Literature DB >> 31855596

Reduction of Occupational Exposure Using a Novel Tungsten-Containing Rubber Shield in Interventional Radiology.

Kenta Kijima1, Anchali Krisanachinda2, Mikoto Tamura1, Hajime Monzen1, Yasumasa Nishimura3.   

Abstract

This study investigates whether a novel tungsten-containing rubber shield could be used as substitute shielding material in interventional radiology to reduce the occupational exposure of operators to scattered radiation from a patient. The tungsten-containing rubber is a lead-free radiation-shielding material that contains as much as 90% tungsten powder by weight. Air kerma rates of scattered radiation from solid-plate phantoms, simulating a patient, were measured with a semiconductor dosimeter at the height of the operator's eye (1,600 mm from the floor), chest (1,300 mm), waist (1,000 mm), and knee (600 mm) with and without tungsten-containing rubber shielding (1-5 mm thickness). The tungsten-containing rubber and a commercial shielding material (RADPAD) were affixed onto the phantom on the operator's side, and reductions in air kerma rates were compared. Reduction rates for tungsten-containing rubber shielding with thicknesses of 1, 2, 3, 4, and 5 mm at each height level were as follows: 70.37 ± 0.40%, 72.17 ± 0.29%, 72.95 ± 0.31%, 72.58 ± 0.35%, and 73.63 ± 0.63% at eye level; 76.36 ± 0.19%, 77.13 ± 0.10%, 77.36 ± 0.14%, 77.62 ± 0.25%, and 77.66 ± 0.14% at chest level; 67.78 ± 0.31%, 68.12 ± 0.19%, 68.88 ± 0.28%, 68.97 ± 0.14%, and 68.85 ± 0.45% at waist level; and 0.14 ± 0.94%, 0.72 ± 0.56%, 1.08 ± 0.74%, 1.77 ± 0.80%, and 1.79 ± 1.82% at knee level, respectively. Reduction rates with RADPAD were 61.80 ± 0.67%, 60.33 ± 0.61%, 64.70 ± 0.25%, and 0.14 ± 0.66% at eye, chest, waist, and knee levels, respectively. The shielding ability of the 1 mm tungsten-containing rubber was superior to that of RADPAD. The tungsten-containing rubber could be employed to minimize an operator's radiation exposure instead of the commercial shielding material in interventional radiology.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 31855596     DOI: 10.1097/HP.0000000000001177

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  2 in total

1.  Dosimetric characteristics of a thin bolus made of variable shape tungsten rubber for photon radiotherapy.

Authors:  Katsuya Okuhata; Mikoto Tamura; Hajime Monzen; Yasumasa Nishimura
Journal:  Phys Eng Sci Med       Date:  2021-09-20

2.  Estimating radiation exposure of the brain of a physician with a protective flap in interventional radiology: A phantom study.

Authors:  Shota Hattori; Hajime Monzen; Mikoto Tamura; Hiroyuki Kosaka; Yasunori Nakamura; Yasumasa Nishimura
Journal:  J Appl Clin Med Phys       Date:  2022-01-19       Impact factor: 2.102