Fracture loads of screw-retained implant-supported zirconia prostheses after thermal and mechanical stress.

Junichi Honda1, Futoshi Komine2, Kosuke Kusaba1, Jin Kitani1, Keisuke Matsushima1, Hideo Matsumura1.   

Abstract

PURPOSE: The objective of the present study was to evaluate fracture loads of screw-retained implant-supported zirconia prostheses after artificial aging.
METHODS: Four types of screw-retained implant-supported prostheses were fabricated (n=11 each); porcelain-veneered zirconia prosthesis (PVZ), indirect composite-veneered zirconia prosthesis (IVZ), porcelain-fused-to-metal prosthesis (PFM), and monolithic zirconia prosthesis (ML). The specimens were subjected to 10,000 thermocycles and cyclic loading for 1.2 million cycles. Fracture loads were measured, and the data were analyzed with the Kruskal-Wallis and Steel-Dwass tests (α=0.05).
RESULTS: All specimens survived the artificial aging procedures. The fracture loads for the PVZ (1.52kN), IVZ (1.62kN), and PFM groups (1.53kN) did not significantly differ; however, the fracture load for the ML group (6.61kN) was significantly higher than those for the other groups. The fracture load for the IVZ group was comparable to those for the PVZ and PFM groups.
CONCLUSIONS: The monolithic zirconia prostheses exhibited significantly higher fracture loads than the bilayered prostheses. All the investigated types of screw-retained implant-supported zirconia prostheses appear sufficient to resist posterior masticatory forces during long-term clinical use.
Copyright © 2019 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aging; Fracture load; Implant-supported prosthesis; Screw-retained; Zirconia

Mesh:

Substances:

Year:  2019        PMID: 31859081     DOI: 10.1016/j.jpor.2019.09.003

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  4 in total

1.  The effect of aging on the fracture resistance of different types of screw-cement-retained implant-supported zirconia-based restorations.

Authors:  Safoora Sahebi; Rashin Giti; Arian Sherafati
Journal:  PLoS One       Date:  2022-06-24       Impact factor: 3.752

2.  Fracture Resistance of CAD/CAM Implant-Supported 3Y-TZP-Zirconia Cantilevers: An In Vitro Study.

Authors:  Mariana Novais; António Sérgio Silva; Joana Mendes; Pedro Barreiros; Carlos Aroso; José Manuel Mendes
Journal:  Materials (Basel)       Date:  2022-09-24       Impact factor: 3.748

3.  Towards Clinical Translation: Optimized Fabrication of Controlled Nanostructures on Implant-Relevant Curved Zirconium Surfaces.

Authors:  Divya Chopra; Karan Gulati; Sašo Ivanovski
Journal:  Nanomaterials (Basel)       Date:  2021-03-29       Impact factor: 5.076

4.  Mechanical Stability of Screw-Retained Monolithic and Bi-layer Posterior Hybrid Abutment Crowns after Thermomechanical Loading: An In Vitro Study.

Authors:  Frank A Spitznagel; Estevam A Bonfante; Tiago M B Campos; Maximilian A Vollmer; Johannes Boldt; Sam Doerken; Petra C Gierthmuehlen
Journal:  Materials (Basel)       Date:  2021-12-08       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.