Metal Ion Release after Hip and Knee Arthroplasty - Causes, Biological Effects and Diagnostics.

Jörg Lützner1, Klaus-Peter Günther1, Anne Postler1, Michael Morlock2.   

Abstract

All metal implants in human bodies corrode which results in metal ions release. This is not necessarily a problem and represents for most patients no hazard. However, if a critical metal ion concentration is exceeded, local or rarely systemic problems can occur. This article summarizes the mechanisms of metal ion release and its clinical consequences. Several situations can result in increased metal ion release: metal-on-metal hip arthroplasties with increased wear, increased micromotion at taper interfaces, direct metal-metal contact (polyethylene wear, impingement), erroneously used metal heads after ceramic head fracture. Possible problems are in most cases located close to the concerned joint. Furthermore, there are reports about toxic damage to several organs. Most of these reports refer to erroneously used metal heads in revisions after a broken ceramic head. There is currently no evidence of carcinogenic or teratogenic effects of implants but data is not sufficient to exclude possible effects. Cobalt and chromium blood levels (favorably in whole blood) should be measured in patients with suspected elevated metal ions. According to current knowledge levels below 2 µg/l seem to be uncritical, levels between 2 and 7 µg/l are considered borderline with unknown biological consequences and levels above 7 µg/l indicate a local problem which should be further diagnosed. Metal ion levels always need to be interpreted together with clinical symptoms and imaging results. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Year:  2019        PMID: 31820432     DOI: 10.1055/a-0929-8121

Source DB:  PubMed          Journal:  Z Orthop Unfall        ISSN: 1864-6697            Impact factor:   0.923


  2 in total

1.  [The use of knee prostheses with a hypoallergenic coating is safe in the medium term : A randomized controlled study].

Authors:  Anne Postler; Franziska Beyer; Cornelia Lützner; Eric Tille; Jörg Lützner
Journal:  Orthopadie (Heidelb)       Date:  2021-11-03

2.  Retrieval Analysis of Modern Knee Tumor Megaendoprosthesis Shows Considerable Volumetric Metal Wear Generated at the Rotating Hinge.

Authors:  Therese Bormann; Sebastian Jäger; J Philippe Kretzer; Laura Nebel; Lucas Clarius; Georg Omlor; Rudi Bitsch; Burkhard Lehner
Journal:  Materials (Basel)       Date:  2020-03-26       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.