Literature DB >> 31868992

Automated Dynamic Clamp for Simulation of IK1 in Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes in Real Time Using Patchliner Dynamite8.

Nadine Becker1, András Horváth1, Teun De Boer2, Alan Fabbri2, Christian Grad1, Niels Fertig1, Michael George1, Alison Obergrussberger1.   

Abstract

Current in vitro assays typically poorly predict cardiac liability as they focus on single ion channels overexpressed in cell lines. Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs), on the other hand, provide a unique opportunity for drug testing on human cardiomyocytes using high-throughput systems. However, these cells can differ from adult cardiomyocytes in their ion channel expression and, therefore, electrophysiologic properties. One of the main challenges of hiPSC-CMs is the physiologic expression of ion channels such as the inward rectifiers (e.g., Kir2.1-2.3), which conduct the cardiac inward rectifier potassium current (IK1 ). IK1 is one of the primary contributors in maintaining a stable resting membrane potential in cardiac cells, which is essential for excitability. This is only expressed in low levels, or sometimes not at all, in hiPSC-CMs as shown by patch clamp studies. Dynamic clamp is a method of electronically introducing ion currents (e.g., IK1 ) into cells to compensate for the lack of endogenous expression, thus offering the potential to record more stable action potentials in hiPSC-CMs. In this article, we describe the method of using hiPSC-CMs on an automated patch clamp device (Patchliner) coupled with the automated dynamic clamp add-on (Dynamite8 ). We describe protocols for optimized cell handling and harvesting for use on the Patchliner and the steps required for automated execution of experiments and data analysis in dynamic clamp mode.
© 2019 by John Wiley & Sons, Inc. Basic Protocol: Recording action potential pharmacology from human induced pluripotent stem cell-derived cardiomyocytes in automated patch clamp combined with dynamic clamp to introduce simulated IK1 and compensate seal resistance Support Protocol 1: Cardiomyocyte plating and culture Support Protocol 2: Cell harvesting and dissociation Alternate Protocol: Recording action potential pharmacology at physiologic temperatures. © 2019 John Wiley & Sons, Inc.

Entities:  

Keywords:  Patchliner; automated patch clamp; dynamic clamp; human induced pluripotent stem cell-derived cardiomyocytes; inward rectifier potassium current

Mesh:

Substances:

Year:  2020        PMID: 31868992     DOI: 10.1002/cpph.70

Source DB:  PubMed          Journal:  Curr Protoc Pharmacol        ISSN: 1934-8282


  3 in total

1.  Advancing Ion Channel Research with Automated Patch Clamp (APC) Electrophysiology Platforms.

Authors:  Damian C Bell; Mark L Dallas
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

Review 2.  Adventures and Advances in Time Travel With Induced Pluripotent Stem Cells and Automated Patch Clamp.

Authors:  Kadla R Rosholm; Beatrice Badone; Stefania Karatsiompani; David Nagy; Fitzwilliam Seibertz; Niels Voigt; Damian C Bell
Journal:  Front Mol Neurosci       Date:  2022-06-22       Impact factor: 6.261

3.  Investigation of the Effects of the Short QT Syndrome D172N Kir2.1 Mutation on Ventricular Action Potential Profile Using Dynamic Clamp.

Authors:  Chunyun Du; Randall L Rasmusson; Glenna C Bett; Brandon Franks; Henggui Zhang; Jules C Hancox
Journal:  Front Pharmacol       Date:  2022-01-18       Impact factor: 5.810