Yu Liu1, Ji Qian1, Xin Yang2, Bao Di1, Juan Zhou2.
Abstract
BACKGROUND: Traditional measurements of apple seedling roots often rely on manual measurements and existing root scanners on the market. Manual measurement requires a lot of labor and time, and subjective reasons may cause the uncertainty of data; root scanners have limited scanning size and expensive. In case of fruit roots, coverage and occlusion issues will occur, resulting in inaccurate results, but our research solved this problem.Entities:
Keywords: Apple root system; Image preprocessing; Labview; Morphological parameters
Year: 2019 PMID: 31827581 PMCID: PMC6905017 DOI: 10.1186/s13007-019-0535-4
Source DB: PubMed Journal: Plant Methods ISSN: 1746-4811 Impact factor: 4.993
Independent sample test
| Levin test | T-test for mean equality | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Significance | Degrees of freedom | Significance (double tail) | Average deviation | Standard error difference | 99% confidence interval of the difference | ||||
| Lower limit | Upper limit | ||||||||
| Surface area | 0.020 | 0.889 | 0.073 | 58.000 | 0.942 | 2.779 | 38.061 | − 98.589 | 104.146 |
| 0.073 | 57.992 | 0.942 | 2.779 | 38.061 | − 98.590 | 104.147 | |||
| Diameter | 0.003 | 0.955 | 0.013 | 58.000 | 0.990 | 0.001 | 0.080 | − 0.211 | 0.213 |
| 0.013 | 58.000 | 0.990 | 0.001 | 0.080 | − 0.211 | 0.213 | |||
| Length | 0.015 | 0.904 | − 0.023 | 58.000 | 0.982 | − 1.813 | 78.634 | − 211.237 | 207.610 |
| − 0.023 | 57.981 | 0.982 | − 1.813 | 78.634 | − 211.240 | 207.613 | |||
| Volume | 0.07 | 0.932 | 0.26 | 57.000 | 0.991 | 0.030 | 1.166 | 1.166 | 3.136 |
| 0.26 | 56.850 | 0.991 | 0.030 | 1.166 | 1.166 | 3.137 | |||
Error analysis table
| Standard deviation | Absolute standard error | Relative error | ||
|---|---|---|---|---|
| Labview | WinRHIZO 2016 | |||
| Surface area | 146.520 | 148.300 | 83.355 | 0.480 |
| Diameter | 0.309 | 0.309 | 0.031 | 0.083 |
| Length | 307.310 | 301.750 | 54.390 | 0.080 |
| Volume | 4.440 | 4.440 | 0.389 | 0.110 |
Fig. 1Comparison of the two measurement methods. x, Labview measurement value; y, WinRHIZO 2016 measurement value; a root surface area analysis chart; b average root diameter analysis chart; c root length chart; d root volume analysis chart
Calibration data
| Measurement parameters | Gain | Offset | Determination coefficient |
|---|---|---|---|
| Surface area | 1.0092 | − 8.0577 | 0.99393 |
| Diameter | 0.9966 | 0.0032 | 0.99288 |
| Length | 0.9796 | 47.6400 | 0.99508 |
| Volume | 0.9973 | 0.0432 | 0.99282 |
The gain, offset and determination coefficients of each parameter were calculated
Fig. 2Seedling root collection
Fig. 3Schematic diagram of the system principle
Fig. 4System flow chart
Fig. 5Preprocessing image. a comparison of B9 layering root image before and after processing; b comparison of SH40 root image before and after processing; c comparison of B9 seedling root system before and after processing
Fig. 6Program code