Evaluation of the MR and pathology characteristics immediately following percutaneous MR-guided microwave ablation in a rabbit kidney VX2 tumor implantation model.

Hao Li1, Zhengyu Lin1, Jie Chen1, Rui Guo1.   

Abstract

Purpose: This study aimed to evaluate the immediate efficacy of magnetic resonance (MR)-guided microwave ablation (MWA) in rabbit kidneys implanted with VX2 tumors.Materials and methods: MR-guided MWA was performed in eight VX2 tumor-bearing rabbits. MR images after ablation were obtained and analyzed. The differences between the tissue specimens and MR images obtained after ablation were compared.
Results: On the three-dimensional volumetric interpolated breath-hold T1-weighted (3D-VIBE-T1WI) sequence, a low signal intensity indicated the primary tumor at the center of the ablation area, which was surrounded by a peripheral high-signal area. The signal for the primary tumor in the fast spin-turbo spin-echo T2-weighted (FS-TSE-T2WI) sequence was lower than before, and the ablation zone showed a low signal that completely covered the primary tumor. There was no significant difference in volume among the low-signal areas of the primary tumor on FS-TSE-T2WI before MWA, the central low-signal area on 3D-VIBE-T1WI after MWA, and the tumor coagulation necrosis area on the tissue specimens (p > 0.05). No significant difference was found in the volume of ablation zones among the tissue specimens, the high-signal area around the lesion on the 3D-VIBE-T1WI sequence, and the low-signal area covering the lesion on the FS-TSE-T2WI sequence (p > 0.05).
Conclusion: Magnetic resonance imaging (MRI) is an effective method for immediate efficacy evaluation of rabbit renal VX2 tumors after MWA and can serve as a valuable reference for the clinical assessment of post-ablative renal tumors.

Entities:  

Keywords:  Magnetic resonance imaging; VX2; microwave ablation; pathological conditions; renal tumor

Mesh:

Year:  2019        PMID: 31814458     DOI: 10.1080/02656736.2019.1687944

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  2 in total

1.  MR-Guided Microwave Ablation for Lung Malignant Tumor: A Single Center Prospective Study.

Authors:  Ruixiang Lin; Yan Fang; Jin Chen; QingFeng Lin; Jian Chen; Yuan Yan; Jie Chen; Zhengyu Lin
Journal:  Front Oncol       Date:  2022-04-27       Impact factor: 5.738

2.  Microwave ablation therapy assisted by artificial pneumothorax and artificial hydrothorax for lung cancer adjacent to the vital organs.

Authors:  Jian Chen; Liqin Qi; Jin Chen; Qingfeng Lin; Yuan Yan; Jie Chen; Zhengyu Lin
Journal:  Front Oncol       Date:  2022-08-23       Impact factor: 5.738