Literature DB >> 31820743

Evaluation of dual electrode configurations for microchip electrophoresis used for voltammetric characterization of electroactive species.

Dulan B Gunasekara1, Manjula B Wijesinghe, Pann Pichetsurnthorn, Susan M Lunte.   

Abstract

Microchip electrophoresis coupled with amperometric detection is more popular than voltammetric detection due to the lower limits of detection that can be achieved. However, voltammetry provides additional information about the redox properties of the analyte that can be used for peak identification. In this paper, two dual electrode configurations for microchip electrophoresis are described and evaluated for obtaining voltammetric information using amperometry. The dual-series electrode configuration was first evaluated to generate current ratios in a single run by applying two different potentials to the working electrodes placed perpendicular to the separation channel. However, it was found that it is difficult to obtain realistic current ratios with this configuration, primarily due to the relative placement of electrodes with respect to the channel end of the simple-t microchip. Correction factors were needed to obtain current ratios similar to those that would be obtained for sequential injections at two different potentials using a single electrode. A second approach using a dual-channel chip with two parallel electrodes was then developed and evaluated for obtaining voltammetric identification. The newly developed microchip permitted the injection of same amount of sample into two unique separation channels, each with an electrode at a different detection potential. Migration times and current ratios for several biologically important molecules and potential interferences including nitrite, tyrosine, hydrogen peroxide, and azide were obtained and compared to the responses obtained for analytes found in macrophage cell lysates.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 31820743      PMCID: PMC7256876          DOI: 10.1039/c9an02112d

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  20 in total

1.  Dual-electrode electrochemical detection for poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips.

Authors:  R S Martin; A J Gawron; S M Lunte
Journal:  Anal Chem       Date:  2000-07-15       Impact factor: 6.986

2.  Microchip capillary electrophoresis coupled to sinusoidal voltammetry for the detection of native carbohydrates.

Authors:  Nicole E Hebert; Werner G Kuhr; Sara A Brazill
Journal:  Electrophoresis       Date:  2002-11       Impact factor: 3.535

Review 3.  Recent developments in electrochemical detection for microchip capillary electrophoresis.

Authors:  Walter R Vandaveer; Stephanie A Pasas-Farmer; David J Fischer; Celeste N Frankenfeld; Susan M Lunte
Journal:  Electrophoresis       Date:  2004-11       Impact factor: 3.535

4.  Nanoband electrode for high-performance in-channel amperometric detection in dual-channel microchip capillary electrophoresis.

Authors:  Chuanpin Chen; Wei Teng; Jong Hoon Hahn
Journal:  Electrophoresis       Date:  2011-03-17       Impact factor: 3.535

Review 5.  Food analysis on microchip electrophoresis: an updated review.

Authors:  Aida Martín; Diana Vilela; Alberto Escarpa
Journal:  Electrophoresis       Date:  2012-08       Impact factor: 3.535

6.  Determination of pterins in biological samples by liquid chromatography/electrochemistry with a dual-electrode detector.

Authors:  C E Lunte; P T Kissinger
Journal:  Anal Chem       Date:  1983-08       Impact factor: 6.986

7.  In-channel amperometric detection for microchip electrophoresis using a wireless isolated potentiostat.

Authors:  Dulan B Gunasekara; Matthew K Hulvey; Susan M Lunte
Journal:  Electrophoresis       Date:  2011-03-16       Impact factor: 3.535

8.  Microchip electrophoresis with amperometric detection method for profiling cellular nitrosative stress markers.

Authors:  Dulan B Gunasekara; Joseph M Siegel; Giuseppe Caruso; Matthew K Hulvey; Susan M Lunte
Journal:  Analyst       Date:  2014-07-07       Impact factor: 4.616

9.  Dual-channel method for interference-free in-channel amperometric detection in microchip capillary electrophoresis.

Authors:  Chuanpin Chen; Jong Hoon Hahn
Journal:  Anal Chem       Date:  2007-08-21       Impact factor: 6.986

10.  Tubular-wire dual electrode for detection of thiols and disulfides by capillary electrophoresis/electrochemistry.

Authors:  M Zhong; S M Lunte
Journal:  Anal Chem       Date:  1999-01-01       Impact factor: 6.986

View more
  1 in total

Review 1.  Biological applications of microchip electrophoresis with amperometric detection: in vivo monitoring and cell analysis.

Authors:  Kelci M Schilly; Shamal M Gunawardhana; Manjula B Wijesinghe; Susan M Lunte
Journal:  Anal Bioanal Chem       Date:  2020-04-28       Impact factor: 4.142

  1 in total