| Literature DB >> 31867610 |
Zumre Arican Alickikus1, Ahmet Kuru1, Barbaros Aydin1, Dogukan Akcay1, Ilknur Bilkay Gorken1.
Abstract
New precision radiotherapy (RT) techniques reduce the uncertainties in localizing soft and moving tumors. However, there are still many uncontrollable internal organ movements. In our study, patients who underwent neoadjuvant chemoradiotherapy (NA-CRT) for rectal cancer were evaluated to determine inter-fraction mesorectum motion and dosimetric changes. Fourteen patients treated with NA-CRT for rectal cancer between 2014 and 2016 were included in the analysis. The mesorectum and clinical target volume (CTV) were delineated on planning computed tomography (CT) and cone-beam CT (CB-CT) scans. After planning with a volumetric modulated arc therapy (VMAT) plan, re-planning was performed on all CB-CTs. Finally, the volumetric and dosimetric changes of PTV and mesorectum were evaluated in all CB-CTs compared with the initial CT and VMAT plans. The geometrical center of mesorectum volume in CB-CTs had moved 1 (0.2-6.6), 1.6 (0.2-3.8) and 1.6 (0-4.9) mm in the x, y and z-axis respectively compared with the initial CT. The dosimetric parameters of PTV including D2, D95 and D98 on CB-CT showed a median 47.19 (46.70-47.80), 45.05 (44.18-45.68) and 44.69 (43.83-45.48) Gy and median 1% (1-2), 0% (0-2) and 1% (0-2) dosimetric change compared with the initial VMAT plan. In our study, we have shown that the mesorectum has moved up to 20 mm in the lateral and anterior-posterior direction and almost 10 mm in the superior/inferior direction during RT, causing a median of ~2% change in dosimetric parameters. Therefore, these movements must be considered in determining PTV margins to avoid dosimetric changes.Entities:
Keywords: Rectal cancer; dosimetric changes; mesorectum; radiotherapy
Year: 2020 PMID: 31867610 PMCID: PMC7246061 DOI: 10.1093/jrr/rrz092
Source DB: PubMed Journal: J Radiat Res ISSN: 0449-3060 Impact factor: 2.724
Patient and tumor characteristics (n = 14)
|
|
|
|
|---|---|---|
|
| ||
| Male | 11 | 78 |
| Female | 3 | 22 |
|
| ||
| T2 | 1 | 7.1 |
| T3a | - | - |
| T3b | 9 | 64.3 |
| T3c | 3 | 21.5 |
| T3d | 1 | 7.1 |
|
| ||
| N0 | 2 | 14.2 |
| N+ | 12 | 85.8 |
Fig. 1Changes in mesorectum contours on cone-beam CT images matched to planning CT scans (P-CT, CB-CT 1, CB-CT 2, CB-CT 3, and CB-CT 4)
The median shift in the geometric center of the mesorectal volume of patients in x, y and z axes
| Patient | T stage | ∆ | ∆ | ∆ |
|---|---|---|---|---|
| 1 | T2 | 0.3 | 0.2 | 0.2 |
| 2 | T3b | 6.6 | 2.4 | 0.5 |
| 3 | T3b | 1.4 | 3.1 | 0.4 |
| 4 | T3b | 1.5 | 1.8 | 3.6 |
| 5 | T3b | 0.3 | 0.9 | 0.0 |
| 6 | T3b | 0.7 | 1.9 | 2.2 |
| 7 | T3b | 1.6 | 2.4 | 0.7 |
| 8 | T3b | 2.8 | 1.6 | 4.9 |
| 9 | T3b | 0.2 | 0.7 | 2.4 |
| 10 | T3b | 2.5 | 3.8 | 3.3 |
| 11 | T3c | 1.0 | 1.3 | 1.9 |
| 12 | T3c | 0.2 | 1.6 | 0.5 |
| 13 | T3c | 1.0 | 0.7 | 2.8 |
| 14 | T3d | 0.8 | 1.0 | 1.2 |
| Median | 1.0 | 1.6 | 1.6 | |
Rectal cancer IGRT studies showing the magnitude of motion and region studied
|
|
|
|
|
|
|---|---|---|---|---|
| Brierley | 17 | p-CT scans at weeks 1, 3 and 5 | Left-right (mean): 1.2; anterior–posterior (mean): 0.7; superior–inferior (mean): 4.2 | Rectum and mesorectum |
| Tournel | 10 | CT scan (tomotherapy) | Left-right (mean): 1.6; anterior–posterior (mean): 2.0; superior–inferior (mean): 3.2 | Mesorectum |
| DeNittis | 9 | Weekly CT scans | Left–right (mean): 4.4; anterior–posterior (mean): 6.0 | Rectum |
