Literature DB >> 31814313

Development of highly reliable SERS-active photonic crystal fiber probe and its application in the detection of ovarian cancer biomarker in cyst fluid.

Flavien Beffara1,2, Jayakumar Perumal1, Aniza Puteri Mahyuddin3, Mahesh Choolani3, Saif A Khan4, Jean-Louis Auguste2, Sylvain Vedraine2, Georges Humbert2, U S Dinish1, Malini Olivo1.   

Abstract

Conventionally Surface-enhanced Raman spectroscopy (SERS) is realized by adsorbing analytes onto nano-roughened planar substrate coated with noble metals (silver or gold) or their colloidal nanoparticles (NPs). Nanoscale irregularities in such substrates/NPs could lead to SERS sensors with poor reproducibility and repeatability. Herein, we demonstrate a suspended core photonic crystal fiber (PCF) based SERS sensor with extremely high reproducibility and repeatability in measurement with a relative SD of only 1.5% and 4.6%, respectively, which makes it more reliable than any existing SERS sensor platforms. In addition, our platform could improve the detection sensitivity owing to the increased interaction area between the guided light and the analyte, which is incorporated into the holes that runs along the length of the PCF. Numerical calculation established the significance of the interplay between light coupling efficiency and evanescent field distribution, which could eventually determine the sensitivity and reliability of the developed SERS active-PCF sensor. As a proof of concept, using this sensor, we demonstrated the detection of haptoglobin, a biomarker for ovarian cancer, contained within the ovarian cyst fluid, which facilitated in differentiating the stages of cancer. We envision that with necessary refinements, this platform could potentially be translated as a next-generation highly sensitive SERS-active opto-fluidic biopsy needle for the detection of biomarkers in body fluids.
© 2019 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  biopsy needle; ovarian cancer; photonic crystal fiber; protein sensing; reproducibility and repeatability in measurement; surface-enhanced Raman scattering

Mesh:

Substances:

Year:  2019        PMID: 31814313     DOI: 10.1002/jbio.201960120

Source DB:  PubMed          Journal:  J Biophotonics        ISSN: 1864-063X            Impact factor:   3.207


  1 in total

1.  Terahertz Plasmonic Sensor Based on Metal-Insulator Composite Woven-Wire Mesh.

Authors:  Ja-Yu Lu; Po-Lun Chen; Borwen You
Journal:  Biosensors (Basel)       Date:  2022-08-23
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.