Literature DB >> 31814605

Establishment of a Multiplex Real-Time TaqMan-MGB Polymerase Chain Reaction (PCR) Method for the Simultaneous Detection of Three Animal Chlamydia Species.

Fuping Nie1,2, Qian Gong2, Jun Yang2, Cunxian Xi2, Yu Wang2, Guomin Wang2, Lei Zhang2, Xianliang Li2, Danqun Huo1, Changjun Hou1.   

Abstract

BACKGROUND Chlamydiae are spread globally and cause infectious diseases in both humans and animals. The existing detection methods for this disease have numerous shortcomings, including low sensitivity, time consuming procedures, and high contamination vulnerability. MATERIAL AND METHODS To overcome shortcomings for detecting animal chlamydiosis, a multiplex quantitative polymerase chain reaction (PCR) assay was established for simultaneously detecting and differentiating 3 Chlamydia species (C. pecorum, C. abortus, and C. psittaci) by real time PCR based on TaqMan-MGB technology. RESULTS The limit of detection was 20.2 copies/µL for Chlamydophila (Cp.) abortus, 30.8 copies/µL for Cp. pecorum, and 16 copies/µL for Cp. psittaci. This method has good repeatability and stability as coefficients of variation range from 0.04% to 1.38%. Furthermore, compared with OIE (World Organization for Animal Health) recommended PCR assay and previously reported animal chlamydia shell PCR, this multiplex PCR assay demonstrated 99% concordance in detecting clinical samples of porcine nasal swabs and vaginal swabs. CONCLUSIONS The novel established method in this study was able to detect 3 types of Chlamydia species simultaneously, and had high sensitivity, strong specificity, and good stability. It provided a rapid, reliable, and convenient method for epidemiological and clinical diagnosis of chlamydiosis in animals.

Entities:  

Mesh:

Year:  2019        PMID: 31814605      PMCID: PMC6921693          DOI: 10.12659/MSM.918344

Source DB:  PubMed          Journal:  Med Sci Monit        ISSN: 1234-1010


Background

Chlamydiae are spread globally and cause diseases in humans and animals. They may provoke ocular, pulmonary, genital, articular, and intestinal illness [1]. Outbreaks of chlamydiosis cause considerable economic damage for health care system and agriculture [2]. According to current classification system, the Chlamydia family is divided into the genera Chlamydia (C.) and Chlamydophila (Cp.). Chlamydia includes C. trachomatis, C. suis, C. muridarum, and C. caviae. Chlamydophila includes Cp. abortus, Cp. felis, Cp. pecorum, Cp. pneumoniae, and Cp. psittaci [3-5]. All Chlamydia species are potential zoonotic pathogens, and especially Cp. pecorum, Cp. Abortus, and Cp. psittaci pose the greatest threat to livestock breeding [1]. Besides, Cp. psittaci and Cp. abortus are classified as class B diseases according to a previously published study [3], therefore, quarantine inspection for Chlamydia is inter alia recommended in the course of international trade. Cp. pecorum infected animals were found to suffer from intermittent encephalomyelitis, multiple arthritis, pneumonia, enteritis, vaginitis, and endometritis [4-6]. Pigs infected with Cp. pecorum suffer pneumonia, polyarthritis, pleurisy, pericarditis and abortion [7-9]. C. trachomatis and Cp. pecorum infections may be the main reasons for porcine chlamydial abortion [10]. Cp. abortus, known as ovine enzootic abortion (OEA), is mainly confined to the epithelial cells of reproductive tract. Cp. abortus infection usually results in damage to the reproductive tract, leading to miscarriage dams, stillbirth, low tire, sire orchitis, urethritis, and inflammation of the glans and the foreskin as characterized by chronic contagious disease [11-13]. In the United Kingdom, Longbottom et al. [12] showed that Cp. abortus infection causes up to 50% of all ovine abortions. Cp. psittaci is a type of intracellular parasitic zoonosis pathogen, which has a strong tendency to infect birds, poultry, and livestock. Through contact or inhalation of infectious secretions and excretions of poultry, humans have become infected, causing atypical pneumonia, sepsis, conjunctivitis, myocarditis, meningitis, etc. [1,14,15]. It thus was designated as a World Organization for Animal Health (OIE)-listed notifiable disease in 2018 [16]. Therefore, there is an urgent need to develop a rapid, reliable method for sensitive and specific detection of Chlamydia in animals. Currently, the diagnostic methods for detection of Chlamydia including enzyme linked immunosorbent assay (ELISA), indirect hemagglutination test (IHA), complement fixation test (CFT), and polymerase chain reaction (PCR) [17,18]. Isolation of the pathogen is still considered to be the gold standard for diagnosis of chlamydiosis, however, the sensitivity is relatively low. Moreover, chlamydia-mycoplasma contamination is a common problem in cell culture [19,20]. Mukherjee et al. [21], using PCR and enzyme immune assay (EIA), compared the level of Chlamydia by direct detection of PCR and found it had a high positive rate and good sensitivity. Khan et al. [22] used RT-PCR detection of Chlamydia in children with bronchitis to show that this method was superior to conventional PCR. Opota et al. [23] improved the molecular diagnosis for the C. abortus and C. psittaci infection using the species-specific duplex RT-PCR assay. However, the use of conventional PCR imposes greater limitations, such as ease of contamination, time-consuming, and low sensitivity makes diagnostic testing of chlamydial zoonosis pathogens unsatisfactory. Thus, it is necessary to improve diagnostic methods of Chlamydia detection.

