Literature DB >> 31824167

Assessment Of Ambient-Noise Exposure Among Female Nurses In Surgical Cardiac Intensive Care Unit.

Safa A Alduais1, Khaled F Salama2.   

Abstract

PURPOSE: To measure noise levels in the Saud Albabtain Cardiac Center cardiac surgical intensive-care unit (CSICU) at different locations to find out the prevalence of noise-induced hearing loss among female nurses.
METHODS: Ambient CSICU noise was measured using a sound-level meter and personal noise dosimeter during morning and night shifts (12 hours each) for 30 days. An audiometry test and questionnaire were used to test nursing responses to noise levels.
RESULTS: Mean 12-hour average noise levels at the station during night shift were 60.3±7.1 dB(A) and inside rooms 62.48±8.02 dB(A). However, during morning shift 64.1±8.4 dB(A) in the rooms was recorded, while 68.8±8.2 dB(A) was recorded at the station, with a significant difference between the shifts (p<0.0001). ICU monitors recorded the highest noise-source levels of 82.7±5.3 dB(A). The lowest significant source was the suction machines, with an average of 67.1±12.5 dB(A). A significant correlation between decibel loss and nurse experience was observed.
CONCLUSION: Noise levels in the CSICU at Saud Albabtain Cardiac Center were higher than World Health Organization standards. CSICU nurses are exposed to noise levels that can affect their hearing capacity. Further research isneeded for effective medical device-alarm management.
© 2019 Alduais and Salama.

Entities:  

Keywords:  ambient noise; audiometry; hospital; intensive-care unit; nurses

Year:  2019        PMID: 31824167      PMCID: PMC6901058          DOI: 10.2147/JMDH.S222801

Source DB:  PubMed          Journal:  J Multidiscip Healthc        ISSN: 1178-2390


  16 in total

Review 1.  Noise pollution: a modem plague.

Authors:  Lisa Goines; Louis Hagler
Journal:  South Med J       Date:  2007-03       Impact factor: 0.954

2.  Assessment of noise environment in a major railway station in India.

Authors:  P Bandyopadhyay; S K Bhattacharya; S K Kashyap
Journal:  Ind Health       Date:  1994       Impact factor: 2.179

3.  Noise levels in an urban hospital and workers' subjective responses.

Authors:  M V Bayo; A M García; A García
Journal:  Arch Environ Health       Date:  1995 May-Jun

4.  ALARMED: adverse events in low-risk patients with chest pain receiving continuous electrocardiographic monitoring in the emergency department. A pilot study.

Authors:  Clare Atzema; Michael J Schull; Bjug Borgundvaag; Graham R D Slaughter; Cheong K Lee
Journal:  Am J Emerg Med       Date:  2006-01       Impact factor: 2.469

5.  Noise, stress, and annoyance in a pediatric intensive care unit.

Authors:  Wynne E Morrison; Ellen C Haas; Donald H Shaffner; Elizabeth S Garrett; James C Fackler
Journal:  Crit Care Med       Date:  2003-01       Impact factor: 7.598

6.  Noise pollution levels in the pediatric intensive care unit.

Authors:  Bree Kramer; Prashant Joshi; Christopher Heard
Journal:  J Crit Care       Date:  2016-07-09       Impact factor: 3.425

7.  Characterising the ambient sound environment for infants in intensive care wards.

Authors:  Helen Shoemark; Edward Harcourt; Sarah J Arnup; Rod W Hunt
Journal:  J Paediatr Child Health       Date:  2016-04-06       Impact factor: 1.954

8.  Reducing hospital noise: a review of medical device alarm management.

Authors:  Avinash Konkani; Barbara Oakley; Thomas J Bauld
Journal:  Biomed Instrum Technol       Date:  2012 Nov-Dec

9.  Associations of exposure to noise with physiological and psychological outcomes among post-cardiac surgery patients in ICUs.

Authors:  Suh-Meei Hsu; Wen-Je Ko; Wen-Chun Liao; Sheng-Jean Huang; Robert J Chen; Chung-Yi Li; Shiow-Li Hwang
Journal:  Clinics (Sao Paulo)       Date:  2010       Impact factor: 2.365

10.  Comparison of staff and family perceptions of causes of noise pollution in the Pediatric Intensive Care Unit and suggested intervention strategies.

Authors:  Harsheen Kaur; Gina M Rohlik; Michael E Nemergut; Sandeep Tripathi
Journal:  Noise Health       Date:  2016 Mar-Apr       Impact factor: 0.867

View more
  1 in total

1.  Assessment of video see-through smart glasses for augmented reality to support technicians during milking machine maintenance.

Authors:  Gabriele Sara; Giuseppe Todde; Maria Caria
Journal:  Sci Rep       Date:  2022-09-21       Impact factor: 4.996

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.