E Nandini1, B Arunraj2, N Rajesh2, Vidya Rajesh1. 1. Department of Biological Sciences, Birla Institute of Technology and Science, Pilani-Hyderabad Campus, Hyderabad, 500 078, India. 2. Department of Chemistry, Birla Institute of Technology and Science, Pilani-Hyderabad Campus, Hyderabad, 500 078, India.
Abstract
Gut microbiota has been implicated in many disorders including Autism Spectrum Disorder (ASD). ASD is a neurodevelopmental brain disorder affecting individuals leading to restricted and repetitive pattern of behaviour and disruption of communication and social interactions. Altered microbiome and the presence or absence of key species capable of affecting specific responses in levels of their fermentation products are reflected in the urinary metabolite profile of patients. The aim of our study is to develop an improvised method for the detection and quantification of urinary p-cresol levels which could serve as an indicator for GI microbial dysbiosis. The p-cresol analysis was achieved using HPLC by a reverse phase C18 column with mobile phase composition of Acetonitrile/water/formic acid (10:90:0.05, v/v/v) in an isocratic mode of elution with a flow rate of 1.0 mL/min. The mass analysis of p-cresol was performed using LC-MS [Triple Quadrupole Liquid Chromatography Mass Spectrometer] in negative ESI mode with electron multiplier detector. p-cresol was eluted at a retention time of approximately 3.4 min. The standard calibration curves had a superior regression coefficient of greater than 0.99 (R2 > 0.99) and were linear over a range from 0.0005 mg/mL to 0.015 mg/mL. The method was validated by analysis of six replicates with 0.08% relative standard deviation and method detection and quantification limits were 20 ng/mL and 50 ng/mL respectively. Further validation of method on real urine samples from two groups of children (Control population:< 10 years of age; 5M: 3F and ASD individuals: <10 years of age; All males) showed that detection was effective over a wide range of metabolite at levels as high as 149.73 μg/mL to as low as 0.897 μg/mL. This study reports a rapid, validated and sensitive method for the detection of p-cresol in urine samples.
Gut microbiota has been implicated in many disorders including Autism Spectrum Disorder (ASD). ASD is a neurodevelopmental brain disorder affecting individuals leading to restricted and repetitive pattern of behaviour and disruption of communication and social interactions. Altered microbiome and the presence or absence of key species capable of affecting specific responses in levels of their fermentation products are reflected in the urinary metabolite profile of patients. The aim of our study is to develop an improvised method for the detection and quantification of urinary p-cresol levels which could serve as an indicator for GI microbial dysbiosis. The p-cresol analysis was achieved using HPLC by a reverse phase C18 column with mobile phase composition of Acetonitrile/water/formic acid (10:90:0.05, v/v/v) in an isocratic mode of elution with a flow rate of 1.0 mL/min. The mass analysis of p-cresol was performed using LC-MS [Triple Quadrupole Liquid Chromatography Mass Spectrometer] in negative ESI mode with electron multiplier detector. p-cresol was eluted at a retention time of approximately 3.4 min. The standard calibration curves had a superior regression coefficient of greater than 0.99 (R2 > 0.99) and were linear over a range from 0.0005 mg/mL to 0.015 mg/mL. The method was validated by analysis of six replicates with 0.08% relative standard deviation and method detection and quantification limits were 20 ng/mL and 50 ng/mL respectively. Further validation of method on real urine samples from two groups of children (Control population:< 10 years of age; 5M: 3F and ASD individuals: <10 years of age; All males) showed that detection was effective over a wide range of metabolite at levels as high as 149.73 μg/mL to as low as 0.897 μg/mL. This study reports a rapid, validated and sensitive method for the detection of p-cresol in urine samples.
