Literature DB >> 3182195

Scotopic threshold response (STR) of the human electroretinogram.

P A Sieving1, C Nino.   

Abstract

We recorded the human ERG using full-field stimuli at light intensities near absolute threshold to examine characteristics of the scotopic threshold response (STR). The human STR was seen below PII threshold and was the only component of the ERG evident near absolute rod psychophysical threshold. The human STR was detectable in the corneal ERG at stimulus intensities 0.6-1.0 log units above psychophysical threshold and had about a 2 log unit range to apparent saturation. Maximum STR amplitude was 12-20 microV. The STR latency ranged from 100-185 msec, depending on stimulus duration and intensity. The STR returned to baseline by 300 msec after onset, for very brief flashes, but it was prolonged with longer flashes. The spectral characteristics of the human STR matched rods and not cones. The STR followed Bloch's law and exhibited temporal integration for at least 80 msec. At 2.5-3 log units above visual threshold, corneal positive PII (b-wave and d.c. component) progressively obscured the negative STR. We propose that the human STR reflects post receptor processing in the retina. This is based on the similarity of the human STR to the STR of the cat and monkey, both of which originate at postreceptoral sites. Thus the human STR may find clinical use to evaluate the rod pathway in the proximal retina.

Entities:  

Mesh:

Year:  1988        PMID: 3182195

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  17 in total

1.  Electrically evoked electroretinograms and pupil responses in Argus II retinal implant wearers.

Authors:  H Christiaan Stronks; Michael P Barry; Gislin Dagnelie
Journal:  Doc Ophthalmol       Date:  2016-01-07       Impact factor: 2.379

2.  Isoflurane and ketamine:xylazine differentially affect intraocular pressure-associated scotopic threshold responses in Sprague-Dawley rats.

Authors:  Vivian Choh; Akshay Gurdita; Bingyao Tan; Yunwei Feng; Kostadinka Bizheva; Daphne L McCulloch; Karen M Joos
Journal:  Doc Ophthalmol       Date:  2017-06-21       Impact factor: 2.379

3.  Empiric limits of rod photocurrent component underlying a-wave response in the electroretinogram.

Authors:  M E Breton; D P Montzka
Journal:  Doc Ophthalmol       Date:  1992       Impact factor: 2.379

Review 4.  ERG components of negative polarity from the inner retina and the optic nerve response.

Authors:  Günter Niemeyer
Journal:  Doc Ophthalmol       Date:  2006-03-06       Impact factor: 2.379

5.  High correlation between absolute psychophysical threshold and the scotopic threshold response to the same stimulus.

Authors:  S L Graham
Journal:  Br J Ophthalmol       Date:  1991-10       Impact factor: 4.638

6.  Scotopic visual signaling in the mouse retina is modulated by high-affinity plasma membrane calcium extrusion.

Authors:  Jacque L Duncan; Haidong Yang; Thuy Doan; Robert S Silverstein; Gabe J Murphy; George Nune; Xiaorong Liu; David Copenhagen; Bruce L Tempel; Fred Rieke; David Krizaj
Journal:  J Neurosci       Date:  2006-07-05       Impact factor: 6.167

7.  Photopic ON- and OFF-pathway abnormalities in retinal dystrophies.

Authors:  P A Sieving
Journal:  Trans Am Ophthalmol Soc       Date:  1993

8.  The scotopic threshold response of the dark-adapted electroretinogram of the mouse.

Authors:  Shannon M Saszik; John G Robson; Laura J Frishman
Journal:  J Physiol       Date:  2002-09-15       Impact factor: 5.182

9.  Abnormalities of the scotopic threshold response correlated with gene mutation in X-linked retinoschisis and congenital stationary night blindness.

Authors:  Keith Bradshaw; Douglas Newman; Louise Allen; Anthony Moore
Journal:  Doc Ophthalmol       Date:  2003-09       Impact factor: 2.379

10.  Ganglion cell contributions to the rat full-field electroretinogram.

Authors:  Bang V Bui; Brad Fortune
Journal:  J Physiol       Date:  2003-10-24       Impact factor: 5.182

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.