Material and Methods

Chlamydia strains

C. pneumoniae (ATCC 53592), C. psittaci (ATCC), Cp. abortus (ATCC 656), Cp. pecorum (ATCC 1575), C. muridarum (ATCC VR123), C. suis (ATCC VR1474), and C. trachomatis (ATCC VR878) were purchased from American Type Culture Collection (ATCC). Cp. abortus, Cp. pecorum, and C. psittaci were used as positive controls. Other related strains of Chlamydia were used for optimizing multiple quantitative PCR conditions.

Sample collection and DNA extraction

The nasopharyngeal swabs (n=246) and vaginal swabs (n=960) were collected from animals in farm with an abortion history. The samples were stored at −80°C until usage. DNA was extracted from clinical samples or cell culture supernatants using the QIAamp MinElute Virus Spin Kit (Qiagen, Hilden) according to manufacturer’s instructions. DNA was eluted in 50 μL of elution buffer and kept at −80°C until further analysis. The quality and concentrations of DNAs were determined by spectrophotometer (BioMATE3, Thermo Scientific, Wilmington, DE, USA).

Primers and probes

The primers and probe for this experiment were designed based on the sequences of major outer membrane protein of chlamydial (including Cp. pneumoniae, Cp. abortus, Cp. pecorum, C. muridarum, C. suis, C. trachomatis, Cp. psittaci, Cp. Felis, C. caviae, and Cp. abortus), The sequences of Chlamydia major outer membrane protein were downloaded from the GenBank and aligned by MEGA 5.05 software. The conservative areas were used to design a pair of ordinary PCR primers (used in the construction of a positive quality) by using Primer Express 3.0 software. In addition, 3 pairs of primers and specific probes of individual Chlamydia were designed for multiplex PCR. The primer and probe sequences were listed in Table 1.
Table 1

Sequence of primers and probes.