Interest toward the human microbiome – the diverse and niche-specialized microbial communities that develop in the human host, particularly, the gut microbiome has increased in the recent past and their role in disease aetiologies have gained attention. The interactions between gut microbiota and the host have helped in understanding their roles and their unique metabolites and their implications in metabolism, development and homeostasis of immunity and the nervous system. Perturbation to the composition and function of the gut microbiota (gut microbial dysbiosis) may lead to dysfunction of host systems, thereby contributing to pathogenesis and/or progression toward a broad spectrum of conditions like inflammatory bowel disease, celiac disease, colorectal cancer, obesity, diabetes and Autism Spectrum Disorder (ASD) [1, 2, 3, 4, 5]. ASD is a collection of various neurodevelopmental disorders which comprises Autism Disorder (AD), Asperger syndrome (AS) and Pervasive developmental disorder (PDD) that begins early in the childhood [6]. Disturbances in multiple human systems including gastrointestinal disturbances are reported in the multifactorial manifestations of ASD symptoms [7].The human gut is inhabited by a complex and metabolically active microbial ecosystem which contributes to the intestinal metabolites of hosts, thus influencing the metabolome. Intestinal metabolites are shown to affect various physiological processes, including energy metabolism, cell-to-cell communication, and host immunity [8]. Altered GI microbiota and the alteration in levels of their fermentation products based on the presence and absence of key microbes needs attention. Gut dysbiosis and difference in the metabolite profiles are likely to be reflected in the bio fluids like urine. Detection and measurement of gut metabolites in urine and other bio fluids becomes critical.One such metabolite is p-cresol (C7H8O: 4 - methylphenol), an organic aromatic compound with a molecular weight of 108 kDa, which is produced by the gut microbes and has been implicated in neurological conditions like Autism Spectrum Disorder (ASD). It is hypothesized that p-cresol may contribute to worsen autism severity and gut dysfunction, often present in autistic children [2]. p-cresol is one of the metabolites of the amino acid tyrosine, and to a certain extent also of phenylalanine, which is converted to 4-hydroxyphenylacetic acid by intestinal bacteria, before being decarboxylated to p-cresol (putrefaction) [9]. The synthesis of p-cresol can happen in two distinct pathways in the gut microbiome. Clostridium difficle which is an anaerobic spore-forming bacteria expresses an enzyme namely p-hydroxy phenyl acetate decarboxylase which causes conversion of tyrosine to p-cresol [2]. Also, Pseudomonas stutzeri, Pseudomonas mendocina etc. produces p-cresol from toluene by toluene monooxygenase [3, 4]. The former pathway is significantly more important compared to the latter due to the increased availability of L-tyrosine when compared to toluene. p-cresol is metabolized through conjugation [10, 11] removal of the unconjugated p-cresol is, at least in part, via the urine [12]. Zeng et. al., (2017), have reported the detection of p-cresol levels and other metabolites in rat serum and urine [13].However according to recent studies, the frequency of GI tract symptoms and affected mechanisms in children with ASD has attracted attention [14, 15, 16, 17, 18, 19] and ranges from 9% - 84%. A number of studies in a subgroup of ASDpatients have documented the overgrowth of an unusual microflora population namely the Clostridium species. A study by Altieri et. al., (2011), observed an elevated level of p-cresol metabolite in urine samples of young children with ASD compared with control [20]. They also reported a positive correlation between p-cresol and ASD severity. p-cresol has stimulated interest as a biomarker with a potential to contribute to a multi-biomarker diagnostic panel for ASD [2]. Hence, urinary p-cresol as a metabolite, is important for conditions like ASD and its detection and evaluation merits attention.In this communication, we propose an effective method for urinary p-cresol detection and measurement with validation for urinary levels of p-cresol using control (<10 years of age; 5 Males: 3 Females) and ASD samples (<10 years of age; All males) from representative Indian population.
Materials and methods
Chemicals and reagents
Standard GI metabolite p-cresol was procured from Sigma-Aldrich. Milli-Q water (MQW) was used for the preparation of all the solutions. All HPLC grade of Acetonitrile, Methanol, Trifluoroacetic acid, Diethylether were purchased from Sisco Research Laboratories Pvt. Ltd. India. Analytical grade Formic acid was procured from Sisco Research Laboratories Pvt. Ltd. India. Sodium hydroxide was obtained from Merck Specialities Private Limited, India.
