Literature DB >> 3186384

Pediatric defibrillation: importance of paddle size in determining transthoracic impedance.

D L Atkins1, S Sirna, R Kieso, F Charbonnier, R E Kerber.   

Abstract

Transthoracic impedance is a major determinant of successful defibrillation or cardioversion, but no data are available concerning the range and determinants of transthoracic impedance in children. Transthoracic impedance was measured in ten ambulatory infants, 6 weeks to 9 months of age, and 37 children, 1.5 to 15 years of age, using a previously validated "test pulse" technique that measures transthoracic impedance without actually delivering a shock. We used hand-held "pediatric" (21 cm2) and "adult" (83 cm2) electrode paddles coated with either Redux paste or Redux creme. Transthoracic impedance in children was 108 +/- 24 omega (range 61 to 212 omega) using pediatric paddles. Using adult paddles lowered the transthoracic resistance by 47% to 57 +/- 11 omega (range 29 to 101 omega), P less than .05. In infants, transthoracic impedance (measured only with pediatric paddles) was 94 +/- 17 omega (range 74 to 124 omega). Using Redux paste as the coupling agent reduced transthoracic impedance by 13% (P less than .05). Transthoracic impedance was significantly but poorly related to body weight and body surface areas, but the correlations were not sufficiently high to be clinically useful. These data indicate that the larger adult electrode paddles will minimize transthoracic impedance and should be used when the child's thorax is large enough to permit electrode to chest contact over the entire paddle surface. This transition occurred at an approximate weight of 10 kg.

Entities:  

Mesh:

Year:  1988        PMID: 3186384

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  6 in total

1.  Part 10: Pediatric basic and advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations.

Authors:  Monica E Kleinman; Allan R de Caen; Leon Chameides; Dianne L Atkins; Robert A Berg; Marc D Berg; Farhan Bhanji; Dominique Biarent; Robert Bingham; Ashraf H Coovadia; Mary Fran Hazinski; Robert W Hickey; Vinay M Nadkarni; Amelia G Reis; Antonio Rodriguez-Nunez; James Tibballs; Arno L Zaritsky; David Zideman
Journal:  Circulation       Date:  2010-10-19       Impact factor: 29.690

2.  Pediatric basic and advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations.

Authors:  Monica E Kleinman; Allan R de Caen; Leon Chameides; Dianne L Atkins; Robert A Berg; Marc D Berg; Farhan Bhanji; Dominique Biarent; Robert Bingham; Ashraf H Coovadia; Mary Fran Hazinski; Robert W Hickey; Vinay M Nadkarni; Amelia G Reis; Antonio Rodriguez-Nunez; James Tibballs; Arno L Zaritsky; David Zideman
Journal:  Pediatrics       Date:  2010-10-18       Impact factor: 7.124

3.  Guidelines for paediatric life support. Paediatric Life Support Working Party of the European Resuscitation Council.

Authors: 
Journal:  BMJ       Date:  1994-05-21

4.  Elevated impedance during cardioversion in neonates with atrial flutter.

Authors:  Scott R Ceresnak; Thomas J Starc; Allan J Hordof; Robert H Pass; William J Bonney; Leonardo Liberman
Journal:  Pediatr Cardiol       Date:  2009-04-14       Impact factor: 1.655

5.  Defibrillation in children.

Authors:  Sarah E Haskell; Dianne L Atkins
Journal:  J Emerg Trauma Shock       Date:  2010-07

Review 6.  A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation.

Authors:  Yasmine Heyer; Daniela Baumgartner; Christian Baumgartner
Journal:  Sensors (Basel)       Date:  2022-04-06       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.