Literature DB >> 31831437

Flexible Body-Conformal Ultrasound Patches for Image-Guided Neuromodulation.

Vida Pashaei, Parisa Dehghanzadeh, George Enwia, Mahdi Bayat, Steve J A Majerus, Soumyajit Mandal.   

Abstract

The paper presents the design and validation of body-conformal active ultrasound patches with integrated imaging and modulation modalities for image-guided neural therapy. A mechanically-flexible linear 64-element array of piezoelectric transducers with a resonance frequency of 5 MHz was designed for nerve localization. A second 8-element array using larger elements was integrated on the wearable probe for low intensity focused ultrasound neuromodulation at a resonance frequency of 1.3 MHz. Full-wave simulations were used to model the flexible arrays and estimate their generated pressure profiles. A focal depth of 10-20 mm was assumed for beamforming and focusing to support modulation of the vagus, tibial, and other nerves. A strain sensor integrated on the probe provides patient-specific feedback information on array curvature for real-time optimization of focusing and image processing. Each patch also includes high voltage (HV) multiplexers, transmit/receive switches, and pre-amplifiers that simplify connectivity and also improve the signal-to-noise ratio (SNR) of the received echo signals by  ∼ 5 dB. Experimental results from a flexible prototype show a sensitivity of 80 kPa/V with  ∼ 3 MHz bandwidth for the modulation and 20 kPa/V with  ∼ 6 MHz bandwidth for the imaging array. An algorithm for accurate and automatic localization of targeted nerves based on using nearby blood vessels (e.g., the carotid artery) as image markers is also presented.

Entities:  

Mesh:

Year:  2019        PMID: 31831437     DOI: 10.1109/TBCAS.2019.2959439

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  5 in total

Review 1.  Flexible Electronics and Devices as Human-Machine Interfaces for Medical Robotics.

Authors:  Wenzheng Heng; Samuel Solomon; Wei Gao
Journal:  Adv Mater       Date:  2022-02-25       Impact factor: 32.086

2.  Stimulation of the hepatoportal nerve plexus with focused ultrasound restores glucose homoeostasis in diabetic mice, rats and swine.

Authors:  Victoria Cotero; John Graf; Hiromi Miwa; Zall Hirschstein; Khaled Qanud; Tomás S Huerta; Ningwen Tai; Yuyan Ding; Kevin Jimenez-Cowell; Jacquelyn N Tomaio; Weiguo Song; Alex Devarajan; Tea Tsaava; Radhika Madhavan; Kirk Wallace; Evelina Loghin; Christine Morton; Ying Fan; Tzu-Jen Kao; Kainat Akhtar; Meghana Damaraju; Linda Barenboim; Teresa Maietta; Jeffrey Ashe; Kevin J Tracey; Thomas R Coleman; Dino Di Carlo; Damian Shin; Stavros Zanos; Sangeeta S Chavan; Raimund I Herzog; Chris Puleo
Journal:  Nat Biomed Eng       Date:  2022-03-31       Impact factor: 29.234

3.  Design and Optimization of Ultrasound Phased Arrays for Large-Scale Ultrasound Neuromodulation.

Authors:  Sheikh Jawad Ilham; Zeinab Kashani; Mehdi Kiani
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2022-02-17       Impact factor: 3.833

4.  Flexible ultrasound transceiver array for non-invasive surface-conformable imaging enabled by geometric phase correction.

Authors:  Jeffrey Elloian; Jakub Jadwiszczak; Volkan Arslan; Jeffrey D Sherman; David O Kessler; Kenneth L Shepard
Journal:  Sci Rep       Date:  2022-09-28       Impact factor: 4.996

5.  Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays.

Authors:  Chonghe Wang; Baiyan Qi; Muyang Lin; Zhuorui Zhang; Mitsutoshi Makihata; Boyu Liu; Sai Zhou; Yi-Hsi Huang; Hongjie Hu; Yue Gu; Yimu Chen; Yusheng Lei; Taeyoon Lee; Shu Chien; Kyung-In Jang; Erik B Kistler; Sheng Xu
Journal:  Nat Biomed Eng       Date:  2021-07-16       Impact factor: 25.671

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.