SpeciesPrimers and probesNucleotide sequence (5′-3′)Product length (bp)
ChlamydiaceaeOMP FwCTCCTTRCAAGCYYTGCCTGT1100
OMP RevGTGAGCWGCTCTTTCRTYRATTAARCG
Cp. abortusAbortus FwGCATGGGTGCAGTTCCTACA63
Abortus RevTGGGTCTATCCGTAGGAGTTTTG
Abortus probe5′NED-ACCGCAGCAGCTAA-MGB3′
Cp. pecorumPecorum FwGCAGAGCCAAGTTTATTAATTG125
Pecorum RevTAGCGCAAGGATCACATG
Pecorum probe5′FAM-ATCTCCTGACATACCTTC-MGB3′
Cp. psittaciPsittaci FwGCAACTCCTACGCAGGCTACA67
Psittaci RevTCGGTCTGCCATTTGCTTCT
Psittaci probe5′VIC-AACGCAAGTAATACTAATCA-MGB3′

Plasmids

Three specific targets of each Chlamydia were amplified with 3 pairs of primers (Table 1). Meanwhile, a most abundant chlamydial protein, major outer membrane protein (MOMP), was also detected (Table 1). The produced DNAs were extracted with agarose gels using Gel Extraction Kit (Cat. No. E.Z.N.A.TM, Omega Bio-Tek, Doraville, GA, USA), according to instructions of manufacturer. The amplified DNA fragments were sub-cloned into pMD19-T plasmid (Cat. NO. D102A, Takara, Dalian, China) according to manufacturer’s protocol. Then, the re-combined plasmids were transfected into the Escherichia coli. The MiniBEST Plasmid Extraction Kit (Cat. NO. 9760, Takara, Dalian, China) was employed to isolate the plasmids containing targeting genes. Subsequently, the targeting DNAs in sub-cloned plasmids were sequenced and analyzed with DNASTAR software 4.0 (DNASTAR, Madison, WI, USA). Eventually, the gene sequences were compared with the associated sequencing data recorded in the GenBank, to identity the cloned DNA fragments. Measuring the concentration of each plasmid and calculating its copy number, the positive plasmid copy number (copies/μL)=plasmid concentration×10−9×diluted multiples×6.02×1023)/(660 Dalton/bases x bases) to make the copy number positive. The copy numbers of Cp. abortus, Cp. psittaci, and Cp. pecorum were 2.02×109 copies/μL, 1.6×109 copies/μL and 3.08×109 copies/μL respectively. The resultant recombinant plasmids contain the fragment of each Chlamydia strains were stored at −80°C and used as positive controls plasmids for subsequent PCR optimization.

Multiplex quantitative PCR

The constructed plasmids carrying the targeting DNA fragments were employed to optimize the multiple real-time PCR, as the PCR templates. The real-time PCR assay conditions were optimized by varying various single parameters and locking the other parameters. Based on findings of orthogonal experiments or tests selecting optimal primers proportion, we also optimized the appropriate effects of annealing-temperature and the other conditions on the PCR assay. The optimized real-time PCR reaction (20 μL) was comprised of 1×Premix Ex Taq (Probe qPCR) (TaKaRa), 0.4 μmol/L Cp. abortus primers, 0.2 μmol/L Cp. abortus probe, 0.2 μmol/L Cp. pecorum primers, 0.05 μmol/L Cp. pecorum probe, 0.6 μmol/L Cp. psittaci primers, 0.1 μmol/L Cp. psittaci probe, and 2 μmol/L of DNA extract. The following thermal-cycling conditions were applied: 95°C for 30 seconds, following with 40 cycles in 2 steps: a) 95°C for 5 seconds and b) 58°C for 34 seconds. The fluorescence levels were measured at the end of each cycle. Three strains of Chlamydia were mixed according to their individual optimized reaction systems: sterile water was added to bulk the volume to 20 μL. PCR optimization was carried out by modulated the concentration of primers, probe and cycling conditions, The multiplex PCR results were generated by following the PCR protocols described as follows: 1×premix Ex TagTm, 0.4 μmol/L Cp. abortus primers, 0.2 μmol/L Cp. abortus probe, 0.2 μmol/L Cp. pecorum primers, 0.05 μmol/L Cp. pecorum probe, 0.6 μmol/L Cp. psittaci primers, 0.1 μmol/L Cp. psittaci probe, and 1 μL of extracted plasmid DNA. Cycling conditions were as follows: 95°C for 30 seconds following with 40 cycles composing of 95°C for 5 seconds, and then 58°C for 34 seconds.

