Literature DB >> 31842850

Systematic review on the needle and suture types for uterine compression sutures: a literature review.

Shinya Matsuzaki1, Mariko Jitsumori2, Takeya Hara2, Satoko Matsuzaki3, Satoshi Nakagawa2, Tatsuya Miyake2, Tsuyoshi Takiuchi2, Aiko Kakigano4, Eiji Kobayashi2, Takuji Tomimatsu2, Tadashi Kimura2.   

Abstract

BACKGROUND: This study aimed to identify and review associations between the types of sutures used for uterine compression suture (UCS) and its outcomes in postpartum hemorrhage.
METHODS: An electronic search using PubMed and Scopus databases was performed. We included the English articles reported from January 1, 1997, to May 31, 2017, using search words or terms regarding the types of suture and needle used for UCSs. We only included studies describing the sutures in the systematic review.
RESULTS: We found 196 studies and included 76 (38.8%) in our analysis. We collected data on maternal outcomes for 924 patients and categorized them. Of the 76 studies, suture sizes 0, 1, and 2 were used in 6, 44, and 32 articles, respectively (some studies used multiple sutures). Of the 45 studies mentioning the needles, curved and straight needles were used in 35 and 10, respectively. The results of our review revealed that about 80% of previous articles used Catgut and Polyglactin 910 sutures. Because no studies that compared the efficacy of different size of sutures were identified, we investigated the differences using the cases reported in previous studies mentioned above. In the first analysis, we compared the uterine preservation rate between size 1 and size 2 sutures. We found no significant difference in uterine preservation rate (92.8%: size 1 vs. 94.2%: size 2, p > 0.05) but found significant difference in transfusion rate (62.4% vs. 79.1%, p < 0.01). With the hypothesis that non-transfusion cases were less severe, we excluded these cases from second analysis. Although our second analysis of only Catgut or Polyglactin showed strong selection bias, we observed that uterine preservation rate was significantly higher in cases with size 2 suture than in those with size 1 suture (86.9% vs. 93.5%, p = 0.033).
CONCLUSIONS: Our systematic review showed that approximately 80% of cases were treated by Catgut and Polyglactin 910. Due to the heterogeneity of cases included in this review, it is difficult to estimate which suture is better for UCSs. More robust studies are necessary to enable the identification of the superior suture for performing UCSs.

Entities:  

Keywords:  Needle; Suture size; Uterine compression suture

Mesh:

Substances:

Year:  2019        PMID: 31842850      PMCID: PMC6916157          DOI: 10.1186/s12893-019-0660-z

Source DB:  PubMed          Journal:  BMC Surg        ISSN: 1471-2482            Impact factor:   2.102


Background

Severe hemorrhage after birth is known as postpartum hemorrhage (PPH), and it is a major reason for maternal death worldwide, with an incidence in 1–2% of live births. Uterine compression sutures (UCSs) have been indicated to manage PPH [1-3]. Reported UCS techniques have shown similar success rates (76–100%) for uterine preservation [4-14], and these reports have proven that UCSs are essential treatment options for PPH. Although many UCS techniques are considered valuable, differences in the efficacies of different needles and sutures have not been well studied as most studies have focused on modification of the UCS procedure and in turn disregarded the influence of the choice of needles and sutures used. Thus, we focused on the efficacies of needles and sutures used for UCSs to identify the best ones for UCSs and help improve patient outcomes. In our previous study, we performed literature search on suture and needle types used for UCSs; however, we only investigated the results on dedicated needles for UCSs [15]. Here, we present the results of our systematic literature review to compare the efficacy of different types of needle and suture used for UCSs.

Methods

Factors

We conducted a systematic search of articles published between January 1, 1997, and May 31, 2017, using PubMed and Scopus databases, as performed in our previous study [15, 16]. We included only English articles and excluded articles reported before 1997. The search strategy involved the use of these keywords: uterine compression suture, B-Lynch, and uterine preservation surgery. Articles on B-Lynch sutures were also included.