Collection of urine samples from ASD and control population
Early morning urine samples were collected from neuro-typical, high functioning, normal, faculty children at BITS, Pilani-Hyderabad campus after getting a signed informed consent from the parent of the children. This acted as the normal control population for the study. Similarly, patient samples were collected from the “Autism Ashram” Center at Keshavaram, Hyderabad, India. In both controls and ASDchildren, early morning urine sample was taken for analysis. The ASDchildren were on vegetarian Jain food diet (no onion, garlic and less spice simple nutritious food) on a regular basis. The control children had normal Indian diet. Sample size of four children diagnosed with ASD (<10 years of age; All males) and 8 controls (<10 years of age; 5 Males: 3 Females) each were considered and their urine samples were used for validation of the developed method. Labelled vials were provided for the urine sample collection. A sample amount of 10–15 mL was collected and reproducibility of the results was also confirmed. Proper care was taken to follow all ethical and standard guidelines for the collection and storage of urine samples. The study was approved by the Institutional Human Ethics Committee (BITS-HYD/IHEC/2019/01). The collected urine samples were stored at -20 °C in order to minimize the variations arising during the collection.
Sample preparation for the determination of urinary p-cresol levels in normal and ASD individuals
The samples were taken from -20 °C and thawed for further sample processing. To 1.0 mL of the urine sample in the glass vials, 400 μL of concentrated hydrochloric acid was added. The above mixture was boiled at 90 °C for 60 min [21]. The mixture was cooled down and the phenols were extracted with 800μL of diethylether. It was mixed by repeated inversions in glass vials for 1 min. This was then centrifuged at 500 g for 10 min (Eppendorf centrifuge 5430R). After the clear distinction of the aqueous and organic phase, the organic phase was transferred into 2 mL amber glass HPLC vials. Later the organic phase was aspirated into 600 μL of 0.05M NaOH in methanol. The resultant solution was evaporated to dryness under vacuum condition at 45 °C. The residue was dissolved in 1 mL MilliQ water, filtered by syringe filter (PVDF syringe filter 13mm, 0.45 μm, Axiva) and analysed to HPLC system for p-cresol determination.
Instrumentation
The p-cresol was measured by High performance liquid Chromatography (HPLC) connected with Photo Diode Array (PDA) detection. C18, 5μm particle size (Sigma, Ascentis, ODS, 150 × 4.6mm) column was used in HPLC Shimadzu Corporation system (MODEL NO. CTO-10ASVP). The column temperature was maintained at 28 °C with a UV detection wavelength of 270nm. The mobile phase acetonitrile/water/formic acid (10:90:0.05, v/v/v) was prepared. The mobile phase was filtered through 0.22μm membrane filter and sonicated to remove air bubbles. The HPLC was performed under isocratic mode of elution with a flow rate of 1.0 mL/min. The mass analysis of the standard was performed using LC-MS [LCMS-8040, Triple Quadrupole Liquid Chromatography Mass Spectrometer, SHIMADZU Corporation] in ESI mode. The liquid chromatograph had an inbuilt on-line degasser, UFLCXR autosampler, a binary gradient elution pumping system and an electron multiplier detector. All parameters were controlled by LabSolutions LCMS software, version 5.4 (SHIMADZU Corporation).
Preparation of standard solutions
The stock standard solution of p-cresol was prepared at a concentration of 1.0 mg/mL using acetonitrile/water (5:95, v/v) and stored at 4 °C. Further working standard solution of 0.0005 mg/mL, 0.001 mg/mL, 0.005 mg/mL, 0.01 mg/mL, 0.015 mg/mL were prepared from stock standard solution using acetonitrile/water (5:95, v/v). The standard solution was filtered using 0.45μm syringe filter and filled in amber vials for HPLC analysis. 30 μL of each linearity standard solution was injected into HPLC. These working standard solutions were used to check the detection of the compound at various concentration by HPLC and also to determine the linearity range of compound from the regression coefficient value in standard calibration plot. The standard calibration curve was developed by plotting the peak areas of p-cresol against the set of concentration used for standard preparation.