Diagnostic specificity and sensitivity

For specificity testing, plasmid contains of Cp. pecorum, C. muridarum, C. trachomati, Cp. psittaci, Cp. abortus, Cp. pneumoniae, and C. suis were used as PCR templates separately. The detection limit was determined using decimal serial dilutions of purified recombinant plasmid which contains chlamydial segments as template in multiplex PCR reaction (Cp. abortus 2.02×109 copies/μL to 2.02 copies/μL, Cp. psittaci 1.6×109 copies/μL to 1.6 copies/μL, Cp. pecorum 3.08×109 copies/μL to 3.08 copies/μL).

Standard curve, repeatability and stability assessment

To calculate the standard curve of each gene, serially diluted concentrations of Cp. abortus, Cp. psittaci or Cp. pecorum recombinant plasmids were used as template in multiplex real-time PCR. The repeatability and stability of multiplex real-time PCR was evaluated by several cycle of amplification in serial dilutions (106, 105, 104 copies/μL) for all of the aforementioned plasmids. All the reactions were run in triplicates.

Detection of clinical samples

Clinical specimens were employed to assess efficacy of the established multiplex real-time PCR assay. The specimens were 660 porcine nasopharyngeal swabs and 960 vaginal swabs collected from Chongqing at the same time. Here, multiplex real-time PCR assay established was referred as Test 1, while OIE recommended fluorescence quantitative PCR [16] was referred as Test 2 and reported animal chlamydia shell PCR was referred as Test 3 [23]. The detection methods established in this study detected 17 positive samples from 1620 (660 porcine nasopharyngeal swabs and 960 vaginal swabs) clinical samples and could distinguish the type of infection. Moreover, sequencing of the 17 chlamydial positive samples (Takara Biotechnology (Dalian) Co., Ltd., China) were used to confirm the PCR results.

Results

Analysis of specificity of multiplex quantitative PCR

To assess the specificity co-amplification of chlamydial strains using the established multiplex real-time PCR assay, a series of the different concentrations of Cp. pecorum, C. muridarum, C. trachomati, Cp. psittaci, Cp. abortus, Cp. pneumoniae, and C. suis DNA were co-amplified. Cp. psittaci, Cp. abortus, and Cp. pecorum were amplified in presence of other chlamydial strains. The results showed high specificity and no cross-reactivity with other viruses. The crossing threshold (Ct) values were locked for specific target DNA when the other strains were co-amplified (Figure 1).
Figure 1

Multiplex polymerase chain reaction assay specific identification results.

Analysis of sensitivity of multiplex quantitative PCR

To assess the sensitivity of established multiplex real-time PCR assay, limit of the detection (LOD) was evaluated for Cp. psittaci, Cp. abortus, and Cp. pecorum using a 10-fold dilution of the plasmid standards. The LOD for Cp. abortus was 2.02×10 copies/μL, the LOD for Cp. pecorum was 3.08×10 copies/μL and the LOD of Cp. psittaci was 1.6×10 copies/μL.

Linear range, intra-and inter-run variation

Validation experiments were performed to determine the amplification efficiencies of 3 chlamydial strains by developed multiplex quantitative PCRs. Briefly, serially diluted plasmid was used as template DNA in the multiplex amplification. A good linear regression plot was found by plotting the Cq-values against the values of log10 DNA for the 3 curves and the corresponding standard curve showed that each of the 3 chlamydial strains had a regression factor R2 of 0.999 and efficiency ranging from 99.1% to 103.2% (Figure 2).
Figure 2

Multiplex real-time quantitative polymerase chain reaction standard curve.

Reproducibility test of multiple fluorescence quantitative PCR

In order to assess repeatability, a serial 10-fold dilution (from 106 copies/μL to 104 copies/μL) of 3 chlamydial segments containing plasmids were used as PCR templates. Experiments were carried out in triplicate on 3 independent PCR reactions. The inter- and intra-batch coefficients of variation were range from 0.04% to 1.38% (Table 2). The results indicated the validity of the developed multiplex quantitative PCR.
Table 2

Intra-assay and inter-assay reproducibility test of multiple fluorescence quantitative PCR.