Article retrieval

We reviewed the retrieved articles following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines [17]. Two authors (SM and MJ) independently performed the study selection (screening of titles, abstracts, and full texts of relevant articles) as described [18]. Many articles we found had insufficient information regarding the needles; thus, we chose all those that included information on sutures with or without needles for UCSs (suture sizes were those defined by the United States Pharmacopeia). We excluded articles that did not mention the suture type or uterine preservation rate. The outcomes and complication rates for each suture type were not available in all articles. Given the reported similarity in high uterine preservation rates among the types of UCS [4], we assumed equivalent efficacies among UCS techniques in our analysis. As mentioned in our previous study, our institution standardized the timing for performing UCSs to avoid performing unnecessary sutures [6]. However, most publications have failed to mention UCS timings, and these certainly vary among facilities; thus, comparing the different needle and suture types to determine the efficacy of UCSs was challenging. We limited our analysis to transfused cases and to those using Polyglactin 910 or Catgut sutures for maximum alignment, to compare the uterine preservation rates between suture sizes 1 and 2 in studies with similar conditions. Thus, we assumed that all patients who underwent hysterectomy had received transfusions. Our primary aim with this study was to investigate the efficacies of UCSs with different needle and suture types. Our secondary aim was to reveal the needle and suture types used in previous studies.

Statistical analysis

Statistical analyses were performed using JMP Pro (version 13.1; SAS Institute, Tokyo, Japan). Categorical variables were analyzed using χ2 and Fisher’s tests and continuous variables using one-way analysis of variance. P-value < 0.05 was considered to indicate statistical significance.

Results

Search results

Figure 1 presents a flow diagram of the literature search. Of the 196 nonduplicate records identified from the electronic database search and other sources, we retrieved 196 full-text articles after screening the titles and abstracts. After excluding the articles that did not meet the inclusion criteria (56 case series and 20 case reports), we included 76 articles for analysis. Additional file 1: Table S1 and Additional file 2: Table S2 provide detailed information and references of all included articles.
Fig. 1

Flow diagram of study selection for the systematic review

Flow diagram of study selection for the systematic review

Results of the literature review on the type of needles and sutures used for UCS

All 76 articles described UCSs with suture size and 45 included needle types. Of the 76 studies, suture sizes 0, 1, and 2 were used in 6, 44, and 32 articles, respectively (some studies included procedures with different suture and needle types; Table 1). Of the 45 studies that included needle types, 35 used curved needles and 10 straight needles. Sutures size 1 and curved needles were used most often. Determining the association between the procedure efficacy and the needle types was difficult because various types of needles were used during the UCSs; thus, we focused on the differences among suture types. The results of our review showed that about 80% of the studies included used Catgut or Polyglactin 910 sutures (19 and 45 studies, respectively).
Table 1

Summary of published results on the review of the type of sutures used for uterine compression sutures

Suture sizeSuture materialNumber or studiesaTotal cases included in the studiesNeedle types
CurvedStraightNA
No. 0Polyglactin 910413Shape300
Bodied000
NA001
Catgut15NA
Poliglecaprone 2511NA010
No. 1Polyglactin 91025355Shape300
Bodied510
NA619
Catgut785Shape110
Bodied200
NA012
Polydioxanone22NA
Poliglecaprone 25336Bodied100
NA002
Others798Shape210
Bodied100
NA003
No. 2Polyglactin 91016128Shape000
Bodied200
NA329
Catgut11155Shape000
Bodied300
NA215
Polydioxanone11NA
Others425Shape000
Bodied100
NA012

aSome studies overlapped

Summary of published results on the review of the type of sutures used for uterine compression sutures aSome studies overlapped

Transfusion rate

The transfusion rates ranged from 0 to 100% and varied between studies, with 42 studies mentioning about transfusion rate (including ≥5 cases of UCS). Of the 42 studies, 26 (61.9%) showed more than 80% transfusion rate, 13 (31.0%) showed 10–79%, and 3 (7.1%) showed 0–9%.

