Literature DB >> 31856989

Kinetic visual acuity, stereopsis, and ocular deviation with an implantable collamer lens.

Sayaka Kato1, Kimiya Shimizu2, Akihito Igarashi2, Takushi Kawamorita3.   

Abstract

PURPOSE: To compare kinetic visual acuity, stereopsis, ocular deviation, and fusion amplitude before and after implantable collamer lens (ICL) surgery.
SETTING: Sanno Hospital.
DESIGN: Retrospective analysis.
METHODS: The charts of adult patients who underwent implantation of an ICL with a central aquaport (V4c) for emmetropia were reviewed. The mean preoperative spherical equivalent and subjective astigmatism were -7.87 diopters (D) ± 3.13 (SD) and -0.75 ± 0.78 D, respectively. All measurements were obtained with full refraction before surgery and without spectacle correction after surgery. The kinetic visual acuity was measured with the AS-4D device. Stereopsis and ocular deviation were measured with the Titmus Stereotest and an alternate prism cover test, respectively. Fusion amplitude was determined from breakpoints measured using a prism.
RESULTS: The study comprised 29 adult patients (58 eyes). One month postoperatively, the mean safety and efficacy indices were 1.13 ± 0.20 and 0.96 ± 0.25, respectively, and 57 eyes (98.7%) were within ±0.5 D of the target correction. The mean kinetic visual acuity (logarithm of the minimum angle of resolution) was 0.30 ± 0.21 preoperatively and 0.20 ± 0.15 (Snellen 20/40 versus 20/32) postoperatively and the mean stereopsis (seconds of arc), 48.5 ± 1.6 versus 41.5 ± 1.1; both improved significantly (P < .001 and P = .012, respectively). The mean distance ocular deviation (-4.0 ± 3.8 prism diopters [Δ] versus 2.8 ± 3.6 Δ; P = .002) and near ocular deviation (-6.5 ± 6.7 Δ versus 5.4 ± 6.9 Δ; P = .04) decreased significantly. The fusion amplitude increased for near vision only.
CONCLUSIONS: ICL implantation improved kinetic visual acuity and stereopsis, decreased ocular deviation, and increased near fusion amplitude.
Copyright © 2019 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2019        PMID: 31856989     DOI: 10.1016/j.jcrs.2019.08.009

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  2 in total

1.  Changes in Accommodative and Binocular Function following Phakic Intraocular Lens for High and Low-to-Moderate Myopia.

Authors:  Esther López-Artero; Francisco Poyales; Nuria Garzón; Alicia Matamoros; Alba Sáez; Ying Zhou; María García-Montero
Journal:  Int J Environ Res Public Health       Date:  2022-05-31       Impact factor: 4.614

2.  Effect of Photochromic Contact Lens Wear on Indoor Visual Performance and Patient Satisfaction.

Authors:  Kazutaka Kamiya; Shuya Suzuki; Fusako Fujimura
Journal:  Ophthalmol Ther       Date:  2022-07-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.