NamesStandard dilutionInter-coefficient of variationIntra-coefficient of variation
MeanSDCV (%)MeanSDCV (%)
Cab100018.10940.06250.3518.33800.01730.09
Cab1000021.33360.10340.4821.47490.00570.03
Cab10000024.51730.14290.5824.66500.15200.62
Cps100019.75220.13490.6819.77100.16210.82
Cps1000023.01970.02790.1223.11840.00870.04
Cps10000026.07500.30011.1526.04340.35951.38
Cpe100017.08970.01940.1117.11130.01570.09
Cpe1000020.17440.08900.4420.17330.08650.43
Cpe10000023.74970.22110.9324.00500.01050.04

Diagnostic application of the established multiplex real time PCR on clinical specimens

To assess reliability of established multiplex real-time PCR assay for diagnosing the chlamydial pathogens, performance of our developed assay was compared to those of the OIE recommended [16] and a previously reported reference method [23]. The 3 assays mentioned were used to test 660 porcine nasopharyngeal swabs and 960 vaginal swab samples. By using the OIE recommended PCR method, chlamydial infection was diagnosed with a positive rate of 20.9% in nasopharyngeal swabs and 25.8% in vaginal swabs. The positive rate was 19.5% and 24.9% respectively with previously reported nested PCR assay (Figure 3, Table 3). And with the multiplex PCR assay we developed in this study, the chlamydial pathogens of interest were detected in 20.3% of nasopharyngeal swabs and 25.6% of vaginal swabs (Figure 3, Table 4). The detection positive rates of multiplex quantitative PCR developed in this study displayed 99% identification agreement with the OIE recommendations and slightly higher than the nested PCR methods.
Figure 3

Comparison of positive testing rates of the 3 detection methods.

Table 3

Comparison of the results from developed multiplex realtime PCR and reference PCRs for detection of Cp. abortus, Cp. pecorum, and C. psittaci in clinical specimens.

TypeDetection methods
Test 1Test 2 [16]Test 3 [23]
Nasopharyngeal swabs134/660 (20.3%)138/660 (20.9%)129/660 (19.5%)
Vaginal swabs246/960 (25.6%)248/960 (25.8%)239/960 (24.9%)
Total380/1620 (23.4%)386/1620 (23.8%)368/1620 (22.7%)
Table 4

Multiple types of infection: quantitative PCR positive samples.

Type of infectionPositive (a)The positive rate (%)
Cpe/Cps/Cab15.88
Cpe/Cab15.88
Cpe/Cps211.76
Cps/Cab15.88
Cab423.53
Cps317.64
Cpe529.41
Total17100.00
Therefore, the application of multiplex quantitative PCR assay was comparable with the reference PCRs and has high levels of analytical and diagnostic accuracy of detection with suspected clinical specimens.

