterization of obtained samples | |
| Compressive strength (MPa) | Compressive strength of concrete according to documentation of structure or measured on additional samples | |
| Concrete resistivity (Ωm) | In wet conditions, measured during the corrosion test in the laboratory | |
| Non-carbonated cover depth (mm) | Distance from the carbonation front (phenolphthalein spray test) to the steel, measured on the drilling cores after splitting the sample | |
| pH of pore solution at level of reinforcement | Measured on the drilling cores after splitting the sample as described in [ | |
| Steel information | Steel bar diameter (mm) | measured on the sample |
| Orientation of reinforcement in the structure | Horizontal (H) or vertical (V), see Figure 2 | |
| Type of steel | Qualitative information about steel, such as chemical composition, and rib geometry | |
| Microstructure near surface | in the zone close to the surface | |
| Steel potential information (mV vs. Ag/AgClsat) | Measured in the laboratory at the beginning of chloride exposure testing, before corrosion initiation, and at the end of the corrosion test | |
| Critical chloride content (% by mass of concrete and of binder) | Acid-soluble chloride content at level of reinforcement | |
| Steel-concrete interface (SCI) | Visually observable characteristics at the initiation spot on the concrete | Irregularities such as pores, cracks, tie wires, etc. at the SCI |
| Visually observable characteristics elsewhere on the concrete | Irregularities such as pores, cracks, tie wires, etc. at the SCI, but at locations where no corrosion initiated | |
| Visually observable characteristics at the initiation spot on the steel | This includes mainly if the initiation spot is on a rib, adjacent to a rib, or between the ribs. | |
| Location of corrosion initiation with respect to the rebar orientation in the structure | See | |
| Laboratory | Name of the laboratory that conducted the test (chloride exposure of drilling cores in the lab and analysis) | |
Abbreviations used in the data collection.
| Abbreviation | Meaning |
|---|---|
| Orientation of reinforcement in the structure | |
| V | vertical |
| H | horizontal |
| Characteristics on the concrete interface | |
| N | nothing |
| A | air void (<1 mm) |
| CA | coarse air void (>1 mm) |
| A or CA | initiation spot at A or CA |
| A-E or CA-E | initiation spot at the edge of A or CA |
| D | deposit |
| CE | crack from steel to exposure side |
| CR | cracks at SCI at ribs |
| W | tie wire |
| Characteristics at the steel interface | |
| R | rib |
| aR | adjacent to rib |
| bR | between ribs |
| Orientation of corrosion initiation with respect to structure | |
| S | side |
| U | upper side |
| L | lower side |
| Others | |
| NR | not reported |
| PC | Portland cement |
| SCI | steel-concrete interface |
Fig. 1Structure of labelling of each specific sample.
Fig. 2Labelling of orientation of exposed side of horizontal reinforcement. The grey areas below the rebar represent the region of plastic settlement, where special conditions at the SCI might occur [10].
Fig. 3Illustration of different kinds of air voids and cracks.
Specifications Table
| Subject area | |
| More specific subject area | |
| Type of data | |
| How data was acquired | |
| Data format | |
| Experimental factors | |
| Experimental features | |
| Data source location | |
| Data accessibility | |
| Related research article |
This data is important for understanding and predicting corrosion of steel in concrete. The reported data was obtained with a single, well-defined method and contains all relevant parameters on corrosion susceptibility. Civil engineers can use the data as input parameter for service life design. The data can be used by corrosion scientists to enhance the fundamental understanding of corrosion initiation. Using specimens from engineering structures ensures realistic conditions at the steel-concrete interface. While this is crucial, it cannot be achieved in experiments with specimens produced in the laboratory. |