| Literature DB >> 31861817 |
Ulises Alvarado1,2, Anna Zamora1, Jinfang Liu1, Jordi Saldo1, Manuel Castillo1.
Abstract
The front-face fluorescence spectroscopy technique was used to establish a rapid prediction model of riboflavin concentration in milk without prior sample preparation. The prediction model developed was then compared with two conventional high performance liquid chromatography (HPLC)-based quantification methods. The method of standard addition allowed detecting a linear correlation between fluorescence intensity and riboflavin concentration in 12% (w/w) reconstituted low-heat milk powder. Validation of the model yielded an R2 of 0.99 with a standard error of prediction of 0.13 mg/L. The results suggest a potential use of front-face fluorescence spectroscopy as a simple method for off- and in-line determinations of riboflavin in milk.Entities:
Keywords: front-face fluorescence; milk; prediction; rapid quantification; riboflavin
Year: 2019 PMID: 31861817 PMCID: PMC7022819 DOI: 10.3390/foods9010006
Source DB: PubMed Journal: Foods ISSN: 2304-8158
Figure 1Fluorescence calibration curve at known concentrations of riboflavin in reconstituted skimmed milk powder. Three independent replications of each concentration are represented.
Figure 2Relationship between estimated concentration of riboflavin and reference values. Three independent replications of each concentration are represented.
Quantification of riboflavin in reconstituted commercial skimmed milk powder (SMP) and skimmed UHT milk (sUHT) by different methods.
| Methods | SMP-1 | SMP-2 | SMP-3 | sUHT-1 | sUHT-2 |
|---|---|---|---|---|---|
| Method 1 | 1.69 ± 0.05 a | 1.70 ± 0.03 a | 1.84 ± 0.01 a | 1.22 ± 0.01 a | 1.26 ± 0.01 a |
| Method 2 | 1.72 ± 0.01 a | 1.66 ± 0.02 a | 1.57 ± 0.03 b | 1.26 ± 0.01 a | 1.25 ± 0.05 a |
| Method 3 | 1.82 ± 0.12 a | 1.62 ± 0.11 a | 1.54 ± 0.11 b | 1.30 ± 0.20 a | 1.30 ± 0.20 a |
Mean value ± standard deviation (SD) (mg/L). a, b Values per column without common superscripts were significantly different (p < 0.05); n = 9. SMP: skimmed milk powder; sUHT: skimmed ultra-high temperature milk. Method 1: Front-face fluorescence; Method 2: HPLC at UAB; Method 3: HPLC by certified external laboratory.
Quantification of riboflavin in commercial whole UHT milks (wUHT) by different methods.
| Methods | wUHT-1 | wUHT-2 |
|---|---|---|
| Method 1a | 1.79 ± 0.06 a | 1.87 ± 0.10 a |
| Method 1b | 1.31 ± 0.03 b | 1.35 ± 0.06 b |
| Method 2 | 1.29 ± 0.04 b | 1.24 ± 0.06 b |
| Method 3 | 1.40 ± 0.20 b | 1.30 ± 0.20 b |
Mean value ± SD (mg/L). a, b Values per column without common superscripts were significantly different (p < 0.05); n = 12. wUHT: whole ultra-high temperature. Method 1a: direct front-face fluorescence (FFF); Method 1b: centrifugation and FFF; Method 2: HPLC at UAB; Method 3: HPLC by certified external laboratory.