Literature DB >> 3185302

Capillary configuration and fiber shortening in muscles of the rat hindlimb: correlation between corrosion casts and stereological measurements.

O Mathieu-Costello1, R F Potter, C G Ellis, A C Groom.   

Abstract

It has been a matter of discussion whether the dramatic increase in capillary tortuosity visualized in shortened muscles by vascular cast represents in vivo situations. In this study, we combined vascular cast and stereological methods in the same samples, in order to obtain (1) measurements of sarcomere length in the same muscles from which corrosion casts were prepared, and (2) scanning electron micrographs of the three-dimensional arrangement of capillaries in the same muscles where capillary anisotrophy was estimated by morphometry. Various rat skeletal muscles (soleus, gastrocnemius, and gracilis) were examined at lengths ranging from full shortening to full extension. We found a very good correlation between capillary geometry in material prepared for vascular casts and in muscles perfusion-fixed in situ. All muscles, cast and noncast, showed the same progressive curvilinear decrease in capillary anisotropy with decreasing sarcomere length. Capillary tortuosity visualized by corrosion casts in shortened muscles is a consequence of fiber shortening, within physiological sarcomere lengths; it does not represent an artifact related to the casting procedure.

Entities:  

Mesh:

Year:  1988        PMID: 3185302     DOI: 10.1016/0026-2862(88)90037-4

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  11 in total

1.  Three-dimensional study of the capillary supply of skeletal muscle fibres using confocal microscopy.

Authors:  L Kubínová; J Janácek; S Ribaric; V Cebasek; I Erzen
Journal:  J Muscle Res Cell Motil       Date:  2001       Impact factor: 2.698

2.  Mapping 3-D functional capillary geometry in rat skeletal muscle in vivo.

Authors:  Graham M Fraser; Stephanie Milkovich; Daniel Goldman; Christopher G Ellis
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-12-02       Impact factor: 4.733

Review 3.  Twisted blood vessels: symptoms, etiology and biomechanical mechanisms.

Authors:  Hai-Chao Han
Journal:  J Vasc Res       Date:  2012-03-14       Impact factor: 1.934

4.  Quantitative model for predicting lymph formation and muscle compressibility in skeletal muscle during contraction and stretch.

Authors:  Laura Causey; Stephen C Cowin; Sheldon Weinbaum
Journal:  Proc Natl Acad Sci U S A       Date:  2012-05-21       Impact factor: 11.205

5.  Effects of elastin degradation and surrounding matrix support on artery stability.

Authors:  Avione Y Lee; Boyang Han; Shawn D Lamm; Cesar A Fierro; Hai-Chao Han
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-12-09       Impact factor: 4.733

Review 6.  Exercise training and peripheral arterial disease.

Authors:  Tara L Haas; Pamela G Lloyd; Hsiao-Tung Yang; Ronald L Terjung
Journal:  Compr Physiol       Date:  2012-10       Impact factor: 9.090

7.  Calcium depletion reduces the destruction of fibrosarcoma cells in the microvasculature of artificially perfused rat hearts.

Authors:  U Nannmark; B R Johansson; U Bagge
Journal:  Clin Exp Metastasis       Date:  1992-09       Impact factor: 5.150

8.  Comparison of generated parallel capillary arrays to three-dimensional reconstructed capillary networks in modeling oxygen transport in discrete microvascular volumes.

Authors:  Graham M Fraser; Daniel Goldman; Christopher G Ellis
Journal:  Microcirculation       Date:  2013-11       Impact factor: 2.628

Review 9.  Image-based modelling of skeletal muscle oxygenation.

Authors:  B Zeller-Plumhoff; T Roose; G F Clough; P Schneider
Journal:  J R Soc Interface       Date:  2017-02       Impact factor: 4.118

Review 10.  Vessel-on-a-chip models for studying microvascular physiology, transport, and function in vitro.

Authors:  Savannah R Moses; Jonathan J Adorno; Andre F Palmer; Jonathan W Song
Journal:  Am J Physiol Cell Physiol       Date:  2020-11-11       Impact factor: 4.249

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.