Background. Surgical stapling devices are known for their reliability and convenience. A letter to health care professionals published by the US Food and Drug Administration in March 2019 highlighted the increasing number of adverse events associated with surgical staplers. Driven by a case of stapler malfunction during an elective laparoscopic sleeve gastrectomy, we performed a literature review to investigate the incidence of primary stapler malfunction. We also discuss the common types and an approach to its management. Methods. PubMed, MEDLINE, and EMBASE databases were searched for articles discussing surgical stapler malfunction. Twelve studies were selected that described the incidence and/or consequences of primary stapler malfunction. A narrative synthesis was performed. Results. From observational studies, the incidence ranged from 0.022% to 2.3%. A prospective survey reported that 86% of laparoscopic surgeons either had personal experience with or knew of surgeons who experienced stapler malfunction, implying a higher incidence. Underreporting has been an issue as manufacturers can get exemptions from public reporting. Significantly, higher malfunctions have been reported after exemptions were lifted. The most common types of stapler malfunction are stapler misfire and stapler locking. Major morbidity and mortality have been reported. Conclusion. Surgeons are increasingly reliant on technological innovations. Stapling failure occurs and it is imperative to be aware of this. Given the high volume of stapler use, a high percentage of surgeons are likely to encounter this problem in their career. It is important to have an approach to the prevention and management of this potentially catastrophic complication.

Keywords:  biomedical engineering; colorectal surgery; gastric surgery

Year:  2019        PMID: 31854232     DOI: 10.1177/1553350619889274

Source DB:  PubMed          Journal:  Surg Innov        ISSN: 1553-3506            Impact factor:   2.058


  3 in total

1.  Stapled fascial suture: ex vivo modeling and clinical implications.

Authors:  Enrico Lauro; Ilaria Corridori; Lorenzo Luciani; Alberto Di Leo; Alberto Sartori; Jacopo Andreuccetti; Diletta Trojan; Giovanni Scudo; Antonella Motta; Nicola M Pugno
Journal:  Surg Endosc       Date:  2022-05-16       Impact factor: 4.584

2.  Continuously sutured versus linear-stapled anastomosis in robot-assisted hybrid Ivor Lewis esophageal surgery following neoadjuvant chemoradiotherapy: a single-center cohort study.

Authors:  Fiorenzo V Angehrn; Kerstin J Neuschütz; Daniel C Steinemann; Martin Bolli; Lana Fourie; Pauline Becker; Markus von Flüe
Journal:  Surg Endosc       Date:  2022-07-19       Impact factor: 3.453

3.  Stapler Malfunctions in Bariatric Surgery: An Analysis of the MAUDE Database.

Authors:  Benjamin Clapp; Alexander Schrodt; Maria Ahmad; Ellen Wicker; Nishtha Sharma; Andres Vivar; Brian Davis
Journal:  JSLS       Date:  2022 Jan-Mar       Impact factor: 1.789

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.