Literature DB >> 31848516

[Effects of different methods on drying root canal by near-field microwave detection system].

J S Wang1, P Y Wang2, Y H Liang1,3.   

Abstract

OBJECTIVE: To set up near-field microwave detection system, to evaluate the accuracy of measuring water and to compare the effects of different methods on drying root canal.
METHODS: Known and quantitative distilled water in Eppendorf tube and root canal was detected by near-field microwave detection system which was set up first. The microwave reflection coefficient was recorded so as to evaluate the accuracy of the measuring water. 12 single-rooted mandibular premolar teeth with apical matureness and a curvature less than 10° were decoronated, leaving roots 14 mm in length. After instrumentation to F3, the root canals were air-dried and injected with 10 μL distilled water each. Then all the root canals were assigned to 4 groups (n=12) according to different methods on root canal drying. Near-field microwave detection system was used to detect the change of water after air-drying and root canal drying so as to evaluate the effects of different root canal drying methods: (1) negative control group, the canals were injected with 10 μL distilled water and no root canal drying method was performed; (2) paper points drying experimental group, four #60 paper points were used to blot-dry the middle and upper part of the canal, followed by #40 paper points blot-drying the apical area. The above step was repeated with the tip of paper point that appeared with no water under microscope as finished; (3) 95% (volume fraction) ethanol drying experimental group, after the distilled water was removed with paper points (similar to paper points experimental group), 10 μL 95% ethanol was injected into the canal and was left in place for 10 s, then paper points were used to dry the canal; (4) 70% (volume fraction) isopropyl alcohol drying experimental group, after the distilled water was removed with paper points (similar to paper points experimental group), 10 μL 70% isopropyl alcohol was injected into the canal and was left in place for 10 s, then paper points were used to dry the canal. The linear correlation analysis was used to test the accuracy of the measuring water by near-field microwave detection method and physical measurement. The Pearson correlation coefficient was calculated based on the data. The effects of different methods on drying root canal were analyzed by Chi square test.
RESULTS: The R2 for the microwave reflection coefficient and the physical measurement of the water in Eppendorf tube and root canal were 0.991 and 0.970. The microwave reflection coefficient in all the experimental groups showed significant difference (P<0.05). After drying with paper points, the residual water was the most, and the microwave reflection coefficient was the highest: 0.023. While after 70% isopropyl alcohol drying root canal, the residual water was the least with the microwave reflection coefficient 0.006, showing that the effect of drying was the best.
CONCLUSION: Near-field microwave detection system could detect the change of water in root canal. The effect of root canal drying by 70% isopropyl alcohol was superior to 95% ethanol and paper points.

Entities:  

Mesh:

Year:  2019        PMID: 31848516      PMCID: PMC7433590     

Source DB:  PubMed          Journal:  Beijing Da Xue Xue Bao Yi Xue Ban        ISSN: 1671-167X


  9 in total

1.  Dentin moisture conditions affect the adhesion of root canal sealers.

Authors:  Emre Nagas; M Ozgur Uyanik; Ayhan Eymirli; Zafer C Cehreli; Pekka K Vallittu; Lippo V J Lassila; Veli Durmaz
Journal:  J Endod       Date:  2011-11-13       Impact factor: 4.171

2.  Novel methodology to evaluate the effect of residual moisture on epoxy resin sealer/dentine interface: a pilot study.

Authors:  S G Gibby; Y Wong; J C Kulild; K B Williams; X Yao; M P Walker
Journal:  Int Endod J       Date:  2010-10-11       Impact factor: 5.264

3.  Continuing etching of an all-in-one adhesive in wet dentin tubules.

Authors:  Y Wang; P Spencer
Journal:  J Dent Res       Date:  2005-04       Impact factor: 6.116

4.  Influence of moisture on the apical seal of root canal fillings with five different types of sealer.

Authors:  Matthias Johannes Roggendorf; Johannes Ebert; Anselm Petschelt; Roland Frankenberger
Journal:  J Endod       Date:  2006-10-13       Impact factor: 4.171

5.  Critical evaluation of the push-out test for root canal filling materials.

Authors:  Epita S Pane; Joseph E A Palamara; Harold H Messer
Journal:  J Endod       Date:  2013-02-12       Impact factor: 4.171

6.  Sealer penetration and apical microleakage in smear-free dentin after a final rinse with either 70% isopropyl alcohol or Peridex.

Authors:  Gregory T Engel; Gary G Goodell; Scott B McClanahan
Journal:  J Endod       Date:  2005-08       Impact factor: 4.171

7.  The prognosis for endodontic treatment of obliterated root canals.

Authors:  A Akerblom; G Hasselgren
Journal:  J Endod       Date:  1988-11       Impact factor: 4.171

8.  Leakage and sealer penetration in smear-free dentin after a final rinse with 95% ethanol.

Authors:  Richard W Stevens; James M Strother; Scott B McClanahan
Journal:  J Endod       Date:  2006-06-06       Impact factor: 4.171

9.  Two modes of nanoleakage expression in single-step adhesives.

Authors:  F R Tay; D H Pashley; M Yoshiyama
Journal:  J Dent Res       Date:  2002-07       Impact factor: 6.116

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.