Discussion

The traditional detection methods of Chlamydia infection mainly include serological experiments, trace immunofluorescence methods and ELSA. However, the cross-reaction of immune-detecting method thus engendering a lack of specificity and sensitivity. PCR is a sensitive, specific, and stable nucleic acid amplification technique. Currently, there are enormous methods of PCR for testing for Chlamydia infection. At present, the conventional PCR detection methods are mainly focused on the major outer membrane protein gene 16S/23S rRNA, and some of them performed well as detection methods for Chlamydia [19,24,25]. Condon designed a PCR method according to the chlamydial 16S rRNA and compared with a serological method and a pathogen separation method and found that PCR method have high sensitivity and strong specificity [26]. However, in this study, we detected the abundantly expressed chlamydial protein, MOMP, but not the chlamydial 16S/32S rRNA, for detecting Chlamydia infection. Meanwhile, the MOMP gene is usually attenuated in the chronic, persistent chlamydial infections, which has not been considered in this study and represented. In the following study, we would exclude the clinical specimens with the chronic, persistent chlamydial infections. Kaltenbock and colleagues developed a nested PCR assay, and tested 407 specimens from several host animals with various clinical conditions to evaluate their genus-specific amplification [27]. Real-time PCR developed in earlier studies mainly designed for a certain chlamydial strain [28,29]. Note that animal chlamydiosis may be caused by mixed infection. Several multiplex real-time PCR assays had been developed during the past few years. Pantchev and colleagues developed real-time PCR tests for species-specific detection of C. psittaci and C. abortus [30]. Rodolakis et al. [31] reported that their multiplex PCR assay could simultaneous differential detection of Cp. abortus, Cp. pecorum, and Coxiella burnetii from aborted ruminant’s clinical samples. In this study, for the first time we developed and optimized a method of TaqMan-MGB based fluorescence PCR that can simultaneously detect the most important chlamydial species Cp. pecorum, Cp. abortus, and Cp. psittaci in a single reaction. The probe was an MGB probe and its quenching was a kind of fluorescence quenching of the group. It will not produce fluorescence, and thus the quenching efficiency can reach a high level. At the same time, it can reduce the fluorescence background signal intensity of the PCR reaction. On the MGB probe there are special chemical groups known as small groove binders. The combination of these can makes the Tm value increased 10-fold and it greatly increased the specificity of the amplification reaction. Compared to conventional PCR methods, multiple fluorescent quantitative PCR developed by this study was more sensitive and accurate [27]. The LOD of the multiplex PCR was 2.02×10, 3.08×10, and 1.6×10 for Cp. Abortus, Cp. pecorum, and Cp. psittaci, respectively. Although a previous study [23] also developed a TaqMan PCR method to detect the Cp. abortus and Cp. psittaci, with a higher sensitivity and specificity compared with the present results which did not detect Cp. pecorum with a higher efficacy. Although, the multiple fluorescent quantitative PCR established in this study had a high sensitivity. In addition, the CV value of inter- and intra-batch ranged from 0.04% to 1.38% which indicated good stability and repeatability of the multiplex PCR assay. However, this result did not evaluate the sensitivity and specificity of our established multiplex PCR method using the receiver operating characteristic (ROC) curve against the standard, which was a limitation of our study. Meanwhile, previously published studies [32,33] also demonstrated higher sensitivity, even higher than 97%, and higher specificity even higher than 90%. However, in our study, we assigned the LOD to represent the sensitivity of our multiplex real-time PCR, illustrating sensitivity of Cp. abortus, Cp. pecorum, and Cp. psittaci with 2.02×10 copies/μL, 3.08×10 copies/μL, and 1.6×10 copies/μL, respectively. Actually, the LOD represented sensitivities even achieve results up to 100%, therefore, the sensitivity of our established PCR assay was higher compared to previous studies [32,33]. For the specificity of the established PCR assay, although we have not quantified the value of specificity, and there was no cross-reactivity with other viruses, therefore, our results showed high specificity for diagnosing the Cp. abortus, Cp. pecorum, and Cp. psittaci. Finally, we tested porcine swab samples and compared the results with that of OIE recommendations and published animal Chlamydia nested PCR methods to assess application of multiplex quantitative PCR assay. The performances were in accordance with recommendations of the OIE and better than that of conventional PCR assay. We found that OIE ranks PCR detection methods as higher than multiple fluorescence quantitative PCR with regard detection rates because the OIE recommends PCR detection method as able to detect all chlamydial strains in animals while multiple fluorescence quantitative PCR can detect only 3 strains. Compared with the method of multiple fluorescent quantitative PCR for animal chlamydia shell PCR, we found that the detection accuracy of multiple fluorescence quantitative PCR was higher. The method of multiple fluorescent quantitative PCR established in this study had a high sensitivity and specificity. In addition, the most important advantage of this method was its ability to distinguish 3 different strains of Chlamydia. Moreover, the PCR method reported by Everett, could only detect Chlamydiaceae family not species-specific test, subsequent sequencing of PCR product is needed in order to identify the species [34]. While the multiplex method developed in this study could detect and differentiate the 3 most harmful Chlamydia species and capable of detecting mixed infections. Actually, one PCR method might bring different diagnosing results of chlamydiosis for different species, such as human and other animal species [35]. A few established PCR assays are suitable for the chlamydiosis of humans, while some established PCR assays are suitable for the chlamydiosis of animals. However, in this study, we only identified the diagnosis efficacy of established multiplex real-time PCR for chlamydiosis of animals, which was a limitation of this study.

