Literature DB >> 31870519

Virtual planning, simultaneous dental implantation and CAD/CAM plate fixation: a paradigm change in maxillofacial reconstruction.

T Seier1, L Hingsammer2, P Schumann2, T Gander2, M Rücker2, M Lanzer2.   

Abstract

Prosthetic rehabilitation in patients undergoing reconstructive surgery using vascularized free flaps is challenging, and functional rehabilitation of the patient with a fixed prosthesis is rare. Virtually planned maxillofacial reconstruction including simultaneous dental implantation according to the prosthodontic ideal position of the implants could further enhance dental rehabilitation. The data of 21 patients undergoing fibula free flap reconstructive surgery with CAD/CAM patient-specific reconstruction plates during the years 2015-2018 were analysed, including the applicability of the virtual plan, flap survival, duration of surgery, ischemia time, simultaneous dental implantation, implant exposure, and postoperative complications. The virtual plan could be translated to surgery in all cases. In total, 76 dental implants were simultaneously placed during primary reconstruction in the 21 patients. For 38.1% of these patients, the implants could be uncovered in secondary surgery; the mean duration until exposure was 7.6 months. The implant survival rate was 97.4% (74/76). Wound infection requiring a secondary intervention occurred in 23.8% of patients during follow-up. Virtually planned reconstruction with a fibula free flap, simultaneous dental implantation, and CAD/CAM plates allows early and functional dental rehabilitation. A dental workflow should be integrated into the virtual planning, and prosthetically favourable implant positions should determine the position of the fibula segments.
Copyright © 2019 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  CAD/CAM plates; dental implants; fibula free flap; reconstruction; virtual planning

Mesh:

Year:  2019        PMID: 31870519     DOI: 10.1016/j.ijom.2019.11.010

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  1 in total

1.  [Application of personalized guide plate combined with real-time navigation in repairing mandibular defect using fibula muscle flap].

Authors:  Tingyi Gao; Dong Wang; Mo Chen; Zhaojun Zhan; Xiao Peng; Kai Zhang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-06-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.