Comparison of the UCS surgical outcomes for different suture sizes

Table 2 shows the surgical outcomes for each suture size. A significantly lower transfusion rate was observed in the group of UCSs performed with size 1 sutures than in the group of UCSs performed with size 2 sutures (62.4% vs. 79.1%, respectively, p < 0.01). However, the uterine preservation rates did not significantly differ between the groups (92.8% vs. 94.2%, p = 0.249). Four uterine necroses (0.67% of the total 596 UCSs) occurred in procedures performed with size 1 sutures, and none occurred in those performed with size 2 sutures. As shown in Table 2, we found no significant differences in the rates of severe complications (complications needing surgical interventions) after procedures performed with either size 1 or size 2 sutures (p = 0.332).
Table 2

Review of the suture types used for uterine compression sutures in previous studies (all cases)

Suture sizeSuture materialTotal cases included in the studiesEstimated mean blood loss (ml)Transfusion rateUterine preservation rateSevere complication ratea
No. 0Polyglactin 9101330829/10 (90%)13/13 (100%)0
Catgut528305/5 (100%)5/5 (100%)0
No. 1Polyglactin 9103751921211/372 (56.7%)342/375 (91.2%)3/375 (0.8%)
Catgut85138034/40 (85.0%)82/83 (98.8%)b1/83 (1.2%) b
Others136230997/136 (71.3%)127/136 (93.4%)1/136(0.74%)
Total5962039342/548 (62.4%)551/594 (92.8) b5/594 (0.91%) b
No. 2Polyglactin 910128213592/102 (90.2%)120/128 (93.8%)0/128 (0%)
Catgut155236178/118 (66.1%)146/155 (94.2%)0/124 (0%)
Others26253119/19 (100%)25/26 (96.2%)0/19 (0%)
Total3092249189/239 (79.1%)291/309 (94.2%)0/271 (0%)

aSevere complications are defined as the need for surgical intervention to treat complications due to uterine compression sutures

bTwo maternal deaths due to the hypertention disorder of pregnancy were excluded

Review of the suture types used for uterine compression sutures in previous studies (all cases) aSevere complications are defined as the need for surgical intervention to treat complications due to uterine compression sutures bTwo maternal deaths due to the hypertention disorder of pregnancy were excluded We performed second analysis by limiting our analyses to cases requiring transfusions with the hypothesis that non-transfusion cases were less severe. We only included the cases using Polyglactin 910 or Catgut sutures in this analysis. The uterine preservation rate was significantly higher in the procedures performed with size 2 sutures than in those performed with size 1 sutures (Table 3; 86.9% vs. 93.5%, respectively, p = 0.033). Next, we compared the outcomes after size 1 and 2 suture UCSs (Polyglactin 910 and catgut) in cases of uterine atony. There was no significant difference in the rates of transfusion and uterine preservation in the analysis of limited transfusion cases of uterine atony (89.3% vs. 92.5%, p = 0.428) (Table 3 and Additional file 3: Table S3).
Table 3

Comparison of uterine preservation rate among different suture sizes

Suture sizeSuture materialTotal cases included in the studiesMean blood loss (ml)Transfusion rateUterine preservationSevere complication ratea
No. 1Total594b2039342/548(62.4%)c551/594 (92.8%)d5/594 (0.84%)e
Limited transfusion cases (Polyglactin 910 and catgut)213/245 (86.9%)f
Limited transfusion and uterine atony cases (Polyglactin 910 and catgut)142/159 (89.3%)g
No. 2Total3092249189/239 (79.1%)c291/309 (94.2%)d0/309(0%)e
Limited transfusion cases (Polyglactin 910 and catgut)159/170 (93.5%)f
Limited transfusion and uterine atony cases (Polyglactin 910 and catgut)135/146 (92.5%)g