Conclusions

The multiplex real-time PCR method was found to be time saving, highly sensitive and specific and should be suitable for routine diagnostic testing. The fast diagnosis of animal chlamydiosis could thus provide a meaningful contribution to prevention and clinical treatment of animal Chlamydia infection in the future.
  33 in total

1.  Use of synthetic antigens improves detection by enzyme-linked immunosorbent assay of antibodies against abortigenic Chlamydia psittaci in ruminants.

Authors:  B Kaltenboeck; D Heard; F J DeGraves; N Schmeer
Journal:  J Clin Microbiol       Date:  1997-09       Impact factor: 5.948

2.  Rapid detection of the Chlamydiaceae and other families in the order Chlamydiales: three PCR tests.

Authors:  K D Everett; L J Hornung; A A Andersen
Journal:  J Clin Microbiol       Date:  1999-03       Impact factor: 5.948

3.  Application of a nested, multiplex PCR to psittacosis outbreaks.

Authors:  T O Messmer; S K Skelton; J F Moroney; H Daugharty; B S Fields
Journal:  J Clin Microbiol       Date:  1997-08       Impact factor: 5.948

Review 4.  [Microbiological diagnosis of infections due to Chlamydia spp. and related species].

Authors:  Mario Rodríguez-Domínguez; Sara Sanbonmatsu; Jesús Salinas; Roberto Alonso; José Gutiérrez; Juan Carlos Galán
Journal:  Enferm Infecc Microbiol Clin       Date:  2013-03-22       Impact factor: 1.731

Review 5.  Chlamydophila psittaci infections in birds: a review with emphasis on zoonotic consequences.

Authors:  Taher Harkinezhad; Tom Geens; Daisy Vanrompay
Journal:  Vet Microbiol       Date:  2008-09-16       Impact factor: 3.293

Review 6.  Chlamydiaceae and chlamydial infections in sheep or goats.

Authors:  A Rodolakis; K Laroucau
Journal:  Vet Microbiol       Date:  2015-07-20       Impact factor: 3.293

Review 7.  Zoonotic Chlamydophila psittaci infections from a clinical perspective.

Authors:  D S A Beeckman; D C G Vanrompay
Journal:  Clin Microbiol Infect       Date:  2009-01       Impact factor: 8.067

8.  Chlamydia prevalence in Polish pig herds.

Authors:  K Rypuła; A Kumala; K Płoneczka-Janeczko; E Karuga-Kuźniewska; K Dudek; P Chorbiński
Journal:  Epidemiol Infect       Date:  2016-05-13       Impact factor: 4.434

9.  Development and validation of a real-time PCR for Chlamydia suis diagnosis in swine and humans.

Authors:  Kristien De Puysseleyr; Leentje De Puysseleyr; Julie Geldhof; Eric Cox; Daisy Vanrompay
Journal:  PLoS One       Date:  2014-05-09       Impact factor: 3.240

10.  The development of a multiplex real-time PCR for the detection of herpes simplex virus 1 and 2, varizella zoster virus, adenovirus and Chlamydia trachomatis from eye swabs.

Authors:  Susan Bennett; William F Carman; Rory N Gunson
Journal:  J Virol Methods       Date:  2012-09-18       Impact factor: 2.014

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.