Results and discussion
Method development and standardization for the detection of p-cresol levels using HPLC
Different concentration of p-cresol analysis was performed using a C18 column, 5μm particle size (Sigma, Ascentis, ODS, 150 × 4.6mm) in HPLC Shimadzu Corporation system. PDA detection for p-cresol was done at wavelength 270nm. The retention time was approximately 3.4 min (Figure 1). The standard calibration curve was developed by plotting the peak areas of p-cresol against the set of concentration used for standard preparation, to obtain a standard curve equation y = mx + c with a regression value of R2 = 0.999 (Figures 2 and 3). Here, ‘y’ corresponds to the peak area and ‘x’ corresponds to the set of concentrations used for standard development. Table 1 shows the concentration of p-cresol versus the peak area using HPLC with PDA detection at 270 nm. The method was successfully used for the detection of p-cresol at various concentrations using HPLC. The LOD (Limit of detection) and LOQ (limit of Quantification) of p-cresol was found to be 20 ng/mL and 50 ng/mL respectively.
Figure 1
Comparison of p-cresol standards at different concentrations.
Figure 2
Linearity standard calibration curve of p-cresol.
Figure 3
A- Blank; B-F- p-cresol standards at 0.0005 mg/mL, 0.001 mg/mL, 0.005 mg/mL, 0.01 mg/mL, 0.015 mg/mL concentration respectively with PDA detection at 270 nm (PDA Multi 270 nm,4 nm) with a retention time of approximately 3.4 min.
Table 1
Evaluation of concentration versus peak area using HPLC for the p-cresol standards in improvised method.
S.NO
Concentration (mg/mL)
Peak area
Retention time (mins)
1
0.0005
14845
3.397
2
0.001
17087
3.369
3
0.005
79531
3.368
4
0.010
159350
3.366
5
0.015
242172
3.368
Comparison of p-cresol standards at different concentrations.Linearity standard calibration curve of p-cresol.A- Blank; B-F- p-cresol standards at 0.0005 mg/mL, 0.001 mg/mL, 0.005 mg/mL, 0.01 mg/mL, 0.015 mg/mL concentration respectively with PDA detection at 270 nm (PDA Multi 270 nm,4 nm) with a retention time of approximately 3.4 min.Evaluation of concentration versus peak area using HPLC for the p-cresol standards in improvised method.Limit of detection (LOD-3σ) was calculated as three times the standard deviation of the lowest concentration by the slope (m) of the calibration curve. Limit of quantification (LOQ-10σ) was determined as 10 times the standard deviation of the lowest concentration by the slope (m) of the calibration curve.
Mass spectrometry of standard p-cresol
Standard p-cresol was analysed using Mass spectrometry in ESI (Electron Spray Ionization) mode with Electron multiplier detector. The analysis in mass spectrometry is usually done in both positive as well as the negative mode of ESI ionization where the ionic form of the compound that is either protonated [M-H]+ or deprotonated form [M-H]- is obtained [13]. The organic compound p-cresol (m/z = 108) [22] is deprotonated and is obtained in the negative mode of ESI with an m/z ratio of 107 (C7H7O) (Figure 4). This acted as the reference for the detection of p-cresol in urine samples.
Figure 4
LC-MS fragmentation pattern of p-cresol with major m/z of 107.
LC-MS fragmentation pattern of p-cresol with major m/z of 107.
Validation of the method for urinary p-cresol detection in normal and ASD individuals
After the successful optimization of the proposed method, the same set of HPLC parameters as that of the standard was followed for real urine samples. Biological fluid such as urine was used to check the validation of p-cresol detection due to its complexity caused by the interference of other metabolites. The processed urine samples of both normal and autistic population were analysed by HPLC system for detection of p-cresol. It was confirmed that p-cresol is present in the urine sample based on the retention time of the standard. It was further validated by LC-MS analysis which confirmed the presence of p-cresol based on reference standards. Hence after the completion of analysis, the peak area, for both normal and ASD samples, was integrated (Figure 5 and 6). Table 2 depicts the concentration of urinary p-cresol obtained in normal and autistic individuals from the Indian population.
