Literature DB >> 31847524

4DCT-based evaluation of lung tumour motion during the breathing cycle.

M Adamczyk1, M Konkol2, M Matecka-Nowak2, T Piotrowski1,3.   

Abstract

The aim of this work was to quantify the variability in pre-treatment lung tumor motion during a single breathing period for 55 non-small cell lung cancer (NSCLC) targets. The influence of breathing on the volume and position of lung tumor was examined by comparing the information about tumor from respiratory-correlated four-dimensional computed tomography (4DCT) and three-dimensional computed tomography (3DCT) obtained without respiratory monitoring. The impact of age, gender, lung volume changes and immobilization device on tumor respiratory motion was evaluated. Based on the performed analysis, the significant differences were found between tumor volumes on 3DCT and 4DCT, although the comparison of volumes between 4DCT bins showed no statistically significant dependency. The significant differences between tumor centre of mass coordinates in the cranial-caudal (CC) and anterior-posterior (AP) directions were found. According to the results of statistical testing, there was no impact of gender and immobilization device on detected tumor respiratory motion. The impact was found for patient's age, lung volume changes, tumor volume and its location in different lung segments. The dominant lung cancer motion was observed for smaller tumors (up to 20 cc) located in posterior, caudal segments. This effect was also associated with a large variation in the lung volume during one respiratory cycle, observed for older patients. The important finding of the study is connected with the description of different patterns of tumor motion in AP and CC directions.

Entities:  

Mesh:

Year:  2019        PMID: 31847524     DOI: 10.4149/neo_2019_190309N206

Source DB:  PubMed          Journal:  Neoplasma        ISSN: 0028-2685            Impact factor:   2.575


  6 in total

1.  Software simulation of tumour motion dose effects during flattened and unflattened ITV-based VMAT lung SBRT.

Authors:  Marta Adamczyk; Marta Kruszyna-Mochalska; Anna Rucińska; Tomasz Piotrowski
Journal:  Rep Pract Oncol Radiother       Date:  2020-06-11

2.  Analysis of the planned, delivered dose distributions and quality assurance for helical tomotherapy and volumetric modulated arc therapy in locally advanced non-small cell lung cancer.

Authors:  Pitchayaponne Klunklin; Tamisa Manoharn; Somsak Wanwilairat; Wannapha Nobnop; Anirut Watcharawipha; Imjai Chitapanarux
Journal:  Rep Pract Oncol Radiother       Date:  2021-12-30

3.  Evaluation of lung tumor motion in a large sample: Target-related and clinical factors influencing tumor motion based on four-dimensional CT.

Authors:  Fengxiang Li; Yanlin Qu; Tingting Zhang; Zhen Cui; Xin Sun; Tao Zhang; Jianbin Li
Journal:  Cancer Med       Date:  2021-09-14       Impact factor: 4.452

4.  Erring Characteristics of Deformable Image Registration-Based Auto-Propagation for Internal Target Volume in Radiotherapy of Locally Advanced Non-Small Cell Lung Cancer.

Authors:  Benjamin J Rich; Benjamin O Spieler; Yidong Yang; Lori Young; William Amestoy; Maria Monterroso; Lora Wang; Alan Dal Pra; Fei Yang
Journal:  Front Oncol       Date:  2022-07-22       Impact factor: 5.738

Review 5.  Treatment-integrated imaging, radiomics, and personalised radiotherapy: the future is at hand.

Authors:  Julian Malicki; Tomasz Piotrowski; Ferran Guedea; Marco Krengli
Journal:  Rep Pract Oncol Radiother       Date:  2022-09-19

6.  Dose delivery accuracy on helical tomotherapy for 4-dimensional tumor motion - a phantom study.

Authors:  Raghavendra Holla; David Khanna; V K Sathiya Narayanan
Journal:  Rep Pract Oncol Radiother       Date:  2021-06-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.