Literature DB >> 31870612

Intraoral digital scans: Part 2-influence of ambient scanning light conditions on the mesh quality of different intraoral scanners.

Marta Revilla-León1, Peng Jiang2, Mehrad Sadeghpour3, Wenceslao Piedra-Cascón4, Amirali Zandinejad5, Mutlu Özcan6, Vinayak R Krishnamurthy7.   

Abstract

STATEMENT OF PROBLEM: Digital scans should be able to accurately reproduce the different complex geometries of the patient's mouth. Mesh quality of the digitized mouth is an important factor that influences the capabilities of the geometry reproduction of an intraoral scanner (IOS). However, the mesh quality capabilities of IOSs and the relationship with different ambient light scanning conditions are unclear.
PURPOSE: The purpose of this in vitro study was to measure the impact of various light conditions on the mesh quality of different IOSs.
MATERIAL AND METHODS: Three IOSs were evaluated-iTero Element, CEREC Omnicam, and TRIOS 3-with 4 lighting conditions-chair light, 10 000 lux; room light, 1003 lux; natural light, 500 lux; and no light, 0 lux. Ten digital scans per group were made of a mandibular typodont. The mesh quality of digital scans was analyzed by using the iso2mesh MATLAB package. Two-way ANOVA and Kruskal-Wallis 1-way ANOVA statistical tests were used to analyze the data (á=.05).
RESULTS: Significant differences in mesh quality values were found among the different IOSs under the same lighting conditions and among the different lighting conditions using the same IOS. TRIOS 3 showed the highest consistency and mesh quality mean values across all scanning lighting conditions tested. CEREC Omnicam had the lowest mean mesh quality values across all scanning lighting conditions. iTero Element displayed some consistency in the mesh quality values depending on the scanning lighting conditions: chair light and room light conditions presented good consistency in mesh quality, indicating better mesh quality, and natural light and no light conditions displayed differing consistency in mesh quality values. Nevertheless, no light condition led to the minimal mean mesh quality across all IOS groups.
CONCLUSIONS: Differences in the mesh quality between different IOSs should be expected. The photographic scanning techniques evaluated presented higher mesh quality mean values than the video-based scanning technology tested. Moreover, changes in lighting condition significantly affect mesh quality. TRIOS 3 showed the highest consistency in terms of the mean mesh quality, indicating better photographic system in comparison with iTero Element.
Copyright © 2019 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31870612     DOI: 10.1016/j.prosdent.2019.06.004

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  Scanning Distance Influence on the Intraoral Scanning Accuracy-An In Vitro Study.

Authors:  Raul Nicolae Rotar; Andrei Bogdan Faur; Daniel Pop; Anca Jivanescu
Journal:  Materials (Basel)       Date:  2022-04-22       Impact factor: 3.748

2.  Effect of the volumetric dimensions of a complete arch on the accuracy of scanners.

Authors:  Min-Kyu Kim; KeunBaDa Son; Beom-Young Yu; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2020-12-28       Impact factor: 1.904

Review 3.  Pros and Cons of CAD/CAM Technology for Infection Prevention in Dental Settings during COVID-19 Outbreak.

Authors:  Livia Barenghi; Alberto Barenghi; Umberto Garagiola; Alberto Di Blasio; Aldo Bruno Giannì; Francesco Spadari
Journal:  Sensors (Basel)       Date:  2021-12-22       Impact factor: 3.576

4.  Analysis of the relationship between the surface topography of prepared tooth surfaces and data quality of digital impressions from an intraoral scanner.

Authors:  Neset Volkan Asar; Sarah Yun; Shelby Schwartz; Ilser Turkyilmaz
Journal:  J Dent Sci       Date:  2021-07-31       Impact factor: 2.080

5.  In Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systems.

Authors:  Jaime Orejas-Perez; Beatriz Gimenez-Gonzalez; Ignacio Ortiz-Collado; Israel J Thuissard; Andrea Santamaria-Laorden
Journal:  Int J Environ Res Public Health       Date:  2022-04-03       Impact factor: 3.390

6.  Can Dental Office Lighting Intensity Conditions Influence the Accuracy of Intraoral Scanning?

Authors:  Anca Jivanescu; Andrei-Bogdan Faur; Raul Nicolae Rotar
Journal:  Scanning       Date:  2021-05-27       Impact factor: 1.932

7.  Effect of Tooth Types on the Accuracy of Dental 3D Scanners: An In Vitro Study.

Authors:  Keunbada Son; Kyu-Bok Lee
Journal:  Materials (Basel)       Date:  2020-04-09       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.