Figure 5
p-cresol detection (PDA Multi 1 270 nm,4 nm) and quantification in normal control urine sample with a retention time of approximately 3.4 min. (C1 to C8 are control urine samples from children of the age group between 3-9).
Figure 6
p-cresol detection (PDA Multi 1 270 nm,4 nm) and quantification in Autistic urine samples with a retention time of approximately 3.4 min. (A1-A4 are urine samples of children with ASD from the age group between 8-9).
Table 2
Urinary p-cresol peak area and concentration in normal and autistic individuals.
Nature of the sample
Sample identifier
Age/Sex
Peak area
p-cresol concentration (μg/mL)
Control
C1
7 years, Female
17586
0.897
C2
3 years, Female
56256
2.812
C3
9 years, Female
26007
1.300
C4
5 years, Male
32390
1.620
C5
9 years, Male
85520
4.270
C6
7 years, Male
29762
1.488
C7
8 years, Male
47967
2.390
C8
9 years, Male
123040
6.152
Children with ASD
A1
8 years, Male
60232
3.011
A2
9 years, Male
71663
35.830
A3
9 years, Male
299469
149.730
A4
9 years, Male
89305
4.460
p-cresol detection (PDA Multi 1 270 nm,4 nm) and quantification in normal control urine sample with a retention time of approximately 3.4 min. (C1 to C8 are control urine samples from children of the age group between 3-9).p-cresol detection (PDA Multi 1 270 nm,4 nm) and quantification in Autistic urine samples with a retention time of approximately 3.4 min. (A1-A4 are urine samples of children with ASD from the age group between 8-9).Urinary p-cresol peak area and concentration in normal and autistic individuals.
Mass spectrometry of urinary p-cresol
Urine samples were analysed by Mass spectrometry in ESI (Electron Spray Ionization) mode with electron multiplier detector to detect the presence of urinary p-cresol. p-cresol is obtained in the negative mode of ESI with an m/z ratio of 107 as that of the standard (Figure 7). This confirms the presence of p-cresol in both normal control population as well as the autistic population.
Figure 7
LC-MS fragmentation pattern of p-cresol in autistic urine sample.
LC-MS fragmentation pattern of p-cresol in autistic urine sample.Based on the results obtained, the proposed method was successfully able to detect and quantify urinary p-cresol levels in human urine samples. The efficiency of the method was validated by evaluating the levels of urinary p-cresol between ASD and control population in India. As the range of detection was broad, it was able to distinguish urinary p-cresol levels as high as 149.73 μg/mL to as low as 0.897 μg/mL. Elevated levels of urinary p-cresol as seen in patient 2 and 3 were in accordance with previously published report [16]. The method was further validated by using validation parameters such as Linearity, LOD, LOQ etc.
Validation parameters for the proposed method
The ICH (International Council for Harmonisation) guidelines recommend evaluating a minimum of five concentrations in order to determine the linearity range. Calibration plots were constructed for five different concentrations of p-cresol and it was linear over a range from 0.5 mg/L to 15 mg/L with a regression coefficient of always R2>0.99. The repeatability of the proposed method was ascertained by injecting six replicates of known sample concentration and determining the variations in peak area, retention time and peak height in percentage Relative Standard deviation (%RSD). To ensure the precision of the method, %RSD should be < 2. The precision of the proposed method was always less than %RSD <0.5. Limit of detection is defined as the lowest concentration of the analyte which can be detected but not necessarily quantified. It was determined to be 20 ng/mL. Limit of Quantification is defined as the lowest amount of the analyte which can be quantified with accuracy and precision. It was determined to be 50 ng/mL. Systems suitability parameters are the most integral part of any given analytical procedure. The ideology is that the analytical operations, equipment and sample play a crucial role in the system. The primary SST parameters are % RSD, Plate count (N), Tailing factor (TF). The acceptable range for each parameter is shown in Table 3. All the SST parameters for the proposed method were found within range of guidelines from FDA's Center for Drug Evaluation and Research (CDER) [13].
Table 3
System Suitability Test parameters for the improved method.
System Suitability Test parameters for the improved method.