| Lee | 9 | Daily cone-beam CT | Lateral (max): 26; anterior–posterior (max): 37.7 | Rectum |
| Ippolito | 20 | Weekly CT scans | Maximum deviation (mean): 74 cc | Rectum |
| Nuyttens | 10 | Weekly CT scans | Cranial (mean): 10; caudal (mean): 15 | Rectum, perirectal tissues and regional lymphatics |
Mesorectum volumes and the mean % change in the mesorectal volume in cone beam-CT considering the planning-CT [(+): increase, (−): decrease]
|
|
|
|
| ||||
|---|---|---|---|---|---|---|---|
|
|
|
|
|
| |||
| 1 | T2 | 389.50 | 417.90 | 368.60 | 372.30 | 364.30 | −2.24 |
| 2 | T3b | 337.00 | 379.00 | 353.60 | 368.10 | 386.40 | +10.32 |
| 3 | T3b | 375.50 | 349.60 | 373.80 | 357.10 | 349.10 | −4.82 |
| 4 | T3b | 373.40 | 423.50 | 410.40 | 395.50 | 443.10 | +11.98 |
| 5 | T3b | 379.30 | 407.20 | 344.50 | 397.20 | 344.60 | −1.56 |
| 6 | T3b | 339.20 | 339.80 | 369.80 | 379.20 | 326.00 | +4.27 |
| 7 | T3b | 265.90 | 289.10 | 291.90 | 298.60 | 277.50 | +8.79 |
| 8 | T3b | 372.00 | 377.30 | 368.60 | 367.70 | 351.60 | −1.53 |
| 9 | T3b | 276.90 | 312.70 | 262.00 | 280.00 | 325.70 | +6.57 |
| 10 | T3 | 272.40 | 385.10 | 353.10 | 334.20 | 314.10 | +27.25 |
| 11 | T3c | 218.40 | 273.60 | 298.20 | 307.30 | 297.30 | +34.66 |
| 12 | T3c | 351.70 | 401.00 | 437.90 | 465.10 | 398.10 | +20.99 |
| 13 | T3c | 330.50 | 340.20 | 398.90 | 342.20 | 339.00 | +7.44 |
| 14 | T3d | 374.00 | 400.30 | 415.40 | 372.80 | 369.10 | +4.12 |
| Median | 345.45 (218-389) | 378.15 (273–424) | 368.60 (262–438) | 367.90 (280–465) | 346.85 (277–443) | +7.01 | |
| Mean | 332.55 | 364.02 | 360.48 | 359.81 | 348.99 | +5.76 | |
The percentage (%) of changes in the mesorectum mean doses according to VMAT planning calculated using cone beam-CT images [(+): increase. (−): decrease). p-Dx: x doses in planning CT. CB-CT-Dx: x doses in cone beam-CT.
|
| ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | T2 | 45.0 | 45.3 | −1 | 45.2 | 45.6 | −1 | 46.7 | 47.5 | −2 |
| 2 | T3b | 44.8 | 44.2 | +1 | 45.0 | 44.9 | +1 | 46.6 | 47.0 | −1 |
| 3 | T3b | 44.9 | 44.3 | +1 | 45.0 | 45.4 | −1 | 46.7 | 47.8 | −2 |
| 4 | T3b | 44.8 | 43.8 | +2 | 45.0 | 44.2 | +2 | 46.8 | 46.7 | 0 |
| 5 | T3b | 44.9 | 44.6 | +1 | 45.0 | 44.9 | 0 | 46.8 | 47.1 | −1 |
| 6 | T3b | 44.9 | 44.2 | +2 | 45.0 | 44.5 | +1 | 46.9 | 47.1 | 0 |
| 7 | T3b | 45.0 | 44.2 | +2 | 45.1 | 44.5 | +1 | 46.7 | 46.7 | 0 |
| 8 | T3b | 45.0 | 45.5 | −1 | 45.1 | 45.7 | −1 | 46.7 | 47.4 | −1 |
| 9 | T3b | 45.0 | 44.8 | +1 | 45.1 | 45.2 | 0 | 46.7 | 47.3 | −1 |
| 10 | T3b | 45.0 | 45.1 | 0 | 45.1 | 45.3 | 0 | 46.8 | 47.3 | −1 |
| 11 | T3c | 45.1 | 45.1 | 0 | 45.2 | 45.3 | 0 | 47.0 | 47.3 | −1 |
| 12 | T3c | 44.8 | 45.1 | −1 | 44.9 | 45.2 | −1 | 46.8 | 47.2 | −1 |
| 13 | T3c | 45.0 | 44.9 | 0 | 45.1 | 45.2 | 0 | 47.0 | 47.2 | +1 |
| 14 | T3d | 45.0 | 44.8 | 0 | 45.1 | 45.1 | 0 | 46.8 | 47.1 | −1 |
| Median | 45.00 (44.8–45.1) | 44.8 (43.8–44.8) | 1 (0–2) | 45.1 (44.9–45.2) | 45.2 (44.2–45.1) | 0 (0-2) | 46.8 (46.6–47.0) | 47.2 (46.7–47.1) | 1 (0–2) | |
Fig. 2Re-planning with VMAT on cone-beam CT and dose distribution for the mesorectal volume. Mesorectum contour has moved beyond the planned 95% isodose line on CB-CT with an up to 30% dose decrease according to planned dose.
Bladder volume changes in CB-CT according to P-CT
|
|
|
| |
|---|---|---|---|
|
| 196 (67–328) | −13 (Range −44 to +113) | −2 |
|
| 162 (48–290) | −37 (Range −61 to +59) | −22 |
|
| 99 (47–320) | −34 (Range −75 to +15) | −32 |
|
| 165 (43–410) | −30 (Range −68 to +143) | −4 |
|
| - | −19 (Range −52 to +42) | −15 |