Literature DB >> 31833801

Safety and Tolerability of Insulin Aspart Biosimilar SAR341402 Versus Originator Insulin Aspart (NovoLog) When Used in Insulin Pumps in Adults with Type 1 Diabetes: A Randomized, Open-Label Clinical Trial.

James Thrasher1, Sarit Polsky2, Lionel Hovsepian3, Irene Nowotny4, Suzanne Pierre3, Béatrice Bois De Fer3, Anuj Bhargava5, Bhaswati Mukherjee3, Satish K Garg2.   

Abstract

Background: The aim was to assess the safety and tolerability of the insulin aspart biosimilar/follow-on product SAR341402 (100 U/mL solution; SAR-Asp) and originator insulin aspart (100 U/mL; NN-Asp; NovoLog®) self-administered through an insulin pump. Materials and
Methods: This randomized, open-label, 2 × 4-week crossover study enrolled 45 adults with type 1 diabetes (T1D). Participants were randomized 1:1 to the treatment sequence SAR-Asp/NN-Asp or NN-Asp/SAR-Asp. The basal and prandial insulin doses were individually titrated. The primary outcome was the number of participants with at least one infusion set occlusion (infusion set change due to failure-to-correct hyperglycemia [plasma glucose ≥250 mg/dL] by insulin pump bolus) during the 4-week treatment. The main secondary outcome was the number of participants with at least one episode of unexplained hyperglycemia (regardless of correction by an insulin pump bolus without apparent material defect, medical, dietary, insulin dosing reason, or pump problem).
Results: The number of participants reporting ≥1 infusion set occlusion were similar between treatments: 14/43 on SAR-Asp (33 events) and 12/43 on NN-Asp (24 events). The estimated difference in infusion set occlusion risk for SAR-Asp versus NN-Asp was 4.1% (95% confidence interval: -9.3% to 17.4%). The number of participants with ≥1 episode of unexplained hyperglycemia was similar between treatments (31/43 on SAR-Asp [154 events]; 32/43 on NN-Asp [175 events]). Hypoglycemia, treatment-emergent adverse events, hypersensitivity, and injection site reactions were similar between treatments. Conclusions: SAR-Asp and NN-Asp were well tolerated and had similar infusion set occlusions over a 4-week period in insulin pump users with T1D.

Entities:  

Keywords:  Biosimilar; Continuous subcutaneous insulin infusion; Follow-on product; Infusion set occlusion; Insulin aspart; SAR341402

Year:  2020        PMID: 31833801     DOI: 10.1089/dia.2019.0446

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  2 in total

1.  A single-dose euglycaemic clamp study in two cohorts to compare the exposure of SAR341402 (insulin aspart) Mix 70/30 with US- and European-approved versions of insulin aspart Mix 70/30 and SAR341402 rapid-acting solution in subjects with type 1 diabetes.

Authors:  Christoph Kapitza; Leszek Nosek; Wolfgang Schmider; Lenore Teichert; Bhaswati Mukherjee; Irene Nowotny
Journal:  Diabetes Obes Metab       Date:  2020-12-10       Impact factor: 6.577

2.  Pharmacokinetic and pharmacodynamic similarity between SAR341402 insulin aspart and Japan-approved NovoRapid in healthy Japanese subjects.

Authors:  Masanari Shiramoto; Tatsuya Yoshihara; Wolfgang Schmider; Hiroki Takagi; Irene Nowotny; Miyuki Kajiwara; Hideya Muto
Journal:  Sci Rep       Date:  2021-11-25       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.