Literature DB >> 31851056

Point-of-care ultrasound in the neonatal ICU.

Laura E Miller1, Jason Z Stoller2,3, María V Fraga2,3.   

Abstract

PURPOSE OF REVIEW: Point-of-care ultrasound (POCUS) is an emerging clinical tool in the neonatal intensive care unit (NICU). Recent literature describing the use of POCUS for various applications in the NICU has garnered increased interest among neonatologists. RECENT
FINDINGS: Diagnostic applications for POCUS in the NICU include the evaluation and serial monitoring of common pulmonary diseases, hemodynamic instability, patent ductus arteriosus (PDA), persistent pulmonary hypertension of the newborn (PPHN), necrotizing enterocolitis (NEC), and intraventricular hemorrhage (IVH), among others. Procedural applications include vascular access, endotracheal intubation, lumbar puncture, and fluid drainage.
SUMMARY: Experience with POCUS in the NICU is growing. Current evidence supports the use of POCUS for a number of diagnostic and procedural applications. As use of this tool increases, there is an urgent need to develop formal training requirements specific to neonatology, as well as evidence-based guidelines to standardize use across centers.

Entities:  

Mesh:

Year:  2020        PMID: 31851056     DOI: 10.1097/MOP.0000000000000863

Source DB:  PubMed          Journal:  Curr Opin Pediatr        ISSN: 1040-8703            Impact factor:   2.856


  13 in total

1.  Diagnostic accuracy of ultrasound for localising peripherally inserted central catheter tips in infants in the neonatal intensive care unit: a systematic review and meta-analysis.

Authors:  Shauna C Doyle; Niamh M Bergin; Rena Young; Andrew England; Mark F McEntee
Journal:  Pediatr Radiol       Date:  2022-05-05

2.  Point-of-care ultrasound for neonatal central catheter positioning: impact on X-rays and line tip position accuracy.

Authors:  Serena Rossi; K Haran Jogeesvaran; Eugen Matu; Hammad Khan; Elisabetta Grande; Virginie Meau-Petit
Journal:  Eur J Pediatr       Date:  2022-02-12       Impact factor: 3.183

3.  Point-of-care ultrasound (POCUS) protocol for systematic assessment of the crashing neonate-expert consensus statement of the international crashing neonate working group.

Authors:  Yasser Elsayed; Muzafar Gani Abdul Wahab; Adel Mohamed; Nadya Ben Fadel; Shazia Bhombal; Nadya Yousef; María V Fraga; Jehier Afifi; Pradeep Suryawanshi; Abbas Hyderi; Anup Katheria; Martin Kluckow; Daniele De Luca; Yogen Singh
Journal:  Eur J Pediatr       Date:  2022-10-14       Impact factor: 3.860

Review 4.  Gastric Point-of-Care Ultrasound in Acutely and Critically Ill Children (POCUS-ped): A Scoping Review.

Authors:  Frederic V Valla; Lyvonne N Tume; Corinne Jotterand Chaparro; Philip Arnold; Walid Alrayashi; Claire Morice; Tomasz Nabialek; Aymeric Rouchaud; Eloise Cercueil; Lionel Bouvet
Journal:  Front Pediatr       Date:  2022-07-06       Impact factor: 3.569

Review 5.  Sonographic Evaluation of the Endotracheal Tube Position in the Neonatal Population: A Comprehensive Review and Meta-Analysis.

Authors:  Sabrina Congedi; Federica Savio; Maria Auciello; Sabrina Salvadori; Daniel Nardo; Luca Bonadies
Journal:  Front Pediatr       Date:  2022-06-02       Impact factor: 3.569

6.  Ultrasound Assessment of the Relevance of Liver, Spleen, and Kidney Dimensions with Body Parameters in Adolescents.

Authors:  Ying Huang; Yumei Zheng; Cuncheng Zhang; Shigen Zhong
Journal:  Comput Math Methods Med       Date:  2022-07-04       Impact factor: 2.809

7.  The evolution of cardiac point of care ultrasound for the neonatologist.

Authors:  Yogen Singh; Shazia Bhombal; Anup Katheria; Cecile Tissot; María V Fraga
Journal:  Eur J Pediatr       Date:  2021-06-14       Impact factor: 3.183

Review 8.  Modern pulmonary imaging of bronchopulmonary dysplasia.

Authors:  Nara S Higano; J Lauren Ruoss; Jason C Woods
Journal:  J Perinatol       Date:  2021-02-05       Impact factor: 2.521

Review 9.  Respiratory muscle function in the newborn: a narrative review.

Authors:  Theodore Dassios; Aggeliki Vervenioti; Gabriel Dimitriou
Journal:  Pediatr Res       Date:  2021-04-19       Impact factor: 3.953

Review 10.  "Playing it SAFE in the NICU" SAFE-R: a targeted diagnostic ultrasound protocol for the suddenly decompensating infant in the NICU.

Authors:  Nadya Yousef; Yogen Singh; Daniele De Luca
Journal:  Eur J Pediatr       Date:  2021-07-05       Impact factor: 3.183