Bold indicates statistical significance

aSevere complications are defined as need for surgical intervention to treat complications due to uterine compression sutures

bTwo maternal deaths due to the hypertention disorder of pregnancy were excluded

Statistical analysis was performed among b, c, d, and e. The p values are listed below

cp = 0.000

dp = 0.249

ep = 0.332

fp = 0.033

gp = 0.428

Comparison of uterine preservation rate among different suture sizes Bold indicates statistical significance aSevere complications are defined as need for surgical intervention to treat complications due to uterine compression sutures bTwo maternal deaths due to the hypertention disorder of pregnancy were excluded Statistical analysis was performed among b, c, d, and e. The p values are listed below cp = 0.000 dp = 0.249 ep = 0.332 fp = 0.033 gp = 0.428

Discussion

The key finding of our study was that approximately 80% cases were treated by Catgut and Polyglactin 910 sutures with size 1 or 2 for UCSs. This systematic review is the first to compare different sutures (sizes 1 or 2) used for UCSs. However, we conclude that it is difficult to estimate which suture is better for UCSs due to the heterogeneity of cases included in this review. Our review also found that transfusion rates varied from 0 to 100% and more than half of the studies showed high transfusion rate (≥80%). First, UCS was indicated only in severe hemorrhage cases [5]. However, recently, UCS is used in mild cases, even though “prophylactic UCS” is currently performed [19]. We considered that these differences might reflect the differences in the initiation times of UCSs in each study. We compared different types of sutures used for UCSs; however, the analysis was difficult because when performing UCSs for mild cases, the transfusion rate was low and the uterine preservation rate may have been high with the use of UCSs. For example, El Refaeey AEA et al investigated 108 cases [20], which included the largest number of UCSs in this review, and reported the rates of transfusion and uterine preservation of only 9.3% (10 of 108) and 100% (108/108) cases, respectively. The authors performed “early” intervention, resulting in the treatment of less severe cases and reduction of the rate of transfusion. According to our results, the transfusion rate in UCS cases performed with size 1 sutures was significantly lower than that in cases performed with size 2 sutures (62.4% vs. 79.1%, respectively, p < 0.01), but the uterine preservation rates were similar between the same groups (92.8% vs. 94.2%, respectively, p = 0.249). Therefore, we attempted to limit the analysis of uterine preservation rates to transfused cases and to only analyze cases using Polyglactin 910 or Catgut sutures to reduce the difference in severity between the cases using size 1 and 2 sutures. Although this analysis showed a strong bias, sub-analysis showed that the uterine preservation rate in transfused cases was higher when performed with size 2 sutures than with size 1 sutures (86.9%: size 1 vs. 93.5%: size 2, p = 0.033). Moreover, there were no between-group differences in terms of complication rate. Although our systematic review failed to investigate differences in terms of efficacy among needle types, we found that three dedicated needles have already been reported: poliglecaprone 25, No.1 suture made by Ethicon Endo-Surgery (W3709) for B-Lynch technique [21, 22]; a curved needle with customized sizable, reported by Yano et al. for MY suture [23]; and a straight super blunt needle reported by Matsuzaki et al. [15] These studies failed to fulfill our criteria and were excluded. Whether dedicated needles can improve the uterine preservation rate remains unclear. The strength of our study lies in it being the first review to compare the efficacies of different needles and sutures for UCSs. Although it was difficult to conclude the superiority of needle and suture for UCS, our data may be useful to investigate the efficacy of needles and sutures in future studies. Second, our results also provide useful information, such as the needle and suture types being used for UCS as well as the transfusion rates of previous studies. We are aware of our study’s limitations. First, because we did not investigate the efficacy of different UCSs, the efficacy of different sutures was analyzed under the assumption that UCS techniques are equally effective and show the same uterine preservation rate. This assumption may have strongly biased the result of our analysis. Second, we could not investigate the efficacies of different sutures under the same conditions because PPH often occurs because of different causes and because UCS timing varies according to clinicians’ judgment. To adjust the severity of conditions, we limited the analysis of uterine preservation rate to cases requiring transfusions; however, this selection may also have caused biases. Third, we could not classify the PPH cases according to their causes, and we had to individually determine the efficacies of sutures. Moreover, the relationship between uterine preservation rate and different needles or suture was not compared in the same study, negating the feasibility of a needle- or suture-specific discussion. Fourth, we could not investigate or exclude the effect of adjunctive treatments such as uterine artery ligation for UCS; thus, unmeasured bias may exist in the analysis. Fifth, because previous studies lacked detailed information, we could not determine the timing of transfusion. Therefore, these results may be biased because our hypothesis was that non-transfusion cases exhibit less severity. As mentioned above, our study has strong biases; however, we believe it is an acceptable method. In order to resolve these biases, better study designs, such as case-control and cohort studies, and perhaps even more robust studies, such as randomized control trials, are expected to provide better evidence regarding the needles and sutures used for UCSs.

