Literature DB >> 31841607

The Effect of Configuration of Rhombic Cannulated Screws on Internal Fixation of Femoral Neck Fractures.

Jialiang Guo, Weichong Dong, Yingchao Yin, Ruipeng Zhang, Zhiyong Hou, Yingze Zhang.   

Abstract

Femoral neck fractures are commonly encountered clinical problems, especially in patients with osteoporosis, and have high morbidity and mortality. Internal fixation of femoral neck fractures using 3 cannulated screws placed in an inverse triangle configuration is commonly performed. Recently, the use of 4 cannulated screws in a rhombic configuration has been proposed. The aim of this study was to investigate the outcomes of femoral neck fractures treated using either an inverse triangle or rhombic configuration to determine which had a better clinical prognosis. A total of 138 consecutive patients without any previous hip surgery who had femoral neck fractures treated with cannulated compression screws in either an inverse triangle or rhombic configuration were reviewed. Patients' demographic and radiological data were collected from the authors' institutional database. The authors found that the rhombic configuration did not have a better result in decreasing complications, such as femoral neck shortening or screw exit, or in Harris Hip Scores and other clinical prognoses compared with the inverse triangle configuration. In addition, the technique used for applying 4 screws (especially the posterior ones) needs to be improved, so until then, using 3 screws in an inverse triangle configuration remains the gold standard for the treatment of femoral neck fractures. [Orthopedics. 2020; 43(2):e72-e78.]. Copyright 2019, SLACK Incorporated.

Entities:  

Year:  2019        PMID: 31841607     DOI: 10.3928/01477447-20191212-03

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  2 in total

1.  [Research progress in biomechanics of common internal fixation for femoral neck fracture].

Authors:  Fuyang Wang; Yuchen Liu; Liangliang Cheng; Dewei Zhao
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-07-15

2.  Comparison of the Effect of Rhombic and Inverted Triangle Configurations of Cannulated Screws on Internal Fixation of Nondisplaced Femoral Neck Fractures in Elderly Patients.

Authors:  Jian Zhu; Xiangtian Deng; Hongzhi Hu; Xiaodong Cheng; Zhanchao Tan; Yingze Zhang
Journal:  Orthop Surg       Date:  2022-03-18       Impact factor: 2.071

  2 in total