Literature DB >> 31853527

A self-contained and fully integrated fluidic cassette system for multiplex nucleic acid detection of bacteriuria.

Nan Li1, Ying Lu2, Jing Cheng3, Youchun Xu2.   

Abstract

The gold standard for diagnosing infectious diseases is culture-based identification of bacterial pathogens, which is time-consuming and labour-intensive. Current advances in molecular diagnostics and microfluidic technologies have made the rapid detection of bacteria or viruses in clinical specimens possible. However, the need for rapid, sensitive and multiplex detection of pathogens in a "sample-in and answer-out" manner has not been fully satisfied. In this study, a self-contained and fully integrated fluidic cassette and its supporting analyser were constructed for multiplex detection of bacteria to accelerate the diagnosis of urinary tract infections (UTIs). The fully integrated cassette contains all the necessary components and reagents for bacterial analysis. All of the bacterial analysis processes, including bacterial lysis, magnetic silica bead-based DNA extraction, DNA elution and multiplex loop-mediated amplification (LAMP), are automatically conducted in the cassette. This cassette was successfully applied for the detection of four major pathogenic bacteria in UTIs, i.e., Escherichia coli, Proteus mirabilis, Salmonella typhimurium and Staphylococcus aureus. The first three were successfully detected with a limit of detection (LoD) of 1 colony-forming unit (CFU) μL-1 and the last was with a LoD of 10 CFU μL-1 in urine samples, demonstrating that the cassette has similar sensitivity compared to that of the manual protocol, which is lower than that required by UTIs. The turnaround time for this cassette-based sample-to-answer system was approximately 100 minutes, and the detection is sensitive, fully automated, and accurate, demonstrating the potential to be a useful diagnostic tool for UTIs.

Entities:  

Year:  2019        PMID: 31853527     DOI: 10.1039/c9lc00994a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  4 in total

1.  Microfluidics for the rapid detection of Staphylococcus aureus using antibody-coated microspheres.

Authors:  Bo Song; Junsheng Wang; Zhijun Yan; Zhijian Liu; Xinxiang Pan; Yingbo Zhang; Xiaojie Zhang
Journal:  Bioengineered       Date:  2020-12       Impact factor: 3.269

2.  Contrast between traditional and machine learning algorithms based on a urine culture predictive model: a multicenter retrospective study in patients with urinary calculi.

Authors:  Yuhui He; Panxin Peng; Wenwei Ying; Qinwei Wang; Yan Wang; Xiankui Liu; Wenhui Song; Yue Gao; Peizhe Li; Jie Wang; Weijie Zhu; Wenzhi Gao; Xiaofeng Zhou; Xuesong Li; Liqun Zhou
Journal:  Transl Androl Urol       Date:  2022-02

3.  A Continuous Microfluidic Concentrator for High-Sensitivity Detection of Bacteria in Water Sources.

Authors:  Seunghee Choo; Hyunjung Lim; Tae Eun Kim; Jion Park; Kyu Been Park; Chaewon Park; Chae Seung Lim; Jeonghun Nam
Journal:  Micromachines (Basel)       Date:  2022-07-10       Impact factor: 3.523

4.  Microfluidics for the rapid detection of Escherichia coli O157:H7 using antibody-coated microspheres.

Authors:  Bo Song; Jiayuan Yu; Yan Sun; Qiao Wang; Shengnan Xu; Yichen Jia; Shuying Lin; Yueying Zhang; Chen Wang; Yingbo Zhang; Xiaojie Zhang
Journal:  Bioengineered       Date:  2021-12       Impact factor: 3.269

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.