Literature DB >> 3182479

Direct measurement of static chest wall compliance in animal and human neonates.

G M Davis1, A L Coates, A Papageorgiou, M A Bureau.   

Abstract

The measurement of pulmonary mechanics has been developed extensively for adults, and these techniques have been applied directly to neonates and infants. However, the compliant chest wall of the infant frequently predisposes to chest wall distortion, especially when there is a low dynamic lung compliance (CL,dyn). We describe a technique of directly measuring the static chest wall compliance (Cw,st), developed initially in the newborn lamb and subsequently applied to the premature neonate with chest wall distortion. The mean CL,dyn in seven intubated newborn lambs in normoxia was 2.45 +/- 0.41 ml.cmH2O-1.kg-1, whereas Cw,st was 11.81 +/- 0.25 ml.cmH2O-1.kg-1. These values did not change significantly in seven animals breathing through a tight-fitting face mask or with hypercapnia-induced tachypnea. For the eight premature infants the mean CL,dyn was 1.35 +/- 0.36 ml.cmH2O-1.kg-1, whereas the mean Cw,st was 3.16 +/- 1.01 ml.cmH2O-1.kg-1. This study shows that, under relaxed conditions when measurements of static compliance are performed, the chest wall is more compliant than the lung. The measurement of Cw,st may thus be used to determine the contribution of the respiratory musculature in stabilizing the chest wall.

Entities:  

Mesh:

Year:  1988        PMID: 3182479     DOI: 10.1152/jappl.1988.65.3.1093

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  4 in total

Review 1.  Respiratory morbidity and lung function in preterm infants of 32 to 36 weeks' gestational age.

Authors:  Andrew A Colin; Cynthia McEvoy; Robert G Castile
Journal:  Pediatrics       Date:  2010-06-07       Impact factor: 7.124

2.  A model of ventilation used to interpret newborn lamb respiratory signals.

Authors:  Virginie Le Rolle; Alfredo I Hernandez; Guy Carrault; Nathalie Samson; Jean-Paul Praud
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

3.  Thoracic shape changes in newborns due to their position.

Authors:  Serena de Gelidi; Andy Bardill; Nima Seifnaraghi; Yu Wu; Andreas Demosthenous; Marika Rahtu; Merja Kallio; Richard Bayford
Journal:  Sci Rep       Date:  2021-02-24       Impact factor: 4.379

Review 4.  Infant lung function testing in the intensive care unit.

Authors:  J Hammer; C J Newth
Journal:  Intensive Care Med       Date:  1995-09       Impact factor: 17.440

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.