Comparison with previously reported methods
The proposed method was compared with previous reports and the comparative parameters are listed in Table 4. The method developed uses a unique combination of solvent i.e. Acetonitrile, water and formic acid, not reported earlier in any study. In the isocratic mode, earlier methods developed by, Birkett et. al. (1995) [21], Schlatter et al. (1995) [23], Yoshikawa et. al. (1986) [24] had run times of 40, 20 and 16 min respectively while the proposed method had a greater efficiency with a run time of 10 min only. An earlier report from Lee et. al. (2009) [25] in the binary gradient mode had a low run time of 5 min, however, the LOD/LOQ outcomes of the developed method in this study were better. Comparative analysis of LOD/LOQ across previously reported methods in Isocratic/Binary gradient modes, clearly indicate the proposed method to be superior.
Table 4
Comparison of the improvised method with other reported method.
S.No
Compound
Sample Type
Mobile phase composition
Run time (min)
LOD, LOQ
Mode of elution
Ref
1
p-cresol
Human urine
ACN/H2O/Formic acid
10
20 ng/mL, 50 ng/mL
Isocratic
Present work
2
p-cresol
Human urine
ACN/H2O/TFA
25
20 ng/mL, 70 ng/mL
Binary gradient
[20]
5
p-cresol
Urine/faeces
Methanol/Phosphate buffer
40
0.8 μg/mL, N.A*
Isocratic
[21]
3
p-cresol
Human Urine
ACN/H2O/Phosphoric acid
20
0.2 μg/mL, N.A*
Isocratic
[23]
4
p-cresol
Human urine
ACN/H2O/β-cyclodextrin
16
15 ng/mL, N.A*
Isocratic
[24]
6
p-cresol
Human urine
Ethanol/acetic acid/β-cyclodextrin
5
0.8 μg/ml, N.A*
Binary gradient
[25]
Comparison of the improvised method with other reported method.
Conclusions
This study reports a rapid, validated and sensitive method for the detection of p-cresol. The efficiency of the method was validated by detection and quantification of urinary p-cresol levels between normal and autistic individuals. With six replicates, using acetonitrile (ACN), water, formic acid as eluents under isocratic mode, the LOD and LOQ were found to be 20 ng/mL and 50 ng/mL respectively. Urine being a complex biological fluid, the addition of internal standard and performing the validation on fortified urine would have helped judge the precision of the method better. Definitive conclusions cannot be arrived for levels of p-cresol between control and ASD samples, due to the smaller number of samples analysed in the Indian population and the intent was only for the validation of the developed method. Direct outcomes on p-cresol levels between controls and ASDpatients need more follow up studies and remains inconclusive.
Declarations
Author contribution statement
Vidya Rajesh: Conceived and designed the experiments; Contributed reagents, materials, analysis tools or data; Wrote the paper.E Nandini: Performed the experiments; Wrote the paper.B Arunraj: Analyzed and interpreted the data; Wrote the paper.N Rajesh: Conceived and designed the experiments; Wrote the paper.
Funding statement
This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Competing interest statement
The authors declare no conflict of interest.
Additional information
No additional information is available for this paper.
Authors: Susan E Levy; Margaret C Souders; Richard F Ittenbach; Ellen Giarelli; Andrew E Mulberg; Jennifer A Pinto-Martin Journal: Biol Psychiatry Date: 2007-01-03 Impact factor: 13.382
Authors: Timothy Buie; Daniel B Campbell; George J Fuchs; Glenn T Furuta; Joseph Levy; Judy Vandewater; Agnes H Whitaker; Dan Atkins; Margaret L Bauman; Arthur L Beaudet; Edward G Carr; Michael D Gershon; Susan L Hyman; Pipop Jirapinyo; Harumi Jyonouchi; Koorosh Kooros; Rafail Kushak; Pat Levitt; Susan E Levy; Jeffery D Lewis; Katherine F Murray; Marvin R Natowicz; Aderbal Sabra; Barry K Wershil; Sharon C Weston; Lonnie Zeltzer; Harland Winter Journal: Pediatrics Date: 2010-01 Impact factor: 7.124