Conclusions

A systematic review determining the associations between size 1 and size 2 sutures used for UCS and its outcomes in postpartum hemorrhage showed that approximately 80% of cases were treated by Catgut and Polyglactin 910. We also revealed that it is difficult to investigate the efficacy of UCSs among the different needles and sutures used based on the current knowledge. Comparisons between size 1 and size 2 sutures in more robust studies are necessary to enable the identification of the superior suture for performing UCSs. Additional file 1: Table S1. Detailed information of the sutures and needles in published studies Additional file 2: Table S2. References of all publications on uterine compression sutures that satisfied our criteria Additional file 3: Table S3 Comparison of uterine preservation rate among different suture sizes in uterine atony cases
  23 in total

1.  The B-Lynch surgical technique for the control of massive postpartum haemorrhage: an alternative to hysterectomy? Five cases reported.

Authors:  C B-Lynch; A Coker; A H Lawal; J Abu; M J Cowen
Journal:  Br J Obstet Gynaecol       Date:  1997-03

2.  Investigation of perioperative complications associated with use of uterine compression sutures.

Authors:  Yosuke Suzuki; Shinya Matsuzaki; Kazuya Mimura; Keiichi Kumasawa; Takuji Tomimatsu; Masayuki Endo; Tadashi Kimura
Journal:  Int J Gynaecol Obstet       Date:  2017-07-19       Impact factor: 3.561

Review 3.  Uterine compression sutures for postpartum hemorrhage: an overview.

Authors:  Shigeki Matsubara; Hitoshi Yano; Akihide Ohkuchi; Tomoyuki Kuwata; Rie Usui; Mitsuaki Suzuki
Journal:  Acta Obstet Gynecol Scand       Date:  2013-02-09       Impact factor: 3.636

4.  A novel 'uterine sandwich' for haemorrhage at caesarean section for placenta praevia.

Authors:  Shigeki Matsubara; Tomoyuki Kuwata; Yosuke Baba; Rie Usui; Hirotada Suzuki; Hironori Takahashi; Akihide Ohkuchi; Mitsuaki Suzuki
Journal:  Aust N Z J Obstet Gynaecol       Date:  2014-02-08       Impact factor: 2.100

Review 5.  A systematic review of maternal near miss and mortality due to postpartum hemorrhage.

Authors:  Salome Maswime; Eckhart Buchmann
Journal:  Int J Gynaecol Obstet       Date:  2017-01-24       Impact factor: 3.561

6.  Short interpregnancy interval after B-Lynch uterine compression suture: a case report.

Authors:  A Nishikawa; S Matsuzaki; K Mimura; T Kanagawa; T Kimura
Journal:  Clin Exp Obstet Gynecol       Date:  2016       Impact factor: 0.146

7.  Hemostatic suturing technique for uterine bleeding during cesarean delivery.

Authors:  J H Cho; H S Jun; C N Lee
Journal:  Obstet Gynecol       Date:  2000-07       Impact factor: 7.661

8.  A Case Report and Literature Review of Midtrimester Termination of Pregnancy Complicated by Placenta Previa and Placenta Accreta.

Authors:  Satoko Matsuzaki; Shinya Matsuzaki; Yutaka Ueda; Yusuke Tanaka; Mamoru Kakuda; Takeshi Kanagawa; Tadashi Kimura
Journal:  AJP Rep       Date:  2014-12-18

Review 9.  A case of acute Sheehan's syndrome and literature review: a rare but life-threatening complication of postpartum hemorrhage.

Authors:  Shinya Matsuzaki; Masayuki Endo; Yutaka Ueda; Kazuya Mimura; Aiko Kakigano; Tomomi Egawa-Takata; Keiichi Kumasawa; Kiyoshi Yoshino; Tadashi Kimura
Journal:  BMC Pregnancy Childbirth       Date:  2017-06-14       Impact factor: 3.007

Review 10.  New dedicated blunt straight needles and sutures for uterine compression sutures: a retrospective study and literature review.

Authors:  Shinya Matsuzaki; Masayuki Endo; Takuji Tomimatsu; Satoshi Nakagawa; Satoko Matsuzaki; Tatsuya Miyake; Tsuyoshi Takiuchi; Aiko Kakigano; Kazuya Mimura; Yutaka Ueda; Tadashi Kimura
Journal:  BMC Surg       Date:  2019-03-11       Impact factor: 2.102

View more
  5 in total

1.  Uterine necrosis, infection, and subinvolution: complications observed after combined application of modified B-Lynch suture and vascular ligation.

Authors:  Linfeng Luo; Junhui Wan; Xinping Chen; Huan Zhang; Minjie Zhang; Qi Chen
Journal:  J Int Med Res       Date:  2021-05       Impact factor: 1.671

2.  Antenatal diagnosis of placenta accreta spectrum after in vitro fertilization-embryo transfer: a systematic review and meta-analysis.

Authors:  Shinya Matsuzaki; Yoshikazu Nagase; Tsuyoshi Takiuchi; Aiko Kakigano; Kazuya Mimura; Misooja Lee; Satoko Matsuzaki; Yutaka Ueda; Takuji Tomimatsu; Masayuki Endo; Tadashi Kimura
Journal:  Sci Rep       Date:  2021-04-28       Impact factor: 4.379

Review 3.  Placenta Accreta Spectrum Disorder Complicated with Endometriosis: Systematic Review and Meta-Analysis.

Authors:  Shinya Matsuzaki; Yutaka Ueda; Yoshikazu Nagase; Satoko Matsuzaki; Mamoru Kakuda; Sahori Kakuda; Hitomi Sakaguchi; Tsuyoshi Hisa; Shoji Kamiura
Journal:  Biomedicines       Date:  2022-02-06

4.  Obstetric Outcomes of Pregnancy After Uterine Artery Embolization.

Authors:  Mariko Jitsumori; Shinya Matsuzaki; Masayuki Endo; Takeya Hara; Takuji Tomimatsu; Satoko Matsuzaki; Tatsuya Miyake; Tsuyoshi Takiuchi; Aiko Kakigano; Kazuya Mimura; Eiji Kobayashi; Yutaka Ueda; Tadashi Kimura
Journal:  Int J Womens Health       Date:  2020-03-06

Review 5.  Maternal and Fetal Outcomes after Prior Mid-Trimester Uterine Rupture: A Systematic Review with Our Experience.

Authors:  Shinya Matsuzaki; Tsuyoshi Takiuchi; Takeshi Kanagawa; Satoko Matsuzaki; Misooja Lee; Michihide Maeda; Masayuki Endo; Tadashi Kimura
Journal:  Medicina (Kaunas)       Date:  2021-11-24       Impact factor: 2.430

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.